KEMA Tested & ISO 9001/14001 Certified Manufacturing| Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

Mainland China

Mainland China中文

United States

United StatesEnglish

France

FranceFrançais

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Spec & Selection Studio
  • Electromagnetic PT vs. Capacitive CVT: Selection Guide for 110kV–500kV Substations
  • Understanding IEC 61869-3: Accuracy Classes, Burdens, and Temperature Rise Limits
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
High Voltage Equipment Directory

Voltage & Current Transformers

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

Loading products...
Category2
Voltage
Showing 382 Potential Transformer models
JDZW-10 6GY Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV
10kV/6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZW-10-6GY

Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV

Outdoor single-phase epoxy resin casting voltage transformer, 10kV/6kV rated, used for voltage measurement and protection in power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Features epoxy resin casting construction, good weather resistance, anti-ultraviolet, suitable for outdoor installation. Available with or without primary fuse options. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specifications.

Accuracy Class0.2/0.5/1.0
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869 / GB/T 20840
View Specs
JLSZV8-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JLSZV8-10W

Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV

Outdoor three-phase epoxy resin casting combined transformer current + voltage integrated, 10kV rated, for metering and protection in three-phase power distribution systems. Complies with GB/T 17201 standard. Epoxy resin construction, good weather resistance, anti-UV, pollution class IV, suitable for outdoor installation. Integrated CT and VT design, compact structure. Customizable ratios and accuracy classes.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 17201
View Specs
JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JLSZV6-10W

Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV

Outdoor three-phase epoxy resin casting combined transformer current + voltage integrated, 10kV rated, for metering and protection in three-phase power distribution systems. Complies with GB/T 17201 standard. Epoxy resin construction, good weather resistance, anti-UV, pollution class IV, suitable for outdoor installation. Integrated CT and VT design, compact structure. Customizable ratios and accuracy classes.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 17201
View Specs
JDZXF19-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF19-10-6G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 60VA / 100VA
View Specs
JSZV18-6DR1 Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV18-6DR1

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:90kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZXF19-10-6G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF19-10-6G1

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/0.2/3P(6P),0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 50VA / 100VA
View Specs
JDZ51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ51-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden75VA / 150VA / 300VA
View Specs
JDZXF51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF51-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 40VA / 100VA
View Specs
JSZY18-6FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-6FR

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:125kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZV19-6R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV19-6R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin insulated voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:72kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding types available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZV15-10R Indoor Three-phase Metal ArmouReddish  Brown Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV15-10R

Indoor Three-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer

Indoor three-phase metal armouReddish Brown epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:55kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding schemes available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZY18-10R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-10R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:105kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZY18-10R3 Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-10R3

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:130kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ18-15R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ18-15R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 18/55/105kV, rated frequency 50/60Hz; product weight:65kg; ambient operating temperature -5℃~+40℃, multiple accuracy grades optional.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX61-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX61-10-6G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 150VA / 300VA / 100VA
View Specs
JSZV2-15R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV2-15R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 18/55/105kV, rated frequency 50/60Hz; product weight:95kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZV18-15R Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV18-15R

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 18/55/105kV, rated frequency 50/60Hz; product weight:86kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZXF61-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF61-10-6G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 40VA / 50VA
View Specs
JDZX61-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX61-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden100VA / 200VA / 400VA / 100VA
View Specs
JDZX10-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6A

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 30VA / 50VA / 50VA
View Specs
JDZX10-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6BG

JDZX10-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 15VA / 100VA / 50VA
View Specs
JDZ9-10-6A Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-10-6A

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2,0.5,1.0 /0.2/0.5
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 40VA / 60VA
View Specs
JDZ9-10-6B Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ9-10-6B

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2,0.5,1.0 /0.2/0.5
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 60VA / 100VA
View Specs
JDZX9-10-10DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-10DG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer, compliant with GB/T20840.1, GB/T20840.3 and IEC61869-1, IEC61869-3 standards.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 75VA / 400VA / 150VA
View Specs