Single-phase multi-winding power transformer for 10kV/6kV systems. 4000/5000VA capacity, epoxy resin cast. Provides reliable control power for switchgear. Compliant with IEC 60076 and GB 1094. Low PD, moisture resistant. Customizable specifications.
Suitable for 10kV/6kV indoor switchgear control power applications requiring a dry-type, single-phase transformer with 4-5kVA capacity.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 60076, GB 1094 |
| Model Code | DC-4-5-10-6 | Factory nameplate marking |
| Primary Voltage | 10kV/6kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 60076, GB 1094 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Indoor single-phase epoxy cast multi-winding epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
For single-phase power transformers, follow IEC 60076 terminal markings. Primary terminals: A and B for 10kV or 6kV input. Secondary terminals: 1a and 1n for control output. Ground the secondary winding at one point. Never short-circuit the secondary while energized. Ensure proper fusing on primary side.
Compliant with: IEC 60076, GB 1094
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation class?
A: Dry epoxy resin insulation, suitable for indoor use.
Q: Can it be used outdoors?
A: No, it is designed for indoor installation only.
Q: What standards does it comply with?
A: IEC 60076 and GB 1094.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated voltage ratio (kV) | Accuracy classCombined | 220V winding rated output (VA) | 100V winding rated output (VA) | Weight (kg) |
|---|---|---|---|---|---|
| DC-4/10 DC-4/6 | 10/0.22 6/0.22 | — | 4000 | — | 80 |
| 10/0.1/0.22 6/0.1/0.22 | 0.2、0.5 | 4000 | 30、60 | 80 | |
| DC-5/10 DC-5/6 | 10/0.22 6/0.22 | — | 5000 | — | 90 |
| 10/0.1/0.22 6/0.1/0.22 | 0.2、0.5 | 5000 | 30、60 | 90 |

Dimension & outline drawing of DC-4-5-10-6 — click image to zoom / view original.
Same product family, different ratings — compare before you specify.
LXK Φ80 to Φ240 Zero Sequence Current Transformer for Earth Fault Protection
Indoor zero sequence current transformer for 35kV and below systems. Used for three-phase cable ground protection in small grounding current systems. Can also be used with relay protection devices. Rated frequency 50Hz or 60Hz. Available in Φ80 to Φ240 inner diameter sizes. Split design with clamp fastening, can be installed without power interruption. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, suitable for indoor installation.
35kV Indoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV A indoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.
LJZ-Φ75/110/125 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker
Zero sequence current transformer for 35kV and below voltage systems. Used for cable ground protection in small grounding current systems. Rated frequency 50Hz or 60Hz. Available in Φ75, Φ110, Φ125 inner diameter sizes. Primary insulation guaranteed by cable, secondary winding insulation tested. Compliant with IEC 61869 and GB/T 20840 standards. Matching relay model DL-11/0.2, epoxy resin cast construction.
Current Transformer for Inflatable Switchgear
Special current transformer designed for CGIS inflatable switchgear with multiple accuracy grades and abundant primary current specifications; secondary lead length and stacked product height support customized production.
35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV W1 outdoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.
Current Transformer Applied to CGIS Gas Insulated Switchgear
Indoor epoxy resin casting current transformer designed for CGIS gas insulated switchgear, with multiple accuracy class, rated burden and primary current options.