中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsVT / PT
Product category

Voltage Transformer (VT) / Potential Transformer (PT)

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

225 models

Representative Models

JDZX9-10-10CG Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX9-10-10CG

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX9-10-10CG is an indoor single-phase epoxy resin casting voltage transformer for 10kV systems, with a 0.1kV secondary. Accuracy combinations include 0.2/3P(6P), 0.5/3P(6P), 1.0/3P(6P) and 0.2/0.5/3P(6P), with rated burden 50VA / 50VA / 200VA / 100VA and insulation levels 12/42/75kV or 7.2/32/60kV. The dry-type epoxy casting body weighs 91kg and operates at 50Hz or 60Hz; design and testing follow GB/T20840.1, GB/T20840.3, IEC 61869-1 and IEC 61869-3.

Accuracy Class0.2/3P(6P),0.5/3P(6P),1.0/3P(6P),0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 50VA / 200VA / 100VA
View Specs
JDZ61-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ61-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ61-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 100VA / 200VA / 400VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden100VA / 200VA / 400VA
View Specs
JDZX6-10-6RG2M-G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX6-10-6RG2M-G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX6-10-6RG2M-G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P),1.0/3P(6P), rated burden 10VA / 20VA / 50VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/3P(6P),0.5/3P(6P),1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 20VA / 50VA / 50VA
View Specs
JDZU10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZU10-10-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZU10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5, rated burden 20VA / 40VA / 60VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 40VA / 60VA
View Specs
JDZX51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX51-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 60VA / 150VA / 300VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 150VA / 300VA / 100VA
View Specs
JDZ6-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ6-10-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ6-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 30VA / 50VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden30VA / 50VA / 100VA
View Specs
JDZX10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 20VA / 50VA / 100VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden20VA / 50VA / 100VA / 50VA
View Specs
JDZX10-10-6R2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX10-10-6R2

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX10-10-6R2 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 10VA / 15VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden10VA / 15VA / 50VA
View Specs
JDZ51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZ51-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZ51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2,0.5,1.0, rated burden 75VA / 150VA / 300VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2,0.5,1.0
Insulation TypeDry Epoxy Resin
Rated Burden75VA / 150VA / 300VA
View Specs
JDZXF19-10-6G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZXF19-10-6G1

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZXF19-10-6G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.2/3P(6P),0.2/0.5/3P(6P), rated burden 50VA / 50VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/0.2/3P(6P),0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden50VA / 50VA / 100VA
View Specs
JDZX61-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX61-10-6G

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX61-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 60VA / 150VA / 300VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA / 150VA / 300VA / 100VA
View Specs
JDZX61-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50Hz or 60Hz

JDZX61-10-6

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

JDZX61-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P), rated burden 100VA / 200VA / 400VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.

Accuracy Class0.2/6P(3P),0.5/6P(3P),1.0/6P(3P)
Insulation TypeDry Epoxy Resin
Rated Burden100VA / 200VA / 400VA / 100VA
View Specs