Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
225 models
Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz, weight 28kg, aluminum hull sealed structure.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:105kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZY18-10FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZY18-10FR-2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Outdoor Three-phase Silicone Rubber Voltage Transformer 6kV with Fuse
Outdoor three-phase silicone rubber composite insulation voltage transformer, 6kV rated, with primary fuse, for voltage measurement and protection in three-phase power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/0.1kV, rated frequency 50/60Hz; accuracy class rated output:30VA(0.2),60VA(0.5),100VA(1.0); limiting thermal output of secondary winding 600VA; product weight:31kg; ambient operating temperature -5℃~+40℃.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV19-10R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
JDZX15-10R(CQ) Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer (JDZX15-10R-CQ) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
Indoor three-phase metal armouReddish Brown epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:55kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding schemes available.
Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
JDZX15-10R2-CQ Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ18-20R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2 / 0.5. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/0.1/0.22kV, rated frequency 50/60Hz; accuracy class rated output:20VA(0.2),40VA(0.5),60VA(1.0); maximum power output 500VA; product weight:31kg; ambient operating temperature -5℃~+40℃.