Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
Outdoor Single-phase Silicone Rubber Voltage Transformer 10kV 6kV with 2 Fuses
Outdoor single-phase silicone rubber composite insulation voltage transformer with 2 primary fuses, 10kV/6kV rated, for voltage measurement and protection in distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 1.0. Customizable ratios and specs.
Current Transformer
Indoor epoxy resin casting current transformer complying with GB/T20840.1, GB/T20840.2, IEC61869-1 and IEC61869-2 standards, rich primary current specifications and multi-type accuracy grades optional for different application scenarios.
Indoor Single-phase Epoxy Resin Casting Current Transformer for Solid Insulation Ring Cabinet
Indoor single-phase epoxy resin casting current transformer dedicated for solid insulation ring main unit, complying with GB/T20840.1, GB/T20840.2, IEC61869-1 and IEC61869-2 standards.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated voltage ratio 10/0.1kV, rated frequency 50/60Hz; accuracy class rated output:30VA(0.2),60VA(0.5),100VA(1.0); limiting thermal output of secondary winding 600VA; product weight:31kg; ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated voltage ratio 10/0.1/0.22kV, rated frequency 50/60Hz; accuracy class rated output:20VA(0.2),40VA(0.5),60VA(1.0); maximum power output 500VA; product weight:31kg; ambient operating temperature -5℃~+40℃.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated voltage ratio 10/0.1kV, rated frequency 50/60Hz; accuracy class rated output:60VA(0.2),150VA(0.5),200VA(1.0); limiting thermal output of secondary winding 800VA; product weight:43kg; ambient operating temperature -5℃~+40℃.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Outdoor pole-mounted single-phase power transformer, 10kV/6kV. 8000VA capacity, epoxy resin cast construction. Provides control power supply for pole-mounted switchgear. Compliant with IEC 60076 standards. Weather-resistant design, reliable outdoor performance.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Single-phase epoxy resin cast power transformer for 10kV/6kV switchgear. Multi-winding design, 2000/3000VA capacity. Provides control and operation power supply. Compliant with IEC 60076 standards. Low partial discharge, long service life. Customizable voltage ratio.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Single-phase epoxy resin cast power transformer for 10kV/6kV pole-mounted switchgear. Provides reliable control power supply for circuit breakers. Compliant with IEC 60076 and GB 1094 standards. Low partial discharge, excellent moisture resistance. Customizable voltage ratio and capacity.
10kV/6kV Single-Phase Power Transformer for Pole-Mounted Switchgear
Single-phase multi-winding power transformer for 10kV/6kV systems. 4000/5000VA capacity, epoxy resin cast. Provides reliable control power for switchgear. Compliant with IEC 60076 and GB 1094. Low PD, moisture resistant. Customizable specifications.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz; product weight:95kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz; product weight:65kg; ambient operating temperature -5℃~+40℃, multiple accuracy grades optional.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:125kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:105kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.
Indoor Three-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
Indoor three-phase metal armouReddish Brown epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:55kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding schemes available.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:77kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding types available.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase multi-winding epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:98kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.
Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz, weight 28kg, aluminum hull sealed structure.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin insulated voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:72kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding types available.
Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armouReddish Brown epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:85kg, aluminum shell structure with built-in fuse.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armoured epoxy casting VT with built-in fuse, compliant with GB/T20840.1/3 & IEC61869-1/3; insulation level 24/65/125kV, 50/60Hz, matched fuse XRNP□-24 type 0.5A 50kA, weight 85kg.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/0.1/0.22kV, rated frequency 50/60Hz; accuracy class rated output:40VA(0.2),100VA(0.5),150VA(1.0); maximum power output 1000VA; product weight:43kg; ambient operating temperature -5℃~+40℃.
Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
Indoor single-phase metal armouReddish Brown epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:48kg, aluminum shell structure with built-in fuse.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
Indoor three-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 12/42/75kV, rated frequency 50/60Hz; product weight:125kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades available.