中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZ8-10
LMZ8-10 Current Transformer
10 kVLMZ8-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10 kV
Secondary Metering (1S1 - 1S2):5A or 1A (0.2S, 0.5, 10P20, 10P10)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZ8-10

LMZ8-10 Current Transformer

Indoor epoxy resin casting current transformer complying with GB/T20840.1, GB/T20840.2, IEC61869-1 and IEC61869-2 standards, rich primary current specifications and multi-type accuracy grades optional for different application scenarios.

Key Engineering Advantages

  • Integrated casting structure
  • measurement/protection/double-winding accuracy classes available
  • stable insulating performance
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZ8-10

Electrical Parameters

Primary Rated Voltage (Un):10 kV
Secondary Winding Currents:5A or 1A
Metering & Protection Class:0.2S, 0.5, 10P20, 10P10
Rated Frequency:50Hz or 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75kV
Standards Conformance:GB/T20840.1, GB/T20840.2, IEC61869-1, IEC61869-2
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy resin CT for 12kV systems; suitable for measurement and protection in RMU applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerGB/T20840.1, GB/T20840.2, IEC61869-1, IEC61869-2
Model CodeLMZ8-10Factory nameplate marking
Primary Voltage10 kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class0.2S, 0.5, 10P20, 10P10Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75kVPower-frequency & lightning impulse withstand
StandardsGB/T20840.1, GB/T20840.2, IEC61869-1, IEC61869-2Certified to listed standards
Frequency50Hz or 60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor ring main unit (RMU) applications
  • 12kV primary systems
  • Revenue metering and protection schemes
  • Dry, non-polluted environments

Not Recommended For

  • Outdoor substations
  • Gas-insulated switchgear (GIS)
  • High-altitude installations above 1000m
  • Systems above 12kV

Topology & Wiring

connect secondary terminals 1S1/1S2 for measurement, and 2S1/2S2 for protection if dual-winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: GB/T20840.1, GB/T20840.2, IEC61869-1, IEC61869-2

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: The primary voltage is 12/42/75 kV, indicating a 12kV system with 42kV power-frequency and 75kV lightning impulse withstand.

Q: What secondary ratings are available?

A: Secondary current is 5A or 1A, as specified.

Q: What standards does it comply with?

A: It complies with GB/T20840.1, GB/T20840.2, IEC61869-1, and IEC61869-2.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZ8-10
9 cols · 16 rows

LMZ8-10 Current Transformer — Technical Data

Rated primary current I1n (A)Measuring class Current Transformer 0.2SMeasuring class Current Transformer 0.5Protection Current Transformer 10P20Protection Current Transformer 10P10Dual-winding Current Transformer 0.2SDual-winding Current Transformer 0.5Dual-winding Current Transformer 10P10Weight (kg)
50/1—1.5—1.5———6
75/1—2.5—2.5———6
100/11.53.751.53.75—1.51.56
150/12.552.55—2.51.56
200/13.757.53.757.52.53.752.56
300/15105103.7553.756
400/17.5157.51557.556
500/1102010207.5107.56
50/5———1.5———6
75/5—2.5—2.5———6
100/5—3.751.53.75——1.56
150/52.552.55—2.51.56
200/53.757.53.757.52.53.752.56
300/55105103.7553.756
400/57.5157.51557.556
500/5102010207.5107.56
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZ8-10 — click image to zoom / view original.

Product Overview

About This Product

LMZ8-10

The LMZ8-10 is a 10 kV indoor current transformer built on a dry epoxy resin insulation system, a construction that removes the liquid-handling and maintenance routines associated with oil-immersed units while keeping the secondary circuit isolated from the primary. The winding assembly is encapsulated in an integrated casting structure, and the vacuum or APG casting route is what gives the solid insulation its void-free character.

Accuracy classes span 0.2S, 0.5, 10P20 and 10P10, with rated outputs from 1.5VA to 10VA depending on the ratio; the 0.2S class holds its error band from light load through full load, which matters where tariff metering is involved. Insulation level is 12/42/75kV to GB/T20840.1, GB/T20840.2, IEC61869-1 and IEC61869-2, and calibration certificates for metering service can be supplied. Typical deployment is inside medium-voltage switchgear, ring-main units and centre-mounted cubicles.

This unit is for indoor service only and must not be installed in open-air locations. Before energising, verify the secondary burden in VA against the nameplate, earth the secondary at one point, and never open-circuit the secondary while the primary is live. Ratio and class options, documentation packages and lead times are confirmed at enquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs