中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • AI Is Hungry for Power: How Many Instrument Transformers Does an AI Data Center Need?
  • From 110 kV to the GPU: CTs and PTs Across an AI Data Center Power Chain
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCombined Instrument TransformerJLDZ6-10W
JLDZ6-10W Outdoor Single-phase Epoxy Resin Casting Combined Transformer 10kV
10kVJLDZ6-10W
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding:10kV
Secondary Winding: ()
Safety:Follow nameplate terminal diagram; ground secondary at one point
Combined Instrument Transformer IEC 61869-3 Certified
Model Ref:JLDZ6-10W

JLDZ6-10W Outdoor Single-phase Epoxy Resin Casting Combined Transformer 10kV

Outdoor single-phase epoxy resin casting combined transformer current + voltage integrated, 10kV rated, for metering and protection in single-phase power distribution systems. Complies with GB/T 17201 standard. Epoxy resin construction, good weather resistance, anti-UV, pollution class IV, suitable for outdoor installation. Integrated CT and VT design, compact structure. Customizable ratios and accuracy classes.

Key Engineering Advantages

  • Outdoor single-phase combined transformer CT+VT
  • 10kV
  • epoxy resin
  • pollution class IV
  • compact design
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: JLDZ6-10W

Electrical Parameters

Primary Rated Voltage (Un):10kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:GB/T 17201
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Outdoor combined CT+VT for 10kV single-phase systems; suitable for metering and protection in outdoor distribution.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCombined Instrument TransformerGB/T 17201
Model CodeJLDZ6-10WFactory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Windings[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsGB/T 17201Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Outdoor 10kV single-phase power distribution systems
  • Metering and protection applications
  • Areas with high pollution (class IV)
  • Compact installations requiring combined CT+VT

Not Recommended For

  • Indoor installations (designed for outdoor use)
  • Three-phase systems without additional units
  • Voltage levels above 10kV
  • High-frequency or DC applications

Topology & Wiring

For combined transformer: ground the secondary winding at one point. For CT: never open-circuit the secondary while energized - hazardous voltage. For VT: never short-circuit the secondary while energized - dangerous overcurrent. CT secondary terminals: 1S1/1S2 (protection winding 2S1-2S2). VT secondary terminals: 1a/1n. Follow IEC 61869 / IEEE C57.13 conventions.

Standards & Compliance

Compliant with: GB/T 17201

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of this transformer?

A: The primary voltage is 10kV; insulation level details are [On Request].

Q: Can it be used indoors?

A: No, it is designed for outdoor installation with weather-resistant epoxy resin.

Q: What standards does it comply with?

A: It complies with GB/T 17201.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

JLDZ6-10W
7 cols · 4 rows

JLSZV6-10W Combined Instrument Transformer — Technical Data

Rated current ratio (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8 (0.2 (S))Accuracy class & rated output (VA) COSΦ=0.8 (0.5)Rated Short-time thermal current (kA)Rated dynamic current (kA)Weight (kg)
5/5-75/50.2(S) 0.510 or 1510 or 15100I1n250I1n75
100/5-200/50.2(S) 0.510 or 1510 or 15150I1n375I1n75
300/50.2(S) 0.510 or 1510 or 1531.58075
400/5-600/50.2(S) 0.510 or 1510 or 156313075
Engineering Drawing

Specification & Outline Drawing

JLDZ6-10W specification drawing

Dimension & outline drawing of JLDZ6-10W — click image to zoom / view original.

Product Overview

About This Product

JLDZ6-10W

This is a 10 kV outdoor single-phase combined instrument transformer that integrates current and voltage functions in one epoxy-resin-cast unit, feeding metering and protection circuits in distribution switchgear and substations. Its dry epoxy resin insulation and cast construction suit outdoor service, with a pollution class IV creepage profile for exposed locations.

The unit delivers accuracy classes 0.2 and 0.5 with a rated burden of 0.2 VA at 50/60 Hz, so secondary cabling and meter loads must be matched to that window. It follows GB/T 17201, and type and routine test reports are available [On Request]. Typical deployment is on outdoor distribution lines, pole-mounted or in box substations.

Earth the secondary at one point and bond the case; never open-circuit the current secondary or short-circuit the voltage secondary while energized. Verify polarity and ratio before energization. Custom ratios, accuracy classes and documentation packages are quoted on request, with lead time confirmed at inquiry. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.

Other Models in This Series

Same product family, different ratings — compare before you specify.

JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
10kV
Combined Instrument Transformer50/60Hz

JLSZV6-10W

Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV

JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to GB/T 17201.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 17201
View Specs
JLSZV8-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
10kV
Combined Instrument Transformer50/60Hz

JLSZV8-10W

Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV

JLSZV8-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to GB/T 17201.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 17201
View Specs