中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • AI Is Hungry for Power: How Many Instrument Transformers Does an AI Data Center Need?
  • From 110 kV to the GPU: CTs and PTs Across an AI Data Center Power Chain
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCombined Instrument TransformerJLSZV6-10W
JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
10kVJLSZV6-10W
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding:10kV
Secondary Winding: ()
Safety:Follow nameplate terminal diagram; ground secondary at one point
Combined Instrument Transformer IEC 61869-3 Certified
Model Ref:JLSZV6-10W

JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV

JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to GB/T 17201.

Key Engineering Advantages

  • Outdoor three-phase combined transformer CT+VT
  • 10kV
  • epoxy resin
  • pollution class IV
  • compact design
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: JLSZV6-10W

Electrical Parameters

Primary Rated Voltage (Un):10kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:GB/T 17201
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Outdoor combined transformer for 10kV three-phase metering and protection; epoxy resin insulation, pollution class IV.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCombined Instrument TransformerGB/T 17201
Model CodeJLSZV6-10WFactory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Windings[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsGB/T 17201Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 10kV outdoor distribution networks
  • Three-phase metering and protection applications
  • Areas with high pollution (class IV)
  • Compact installations requiring combined CT+VT

Not Recommended For

  • Indoor installations (designed for outdoor)
  • Voltages above 10kV
  • High-frequency or DC applications
  • Oil-immersed transformer requirements

Topology & Wiring

For combined transformer: ground the secondary winding at one point. For CT: never open-circuit the secondary while energized - hazardous voltage. For VT: never short-circuit the secondary while energized - dangerous overcurrent. Terminal naming: CT secondary 1S1/1S2 (protection winding 2S1-2S2), VT secondary 1a/1n. Follow IEC 61869 / IEEE C57.13 conventions.

Standards & Compliance

Compliant with: GB/T 17201

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation type and pollution class?

A: Dry epoxy resin, pollution class IV.

Q: What is the primary voltage rating?

A: 10kV.

Q: Is it suitable for outdoor installation?

A: Yes, designed for outdoor use with anti-UV properties.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

JLSZV6-10W
7 cols · 4 rows

JLSZV6-10W Combined Instrument Transformer — Technical Data

Rated current ratio (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8 0.2 (S)Accuracy class & rated output (VA) COSΦ=0.8 0.5Rated Short-time thermal current (kA)Rated dynamic current (kA)Weight (kg)
5/5-75/50.2(S) 0.510 or 1510 or 15100I1n250I1n75
100/5-200/50.2(S) 0.510 or 1510 or 15150I1n375I1n75
300/50.2(S) 0.510 or 1510 or 1531.58075
400/5-600/50.2(S) 0.510 or 1510 or 156313075
Engineering Drawing

Specification & Outline Drawing

JLSZV6-10W specification drawing

Dimension & outline drawing of JLSZV6-10W — click image to zoom / view original.

Product Overview

About This Product

JLSZV6-10W

The JLSZV6-10W is a 10kV outdoor three-phase combined instrument transformer that integrates current and voltage measurement functions in one epoxy resin cast body, and its design and testing follow GB/T 17201. Because it occupies a single compact footprint instead of separate CT and VT units, it helps free panel and switchyard space in distribution layouts where room is tight.

The unit is available with current ratios from 5/5-75/5 up to 400/5-600/5, accuracy classes 0.2(S) and 0.5, and rated outputs of 10 or 15 VA at COSΦ=0.8; short-time thermal and dynamic ratings scale with the selected ratio, and each unit weighs 75 kg. It is intended for outdoor pole-mounted or box-substation service on 10kV distribution lines, with pollution class IV suited to exposed locations. Before energizing, verify insulation resistance, polarity and ratio, earth the secondary at one point, and never short-circuit the voltage secondary while energized.

Ratios and accuracy classes can be customized, and export packing with after-sales support is available; consult the nameplate and official datasheet for [On Request] details. ⚠️ Safety: Follow the nameplate terminal diagram and ground the secondary winding at one point.

Other Models in This Series

Same product family, different ratings — compare before you specify.

JLSZV8-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
10kV
Combined Instrument Transformer50/60Hz

JLSZV8-10W

Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV

JLSZV8-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to GB/T 17201.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 17201
View Specs
JLDZ6-10W Outdoor Single-phase Epoxy Resin Casting Combined Transformer 10kV
10kV
Combined Instrument Transformer50/60Hz

JLDZ6-10W

Outdoor Single-phase Epoxy Resin Casting Combined Transformer 10kV

Outdoor single-phase epoxy resin casting combined transformer current + voltage integrated, 10kV rated, for metering and protection in single-phase power distribution systems. Complies with GB/T 17201 standard. Epoxy resin construction, good weather resistance, anti-UV, pollution class IV, suitable for outdoor installation. Integrated CT and VT design, compact structure. Customizable ratios and accuracy classes.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 17201
View Specs