KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLDZC-10PU
LDZC-10PU Indoor Cable-Fixed Self-Powered Current Transformer
10kVLDZC-10PU
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 10kV
Secondary Metering (1S1 - 1S2): (0.2/0.5/3P(6P))
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LDZC-10PU

LDZC-10PU Indoor Cable-Fixed Self-Powered Current Transformer

LDZC-10PU Indoor Cable-Fixed Self-Powered Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA(0.2),40VA(0.5),100VA(3P). Design: Dry Epoxy Resin, 50Hz/60Hz operation.

Key Engineering Advantages

  • Cable-fixed self-powered CT with independent power winding for passive microcomputer protection systems
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LDZC-10PU

Electrical Parameters

Primary Rated Voltage (Un):10kV
Metering & Protection Class:0.2/0.5/3P(6P)
Rated Output Burden:30VA(0.2),40VA(0.5),100VA(3P)
Rated Frequency:50Hz/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor self-powered CT for cable-fixed installations, suited for passive protection systems in RMU applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLDZC-10PUFactory nameplate marking
Primary Voltage10kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class0.2/0.5/3P(6P)Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden30VA(0.2),40VA(0.5),100VA(3P)Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor ring main unit (RMU) applications
  • Cable-fixed through-type installations
  • Passive microcomputer integrated protection devices
  • Systems requiring self-powering from primary current
  • 50Hz/60Hz networks

Not Recommended For

  • Outdoor substation installations
  • High-voltage transmission lines above 20kV
  • Applications requiring metering accuracy above 0.2 class
  • Non-cable-fixed busbar or transformer bushings
  • Environments requiring oil or gas insulation

Topology & Wiring

For current transformers, never open-circuit the secondary while energized—hazardous voltage may occur. Standard terminal markings: 1S1/1S2 for main secondary, 2S1/2S2 for protection winding. Ground the secondary winding at one point. Ensure power winding connections are correct for self-powering functionality.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: The primary voltage is 20kV.

Q: What accuracy classes are available?

A: Accuracy classes are 0.2/0.5/3P(6P) with rated burdens 30VA, 40VA, and 100VA respectively.

Q: How does the self-powered feature work?

A: The built-in power winding generates energy from primary current when it exceeds 10% of rated primary current, with power factor COSφ=0.8.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LDZC-10PU
5 cols · 7 rows

LDZC-10PU Self-powered Current Transformer — Technical Data

ModelRated primary current I1n (A)Accuracy class & rated output (VA) COSΦ=0.8 Protection winding10P10Accuracy class & rated output (VA) COSΦ=0.8 Power supply windingDimensions Φd/ΦD/H
LDZC1240-10PU50/51.5540/125/130
LDZC1240-10PU75/52.5540/125/130
LDZC1240-10PU100/53.75540/125/130
LDZC1365-10PU200/53.75565/130/110
LDZC1365-10PU300/55565/130/110
LDZC1150-10PU400/55550/110/100
LDZC1150-10PU600/57.5550/110/100
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LDZC-10PU — click image to zoom / view original.

Product Overview

About This Product

LDZC-10PU

The LDZC-10PU is an indoor cable-fixed self-powered current transformer for 10kV switchgear bays, such as KYN28 cubicles and ring-main units, where it supplies both measurement and a passive microcomputer protection system. Its dry epoxy resin insulation and independent power winding are built around cable-fixed primary routing.

Electrical performance covers accuracy classes 0.2/0.5/3P(6P) with rated burdens of 30VA(0.2), 40VA(0.5) and 100VA(3P) at 50Hz/60Hz. Factory routine tests, ratio and polarity checks gate each unit; protection-core saturation behaviour under fault current is stated on the nameplate and datasheet. In the single-winding versus multi-winding choice, this unit suits combined metering and protection with a self-powered supply.

Compliance follows the IEC 61869 series, with test certificates and routine reports available [On Request]. Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Mounting space, safety clearances and cable fixing must be confirmed against the outline drawing, and the secondary must never be open-circuited while energized. DC or non-standard frequencies are not applicable. OEM branding, ratio and class customization, and document packages are quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LDZC-10 Indoor Cable-Fixed High-Precision Current Transformer
10kV
Current Transformer50Hz/60Hz

LDZC-10

Indoor Cable-Fixed High-Precision Current Transformer

LDZC-10 Indoor Cable-Fixed High-Precision Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P), rated burden 60VA(0.2),120VA(0.5),200VA(1.0),100VA(3P). Design: Dry Epoxy Resin, 50Hz/60Hz operation.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)、1.0/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden60VA(0.2),120VA(0.5),200VA(1.0),100VA(3P)
View Specs
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1765

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs