CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin cast CT for CGIS, 35kV, 50/60Hz. Suitable for metering and protection in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS1765 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: 35kV.
Q: What is the insulation type?
A: Dry epoxy resin.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor CGIS applications.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2FS10 | 2.5 | — | — | — | — | — | 65 | 55 | 40 | 35 | 30 | 30 | 30 | 30 | 35 | 35 | 35 |
| 0.2FS10 | 5 | — | — | — | — | — | 95 | 80 | 55 | 50 | 35 | 30 | 30 | 30 | 35 | 35 | 35 |
| 0.2FS10 | 10 | — | — | — | — | — | 120 | 80 | 60 | 45 | 35 | 35 | 30 | 30 | 35 | 35 | 35 |
| 0.2FS10 | 15 | — | — | — | — | — | 170 | 110 | 75 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | 35 |
| 0.2FS10 | 20 | — | — | — | — | — | 145 | 90 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 | 35 |
| 0.2FS10 | 25 | — | — | — | — | — | 160 | 110 | 75 | 60 | 50 | 45 | 45 | 40 | 35 | 35 | 35 |
| 0.2FS10 | 30 | — | — | — | — | — | — | 125 | 85 | 70 | 55 | 55 | 50 | 45 | 40 | 40 | 40 |
| 0.5 | 2.5 | — | — | — | 55 | 45 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 | 5 | — | — | — | 80 | 65 | 50 | 40 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 | 10 | — | — | — | 125 | 95 | 75 | 55 | 40 | 35 | 35 | 30 | 25 | 25 | 25 | 25 | — |
| 0.5 | 15 | — | — | — | 125 | 95 | 70 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | — |
| 0.5 | 20 | — | — | — | 120 | 85 | 65 | 55 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | — |
| 0.5 | 25 | — | — | — | — | 95 | 75 | 65 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | — |
| 0.5 | 30 | — | — | — | — | — | 85 | 70 | 65 | 55 | 50 | 45 | 40 | 35 | 30 | 30 | 30 |
| 5(10)P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 25 | 25 | 25 |
| 5(10)P10 | 5 | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 40 | 35 | 35 | 30 | 30 | 30 | 30 |
| 5(10)P10 | 10 | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 50 | 45 | 45 | 35 | 35 | 35 | 35 | — |
| 5(10)P10 | 15 | — | — | — | 155 | 130 | 110 | 90 | 80 | 80 | 65 | 60 | 50 | 45 | 40 | 40 | — |
| 5(10)P10 | 20 | — | — | — | — | 140 | 115 | 100 | 95 | 80 | 70 | 60 | 50 | 45 | 45 | 45 | — |
| 5(10)P10 | 25 | — | — | — | — | — | 140 | 120 | 115 | 95 | 80 | 70 | 60 | 55 | 55 | 55 | — |
| 5(10)P10 | 30 | — | — | — | — | — | — | 140 | 130 | 110 | 95 | 80 | 65 | 60 | 60 | 60 | — |
| 5(10)P20 | 2.5 | — | — | 145 | 125 | 90 | 75 | 65 | 60 | 50 | 50 | 45 | 40 | 40 | 35 | 35 | — |
| 5(10)P20 | 5 | — | — | 145 | 115 | 95 | 90 | 75 | 70 | 65 | 55 | 50 | 50 | 45 | 40 | 40 | — |
| 5(10)P20 | 10 | — | — | — | — | 150 | 125 | 110 | 105 | 85 | 75 | 70 | 60 | 55 | 55 | 55 | — |
| 5(10)P20 | 15 | — | — | — | — | — | 150 | 140 | 115 | 100 | 90 | 75 | 70 | 70 | 70 | 70 | — |
| 5(10)P20 | 20 | — | — | — | — | — | — | 145 | 125 | 115 | 90 | 80 | 80 | 80 | 80 | 80 | — |
| 5(10)P20 | 25 | — | — | — | — | — | — | — | 150 | 135 | 105 | 95 | 95 | 95 | 95 | 95 | — |
| 5(10)P20 | 30 | — | — | — | — | — | — | — | — | 155 | 120 | 105 | 105 | 105 | 105 | 105 | — |
| 5(10)P30 | 2.5 | — | — | — | 130 | 105 | 90 | 85 | 75 | 70 | 65 | 55 | 55 | 55 | 50 | 50 | — |
| 5(10)P30 | 5 | — | — | — | — | 145 | 135 | 115 | 100 | 95 | 80 | 75 | 75 | 65 | 60 | 60 | — |
| 5(10)P30 | 10 | — | — | — | — | — | 170 | 155 | 125 | 115 | 110 | 90 | 80 | 80 | 80 | 80 | — |
| 5(10)P30 | 15 | — | — | — | — | — | — | 155 | 140 | 115 | 100 | 100 | 100 | 100 | 100 | — | — |
| 5(10)P30 | 20 | — | — | — | — | — | — | — | 140 | 125 | 125 | 125 | 125 | 125 | — | — | — |
| 5(10)P30 | 25 | — | — | — | — | — | — | — | — | — | 145 | 145 | 145 | 145 | — | — | — |
Dimension & outline drawing of CGIS1765 — click image to zoom / view original.
This current transformer is a 35 kV indoor unit for CGIS gas insulated switchgear, built to the IEC 61869 series and the corresponding GB/T 20840 requirements for instrument transformers. It measures and protects the primary circuit at 50/60 Hz, with accuracy classes covering 0.2FS10, 0.5SFS10, 0.5, 5(10)P10 and 5(10)P15.
The dry epoxy resin casting and square housing with a Φ65 mm inner window keep the unit compact, so it occupies little space in the switchgear compartment and simplifies panel layout. Protection cores are available in 5(10)P10 and 5(10)P15, and the 0.2FS10 and 0.5SFS10 metering classes hold accuracy down to a small fraction of rated current. Rated outputs in VA are read from the parameter table for the chosen class and ratio; the nameplate and official datasheet carry the final values.
This indoor CT is intended for medium-voltage switchgear, ring main units and withdrawable cubicles. Earth the secondary at one point and never open-circuit it while energized. It is not for outdoor exposure. Ratio, class and secondary winding configuration can be customized, with test reports and documentation supplied on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.