Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards, insulation level 12/42/75kV, rated frequency 50/60Hz, secondary rated current 5A or 1A. Optional primary current:2500A、3000A、4000A、5000A; accuracy combinations include 0.2/5P20、0.5/5P10/5P20、0.2/5P10/5P20、0.2/5P20/5P20, corresponding rated output specifications such as 30/30VA,30/25/25VA etc., net weight 30kg, ambient operating temperature -5℃~+40℃.
Indoor 10kV cast-resin current transformer for MV switchgear, metering and protection.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LMZB1-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Ambient: -5℃~+40℃ | Per datasheet limits |
Ideal For
Not Recommended For
connect secondary terminals 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: 12kV system; power-frequency withstand 42kV; lightning impulse withstand 75kV peak.
Q: What secondary currents are available?
A: 5A or 1A as per specification.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSΦ=0.8 | Weight (kg) |
|---|---|---|---|
| 2500 | 0.2/5P20 0.5/5P10/5P20 0.2/5P10/5P20 0.2/5P20/5P20 | 30/30 30/30/30 30/30/30 30/20/20 | 30 |
| 3000 | 0.2/5P20 0.5/5P10/5P20 0.2/5P10/5P20 0.2/5P20/5P20 | 30/30 30/30/30 30/30/30 30/20/20 | 30 |
| 4000 | 0.2/5P20 0.5/5P10/5P20 0.2/5P10/5P20 0.2/5P20/5P20 | 30/30 30/30/30 30/30/30 30/20/20 | 30 |
| 5000 | 0.2/5P20 0.5/5P10/5P20 0.2/5P10/5P20 0.2/5P20/5P20 | 30/30 30/30/30 30/30/30 30/20/20 | 30 |
The LMZB1-10 is a 10kV indoor single-phase epoxy resin cast current transformer, typically installed in switchgear bays and ring-main units to step primary current down to 5A/1A for metering and protection. Its dry epoxy body is vacuum cast to form a gapless solid insulation around the winding, with an equipotential line design controlling the internal field.
The insulation level is 12/42/75kV for 50/60Hz service, so power-frequency withstand and lightning impulse capability suit 10kV distribution. Accuracy combinations include 0.2/5P20, 0.5/5P10/5P20 and 0.2/5P10/5P20, with rated outputs of 30/30, 30/30/30 or 30/20/20VA at cosΦ=0.8; single metering, metering plus protection, or multi-winding versions are all available. Compliance follows the IEC 61869 series, with type-test and sample support offered.
Deployment covers indoor renewable-energy collection and step-up substations within -5℃~+40℃. Earth the secondary at one point and never open-circuit it while energized. The 10kV class is a hard ceiling, so do not apply it at higher system voltages. Ratio and accuracy customization, documentation packages and delivery terms are [On Request]; weight is 30kg.
Same product family, different ratings — compare before you specify.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Optional primary current covers 2500-5000A; multiple accuracy class combinations available with rated output ranging 20-30VA; product weight:60kg; ambient operating temperature -5℃~+40℃.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.