KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZBJ4-35A
LZZBJ4-35A 35kV Indoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kVLZZBJ4-35A
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A or 1A (0.2S, 0.5S, 10P10, 10P25)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZBJ4-35A

LZZBJ4-35A 35kV Indoor Epoxy Cast Post-Type Current Transformer with Protection Winding

35kV A indoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.

Key Engineering Advantages

  • 35kV A CT
  • 40.5kV insulation
  • multi-accuracy windings
  • IEC 61869 compliant
  • high short-time current withstand
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZBJ4-35A

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A or 1A
Metering & Protection Class:0.2S, 0.5S, 10P10, 10P25
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Environmental Class:A indoor pillar type epoxy resin cast
Standards Conformance:IEC 61869, GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

35kV power distribution system
GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LZZBJ4-35A is a 35kV indoor epoxy cast current transformer with protection winding, suitable for metering and protection in 35kV distribution systems.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869, GB/T 20840
Model CodeLZZBJ4-35AFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class0.2S, 0.5S, 10P10, 10P25Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
StandardsIEC 61869, GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentA indoor pillar type epoxy resin castPer datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 35kV indoor switchgear and panels
  • Revenue metering with 0.2S/0.5S accuracy
  • Protection applications with 10P10/10P25 windings
  • Systems requiring high short-time thermal current (50kA/4s)

Not Recommended For

  • Outdoor installations (indoor type only)
  • Gas-insulated switchgear (GIS) applications
  • DC systems or non-50/60Hz applications
  • Voltage transformation (CT only)

Topology & Wiring

Connect primary through bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point. Follow IEC 61869 terminal markings.

Standards & Compliance

Compliant with: IEC 61869, GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the insulation level of LZZBJ4-35A?

A: Rated insulation level is 40.5kV system, power-frequency withstand 95kV, lightning impulse withstand 185kV peak.

Q: What accuracy classes are available?

A: Metering: 0.2S or 0.5S; Protection: 10P10 or 10P25.

Q: Can it be used outdoors?

A: No, it is designed for indoor use only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZBJ4-35A
9 cols · 5 rows

LZZBJ4-35W1, LZZBJ4-35W2, LZZBJ4-35A Series Current Transformer — Technical Data

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) 0.2/0.5Accuracy class & rated output (VA) 0.5Accuracy class & rated output (VA) 10P10Accuracy class & rated output (VA) 10P20Short-time thermal current Ith (kA/s)Rated dynamic current Idyn (kA)Weight (kg)
50-1000.2/5(0.5/5)10P10P 0.2/5(0.5/5)10P10P1020251550 1n/4125 1n75
150-2000.2/5(0.5/5)10P10P 0.2/5(0.5/5)10P10P1020251520/24075
300-5000.2/5(0.5/5)10P10P 0.2/5(0.5/5)10P10P1020251531.5/48075
600-8000.2/5(0.5/5)10P10P 0.2/5(0.5/5)10P10P1020251540/410075
1000-15000.2/5(0.5/5)10P10P 0.2/5(0.5/5)10P10P1020251550/410075
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZBJ4-35A — click image to zoom / view original.

Product Overview

About This Product

LZZBJ4-35A

The LZZBJ4-35A is a 35kV indoor post-type current transformer designed for metering and protection in 35kV power distribution systems, and it is built to the IEC 61869 and GB/T 20840 standards. Its dry epoxy resin cast insulation provides a 40.5/95/185kV insulation level, and the pillar-type body houses metering and protection windings in one unit.

Accuracy classes include 0.2S, 0.5S, 10P10 and 10P25, with a rated burden of 10VA and a 5A or 1A secondary. The parameter table lists short-time thermal current from 20/2 kA/s to 50/4 kA/s and dynamic current from 40 kA to 125 kA, depending on the primary current range, with a weight of 75 kg. Compared with oil-immersed or SF6 designs, the dry cast construction avoids liquid or gas handling, but it is strictly for indoor service.

Typical deployment includes 35kV distribution boards and renewable-energy collector or storage step-up stations. Before energizing, verify the secondary burden against the rated 10VA and earth the secondary at one point. Never open-circuit the secondary while energized. Custom ratios, accuracy combinations and documentation packages are available [On Request], and export packing and after-sales support are offered.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZBJ4-35W1 35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV
Current Transformer50/60Hz

LZZBJ4-35W1

35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding

35kV W1 outdoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.

Accuracy Class0.2S, 0.5S, 10P10, 10P25
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
LZZBJ4-35W2 35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV
Current Transformer50/60Hz

LZZBJ4-35W2

35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding

35kV W2 outdoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.

Accuracy Class0.2S, 0.5S, 10P10, 10P25
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs