CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.
Indoor CT for 35kV CGIS; dry epoxy insulation; multiple accuracy and burden options.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2070-I | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
connect secondary terminals 1S1/1S2 for main winding; if present, protection winding 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point per IEC 61869-2.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: 35kV.
Q: What are the dimensions?
A: Outer diameter Ø205mm, inner diameter Ø70mm.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor CGIS applications.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy classCombined | Rated output (VA) | Rated primary current (A) - | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 | ||
| 0.2FS10 / 0.5FS10 | 2.5 | — | — | — | — | 45 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 5 | — | — | — | — | 70 | 40 | 40 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 10 | — | — | — | — | — | 60 | 50 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 15 | — | — | — | — | — | — | 50 | 40 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 20 | — | — | — | — | — | — | — | — | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 25 | — | — | — | — | — | — | — | — | — | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 30 | — | — | — | — | — | — | — | — | — | — | 40 | 35 | 30 | 30 | 30 | 30 |
| 0.5FS10 | 2.5 | — | — | 45 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS10 | 5 | — | — | 65 | 45 | 35 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS10 | 10 | — | — | 65 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS10 | 15 | — | — | — | — | 45 | 40 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS10 | 20 | — | — | — | — | — | — | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS10 | 25 | — | — | — | — | — | — | — | — | 35 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS10 | 30 | — | — | — | — | — | — | — | — | — | 35 | 30 | 30 | 30 | 30 | 30 | — |
| 5P10 / 10P10 | 2.5 | 70 | 80 | 50 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | 30 | 30 | 30 |
| 5P10 / 10P10 | 5 | 110 | 90 | 75 | 60 | 50 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 30 | 30 |
| 5P10 / 10P10 | 10 | — | 145 | 125 | 100 | 80 | 65 | 60 | 50 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 5P10 / 10P10 | 15 | — | — | 140 | 110 | 90 | 80 | 65 | 55 | 45 | 40 | 35 | 35 | 30 | 35 | 30 | 30 |
| 5P10 / 10P10 | 20 | — | — | — | 140 | 115 | 100 | 80 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 | 35 |
| 5P10 / 10P10 | 25 | — | — | — | — | 115 | 115 | 95 | 75 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 |
| 5P10 / 10P10 | 30 | — | — | — | — | — | 135 | 110 | 90 | 75 | 60 | 55 | 50 | 45 | 45 | 40 | 40 |
| 5P20 / 10P20 | 2.5 | 130 | 105 | 90 | 75 | 60 | 50 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 5P20 / 10P20 | 5 | — | 140 | 115 | 90 | 75 | 65 | 55 | 50 | 45 | 40 | 40 | 35 | 35 | 35 | 35 | 35 |
| 5P20 / 10P20 | 10 | — | — | 145 | 125 | 110 | 85 | 75 | 65 | 55 | 50 | 50 | 45 | 45 | 40 | 40 | — |
| 5P20 / 10P20 | 15 | — | — | — | — | 115 | 100 | 85 | 70 | 65 | 60 | 55 | 50 | 50 | 45 | 45 | 45 |
| 5P20 / 10P20 | 20 | — | — | — | — | — | 145 | 125 | 105 | 85 | 75 | 65 | 60 | 55 | 50 | 50 | 50 |
| 5P20 / 10P20 | 25 | — | — | — | — | — | — | — | 130 | 100 | 95 | 85 | 75 | 65 | 60 | 55 | 55 |
| 5P20 / 10P20 | 30 | — | — | — | — | — | — | — | — | 115 | 115 | 95 | 85 | 85 | 70 | 65 | 65 |
| 5P30 / 10P30 | 2.5 | — | 135 | 110 | 85 | 75 | 65 | 55 | 50 | 45 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| 5P30 / 10P30 | 5 | — | — | 135 | 110 | 95 | 80 | 70 | 60 | 50 | 55 | 50 | 50 | 50 | 50 | 50 | 45 |
| 5P30 / 10P30 | 10 | — | — | — | — | — | 130 | 110 | 95 | 75 | 70 | 65 | 60 | 55 | 55 | 50 | 50 |
| 5P30 / 10P30 | 15 | — | — | — | — | — | — | 145 | 125 | 100 | 80 | 75 | 70 | 65 | 60 | 55 | 55 |
| 5P30 / 10P30 | 20 | — | — | — | — | — | — | — | — | 130 | 125 | 110 | 95 | 80 | 75 | 70 | 65 |
| 5P30 / 10P30 | 25 | — | — | — | — | — | — | — | — | — | — | 130 | 110 | 95 | 85 | 75 | 70 |
| 5P30 / 10P30 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | 125 | 110 | 95 | 85 |
Dimension & outline drawing of CGIS2070-I — click image to zoom / view original.
The CGIS2070-I is an indoor epoxy resin cast current transformer for 35kV gas insulated switchgear, designed to IEC 61869 and GB/T 20840. It measures and protects the primary circuit within CGIS assemblies, and its dry epoxy body suits the sealed, controlled interior of the switchgear rather than outdoor exposure.
The core is a ring type with an outer diameter of Ø205mm and an inner diameter of Ø70mm, sized for busbar or cable passage. Accuracy classes cover 0.2FS10 and 0.5FS10 for metering plus 5P10, 10P10, 5P20 and 10P20 for protection, with rated outputs from 2.5VA to 30VA depending on the primary current selected. Protection cores are specified for fault-current service; the applicable ALF and short-time ratings are stated on the nameplate and datasheet [On Request].
Standard ratios and classes ship from stock; non-standard combinations are built to order. Type test and routine test documentation is available [On Request]. The secondary must never be open-circuited while energized, and the secondary circuit is earthed at one point. Verify terminal markings and ratio before energizing.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS2070-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer for Inflatable Switchgear
Professional current transformer dedicated to CGIS inflatable switchgear with multiple accuracy classes and primary current ranges available; secondary lead length and stacked product height support customized configuration.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.