KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS2070
CGIS2070 Current Transformer for Inflatable Switchgear
35kVCGIS2070
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS2070

CGIS2070 Current Transformer for Inflatable Switchgear

Professional current transformer dedicated to CGIS inflatable switchgear with multiple accuracy classes and primary current ranges available; secondary lead length and stacked product height support customized configuration.

Key Engineering Advantages

  • Multi-grade inflatable switchgear dedicated CT; stackable height design; customizable secondary lead length
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS2070

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

CGIS2070 is a dry epoxy resin current transformer for 35kV inflatable switchgear, suitable for metering and protection in RMU applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS2070Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor RMU / inflatable switchgear applications
  • 35kV primary systems
  • Metering and protection with multiple accuracy classes
  • Customized secondary lead length and stackable configurations

Not Recommended For

  • Outdoor substation installations
  • Gas-insulated switchgear (GIS) with SF6 insulation
  • High-voltage transmission lines above 35kV
  • Applications requiring oil or SF6 insulation

Topology & Wiring

Connect secondary terminals 1S1/1S2 for main metering/protection winding; if dual-winding, use 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 and IEEE C57.13 terminal conventions.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating of CGIS2070?

A: The primary voltage is 35kV.

Q: Can CGIS2070 be used outdoors?

A: No, it is designed for indoor inflatable switchgear (RMU) applications.

Q: What insulation type does CGIS2070 use?

A: It uses dry epoxy resin insulation.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS2070
18 cols · 42 rows

CGIS2070 Current Transformer for Gas-Insulated Switchgear — Technical Data

Accuracy classRated output (VA)(40)(50)(60)(75)10012515020025030040050060075010001200
0.2FS10 / 0.5FS102.5nnnn453530303030303030303030
5————704040303030303030303030
10————605040353030303030303030
15—————5040403530303030303030
20————————40353030303030—
25——————————3530303030—
30————————————353030—
0.5FS102.5———453530303030303030303030—
5———654535353030303030303030—
10————6555454035303030303030—
15—————45404035303030303030—
20————————403530303030——
25——————————35303030——
30————————————353030—
5P10 / 10P102.570605040353030252525252525253030
5110907580504540353025252525253030
10——1451251008065605040353030302530
15———1401109080655545403530303035
20————11510080655545403530303035
25—————135115957565554540403535
30——————1351109075655550454540
5P15 / 10P152.595807060504035303025252525253030
513512511090706050454035303030303030
10———1451159580655550404035353535
15————13011090756555505040404040
20—————140110958565605550504545
25——————1351109575756555505045
30———————13011090857565555550
5P20 / 10P202.51301059075605045403535303030303030
5——140115907565555045404035353535
10————145125110907565555045454040
15——————1151008570656055505045
20——————14512510585807565555550
25————————130100958575656560
30—————————11511595857065—
5P30 / 10P302.5———1351108575655550454040404040
5————13511095807060555050505045
10——————1301109575706565605555
15———————145125100907570656060
20—————————130125110958575—
25———————————1301109585—
30————————————12511095—
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS2070 — click image to zoom / view original.

Product Overview

About This Product

CGIS2070

When inflatable switchgear cabinets are tight on space and light-load metering drifts, the CGIS2070 35 kV current transformer is the dedicated answer: a dry epoxy resin cast unit built specifically for this switchgear family, sized to stack vertically so the phase spacing and cable compartment stay clear.

The multi-grade secondary covers 0.2FS10 / 0.5SFS10 / 5P10 / 10P10 / 5P15 / 10P15 at 50/60 Hz, with rated outputs from 2.5 VA to 30 VA depending on the ratio and class selected; the parameter table gives, for example, 45 VA at class 0.2FS10 with a 100 A primary rating. Because it is an indoor dry-type CT, it suits metal-clad and ring-main switchgear rather than outdoor installations. Type and routine test reports are available [On Request] to support verification against the applicable standard.

Never open-circuit the secondary while the primary is energized. Before commissioning, confirm the actual secondary burden in VA does not exceed the rated output for the chosen class, and earth the secondary at one point. Ratio and accuracy-class combinations, secondary lead length and documentation packages are customized per order; delivery is quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS2070 II Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-II

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS2070-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs