CGIS2070 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS2070-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for 35kV CGIS; suitable for metering and protection in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2070-II | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
connect primary through window; secondary terminals 1S1/1S2 for main winding, 2S1-2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point per IEC 61869-2.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: 35kV
Q: What is the insulation type?
A: Dry epoxy resin
Q: What is the inner window diameter?
A: Ø70mm
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | Rated primary current (A) | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| (40) | (50) | (60) | (75) | (100) | (125) | (150) | (200) | (250) | (300) | (400) | (500) | (600) | (750) | (1000) | (1200) | ||
| 0.2FS10 / 0.5FS10 | 2.5 | — | — | — | 45 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 5 | — | — | — | 70 | 40 | 40 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 10 | — | — | — | — | 60 | 50 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 15 | — | — | — | — | — | 50 | 40 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 20 | — | — | — | — | — | — | — | — | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 25 | — | — | — | — | — | — | — | — | — | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 0.2FS10 / 0.5FS10 | 30 | — | — | — | — | — | — | — | — | — | — | 40 | 35 | 30 | 30 | 30 | 30 |
| 0.5FS810 | 2.5 | — | — | 45 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS810 | 5 | — | — | 65 | 45 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS810 | 10 | — | — | 65 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS810 | 15 | — | — | — | — | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS810 | 20 | — | — | — | — | — | — | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS810 | 25 | — | — | — | — | — | — | — | — | 35 | 30 | 30 | 30 | 30 | 30 | 30 | — |
| 0.5FS810 | 30 | — | — | — | — | — | — | — | — | — | 35 | 30 | 30 | 30 | 30 | 30 | — |
| 5P10 / 10P10 | 2.5 | 70 | 60 | 50 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| 5P10 / 10P10 | 5 | 110 | 90 | 75 | 60 | 50 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| 5P10 / 10P10 | 10 | — | 145 | 125 | 100 | 80 | 65 | 60 | 50 | 40 | 35 | 30 | 30 | 30 | 25 | 30 | 30 |
| 5P10 / 10P10 | 15 | — | — | 140 | 110 | 90 | 80 | 65 | 55 | 45 | 40 | 35 | 35 | 30 | 35 | 30 | 35 |
| 5P10 / 10P10 | 20 | — | — | — | 140 | 115 | 100 | 80 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 | 35 |
| 5P10 / 10P10 | 25 | — | — | — | — | 135 | 115 | 95 | 75 | 65 | 55 | 45 | 40 | 40 | 35 | 35 | 35 |
| 5P10 / 10P10 | 30 | — | — | — | — | 135 | 110 | 90 | 75 | 60 | 55 | 50 | 45 | 45 | 40 | 40 | 40 |
| 5P20 / 10P20 | 2.5 | 130 | 105 | 90 | 75 | 60 | 50 | 45 | 40 | 35 | 35 | 30 | 30 | 30 | 30 | 30 | 30 |
| 5P20 / 10P20 | 5 | — | 140 | 115 | 90 | 75 | 65 | 55 | 50 | 45 | 40 | 40 | 35 | 35 | 35 | 35 | 35 |
| 5P20 / 10P20 | 10 | — | — | 145 | 125 | 110 | 85 | 75 | 65 | 55 | 50 | 50 | 45 | 45 | 45 | 40 | 40 |
| 5P20 / 10P20 | 15 | — | — | — | 115 | 100 | 85 | 75 | 70 | 65 | 60 | 55 | 50 | 45 | 45 | 45 | 45 |
| 5P20 / 10P20 | 20 | — | — | — | — | 145 | 120 | 105 | 85 | 80 | 75 | 65 | 60 | 55 | 50 | 50 | 50 |
| 5P20 / 10P20 | 25 | — | — | — | — | — | — | 130 | 100 | 95 | 85 | 75 | 65 | 60 | 55 | 55 | 55 |
| 5P20 / 10P20 | 30 | — | — | — | — | — | — | — | 115 | 115 | 95 | 85 | 75 | 70 | 65 | 65 | 65 |
| 5P30 / 10P30 | 2.5 | — | 135 | 110 | 85 | 75 | 65 | 55 | 50 | 45 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
| 5P30 / 10P30 | 5 | — | — | 135 | 110 | 95 | 80 | 70 | 60 | 55 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| 5P30 / 10P30 | 10 | — | — | — | — | 135 | 110 | 95 | 80 | 75 | 70 | 65 | 60 | 55 | 55 | 55 | 55 |
| 5P30 / 10P30 | 15 | — | — | — | — | — | 145 | 125 | 100 | 90 | 85 | 75 | 70 | 65 | 65 | 65 | 65 |
| 5P30 / 10P30 | 20 | — | — | — | — | — | — | — | 130 | 125 | 110 | 95 | 90 | 85 | 80 | 75 | 75 |
| 5P30 / 10P30 | 25 | — | — | — | — | — | — | — | — | — | 130 | 110 | 95 | 85 | 85 | 85 | 85 |
| 5P30 / 10P30 | 30 | — | — | — | — | — | — | — | — | — | — | 125 | 110 | 95 | 95 | 95 | 95 |
Dimension & outline drawing of CGIS2070-II — click image to zoom / view original.
The CGIS2070-II is a 35 kV indoor current transformer built around a dry epoxy resin casting, a construction that removes the liquid insulation and sealed-tank maintenance associated with oil or SF6 designs while providing a square housing with a Ø70 mm inner window for busbar or cable passage in CGIS gas insulated switchgear. Its secondary architecture pairs metering windings at 0.2FS10 or 0.5FS10 with protection windings at 5P10, 10P10, 5P20 or 10P20, and the parameter table lists rated outputs from 2.5 VA to 30 VA depending on the primary current and accuracy class selected.
As an indoor unit, it is intended for switchgear compartments and busbar current measurement and protection, not for outdoor exposure; the epoxy body and window format suit panel integration where space and creepage are fixed by the switchgear design. Compliance follows the IEC 61869 series, with type test and routine test documentation available [On Request].
Secondary circuits must be earthed at one point, and the secondary must never be open-circuited while the primary is energized; open-circuiting a CT can produce dangerous voltages. Ratio and accuracy class options, drawings and test certificates are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer for Inflatable Switchgear
Professional current transformer dedicated to CGIS inflatable switchgear with multiple accuracy classes and primary current ranges available; secondary lead length and stacked product height support customized configuration.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.