Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX19-10-6G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P),1.0/3P(6P), rated burden 75VA / 150VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX6-10-6RG2M Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P(6P), rated burden 25VA / 60VA / 100VA / 100VA / 300VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-10-10DG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 60VA / 75VA / 400VA / 150VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-10-10G1 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 300VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 15VA / 20VA / 90VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-10-6RG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/3P(6P),0.5/3P(6P),1.0/3P(6P), rated burden 30VA / 75VA / 100VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Current Transformer
Indoor single-phase epoxy resin casting current transformer complying with GB/T20840.1/2 and IEC61869-1/2 standards; rated insulation level 24/65/125kV, rated frequency 50/60Hz, rated secondary current 5A or 1A. Two optional structures: 2s and 4s; primary current optional range 20-2500A. For 2s type: rated output 10-20VA under different accuracy grades, weight 36kg; for 4s type: rated output 15-20VA under different accuracy grades, weight 50kg; short-time thermal current:31.5-100kA, rated dynamic stable current:80-160kA; ambient operating temperature -5℃~+40℃.
10kV Indoor Epoxy Cast Voltage Transformer for State Grid Metering
10kV indoor epoxy resin cast voltage transformer for State Grid metering. Dual windings for metering and residual voltage measurement. Rated insulation level 12/42/75kV, 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting process, low partial discharge, high accuracy. Non-grounded type design, suitable for ungrounded systems. Customizable voltage ratio and accuracy class available.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF10-10-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/6P(3P), rated burden 10VA / 15VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF16-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 30VA / 40VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF19-10-6G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/3P(6P), rated burden 50VA / 60VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZXF51-10-6 Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/0.5/6P(3P), rated burden 30VA / 40VA / 100VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.