Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
Double Cable Current Transformer
Indoor epoxy resin casting double cable current transformer, compliant with GB/T20840.1, GB/T20840.2 and IEC61869-1, IEC61869-2 standards.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LFS8-10 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 10VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Low Voltage Current Transformer 0.5kV
Indoor low voltage current transformer, 0.5kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 60044-1 and GB/T 1208 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
Indoor Low Voltage Bury-plug Current Transformer 0.66kV
Indoor low voltage bury-plug type current transformer, 0.66kV rated, epoxy resin casting type, for current measurement, control and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Bury-plug terminal design with connection pipes, easy and safe wiring. Compact size, transparent dust cover, clean and safe. Wide range of current ratios available. Customizable ratios and specifications.
0.66kV Outdoor Epoxy Cast Busbar-Type Current Transformer for Low Voltage Metering
Outdoor busbar-type current transformer, rated voltage 0.66kV. Designed for low voltage outdoor distribution systems. Rated frequency 50Hz or 60Hz. Ambient temperature range -25°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Outdoor design with weather-resistant construction. Busbar through-core installation, easy to mount on low voltage busbars. Used for current measurement and protection in LV systems.
State Grid Standard 0.66kV Current Transformer
Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 200-600A, accuracy 0.2S/0.5S.
Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV
LDJ8-10 Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LQJ8-10G Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 5VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Cast Current Transformer 10kV
LZZB1-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Epoxy Resin Casting Low Voltage Transformer 0.5kV
Indoor single-phase epoxy resin casting low voltage transformer, 0.5kV rated, for voltage measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, compact size, light weight, suitable for indoor installation. Accuracy classes: 0.5, 1.0, 3.0. Customizable ratios and specifications.