LFS8-10 Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 10VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy cast CT for 10kV systems, suitable for metering and protection up to 1000A primary.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LFS8-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 10VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1 and 1S2 for metering winding (0.2S/0.5S), 2S1 and 2S2 for protection winding (10P). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point. Ensure correct polarity for differential protection. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV highest voltage for equipment, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: What accuracy classes are available?
A: Accuracy combinations include 0.2S/10P and 0.5S/10P, with rated outputs as specified.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSφ=0.8 (0.2S/0.5/10P/10P15) | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 20-200 | 0.2(S)/10P | 10 | 80 I1n | 200 I1n | 16 |
| 300 | 0.2(S)/10P | 10 | 21 | 50 | 16 |
| 400 | 0.2(S)/10P | 10 | 24 | 60 | 16 |
| 500-600 | 0.5/10P | 10 | 30 | 72 | 16 |
| 800 | 0.5/10P | 10 | 40 | 80 | 16 |
| 1000 | 0.5/10P | 10 | 50 | 80 | 16 |
Dimension & outline drawing of LFS8-10 — click image to zoom / view original.
The LFS8-10 is a 10kV indoor single-phase epoxy resin cast current transformer, typically installed in medium-voltage switchgear, ring main units and central cubicles to step primary current down to 5A for metering and protection. Its dry epoxy cast insulation and single-phase construction suit it to these enclosed indoor compartments rather than outdoor service.
Accuracy class options are 0.2S/0.5S with a rated burden of 10VA at 50/60Hz; short-time thermal and dynamic ratings vary by primary current, so confirm the exact figures on the nameplate or official datasheet. The unit weighs 16kg. Standard catalogue ratios cover 20–1000A; non-standard ratios and accuracy classes can be quoted on request. Documentation including datasheets, outline drawings and test reports is available [On Request].
Before energising, verify the secondary burden does not exceed 10VA and earth the secondary at one point. Never open-circuit the secondary while the primary is energised. This indoor CT is not intended for outdoor or exposed installations. Export packing and after-sales support are arranged per order.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.