Indoor low voltage bury-plug type current transformer, 0.66kV rated, epoxy resin casting type, for current measurement, control and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Bury-plug terminal design with connection pipes, easy and safe wiring. Compact size, transparent dust cover, clean and safe. Wide range of current ratios available. Customizable ratios and specifications.
Indoor low-voltage current transformer for 0.66kV systems, suitable for measurement and protection in distribution panels.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LMK8-0.66 | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals are 1S1/1S2 for the main winding; if dual ratio, use 2S1-2S2 for protection winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point per IEC 61869.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the accuracy class of this CT?
A: Available accuracy classes are 0.2, 0.5, and 1.0.
Q: What are the secondary ratings?
A: Secondary ratings are 5A or 1A.
Q: Is this CT suitable for outdoor use?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current (A) | Rated secondary current (A) | Accuracy class (Combined ) | Rated output (VA) | Primary turns (turns) | Overall dimensions | Window dimensions (mm) W×H | ||
|---|---|---|---|---|---|---|---|---|---|
| W | D | H | |||||||
| LMKB-0.66/30 | 10 | 5 | 0.5 | 5 | 6 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 15 | 5 | 0.5 | 5 | 4 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 20 | 5 | 0.5 | 5 | 3 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 25 | 5 | 0.5 | 5 | 2 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 30 | 5 | 0.5 | 5 | 2 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 40 | 5 | 0.5 | 5 | 2 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 50 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 60 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 75 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 100 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 150 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 200 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 250 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/30 | 300 | 5 | 0.5 | 5 | 1 | 56 | 35 | 72 | 26×16 |
| LMKB-0.66/40 | 250 | 5 | 0.5 | 2.5 | 1 | 66 | 43 | 85 | Ø22 40×10 |
| LMKB-0.66/40 | 300 | 5 | 0.5 | 2.5 | 1 | 66 | 43 | 85 | Ø22 40×10 |
| LMKB-0.66/40 | 400 | 5 | 0.5 | 2.5 | 1 | 66 | 43 | 85 | Ø22 40×10 |
| LMKB-0.66/40 | 500 | 5 | 0.5 | 2.5 | 1 | 66 | 43 | 85 | Ø22 40×10 |
| LMKB-0.66/40 | 600 | 5 | 0.5 | 2.5 | 1 | 66 | 43 | 85 | Ø22 40×10 |
| LMKB-0.66/60 | 500 | 5 | 0.5 | 5 | 1 | 85 | 45 | 99 | Ø46 60×21 |
| LMKB-0.66/60 | 600 | 5 | 0.5 | 5 | 1 | 85 | 45 | 99 | Ø46 60×21 |
| LMKB-0.66/60 | 750 | 5 | 0.5 | 5 | 1 | 85 | 45 | 99 | Ø46 60×21 |
| LMKB-0.66/60 | 800 | 5 | 0.5 | 5 | 1 | 85 | 45 | 99 | Ø46 60×21 |
| LMKB-0.66/60 | 1000 | 5 | 0.5 | 5 | 1 | 85 | 45 | 99 | Ø46 60×21 |
| LMKB-0.66/80 | 1000 | 5 | 0.5 | 10 | 1 | 106 | 51 | 127 | Ø50 81×31 |
| LMKB-0.66/80 | 1200 | 5 | 0.5 | 10 | 1 | 106 | 51 | 127 | Ø50 81×31 |
| LMKB-0.66/80 | 1500 | 5 | 0.5 | 10 | 1 | 106 | 51 | 127 | Ø50 81×31 |
| LMKB-0.66/80 | 2000 | 5 | 0.5 | 10 | 1 | 106 | 51 | 127 | Ø50 81×31 |
| LMKB-0.66/100 | 1000 | 5 | 0.5 | 10 | 1 | 127 | 51 | 136 | Ø60 102×31 |
| LMKB-0.66/100 | 1200 | 5 | 0.5 | 10 | 1 | 127 | 51 | 136 | Ø60 102×31 |
| LMKB-0.66/100 | 1500 | 5 | 0.5 | 10 | 1 | 127 | 51 | 136 | Ø60 102×31 |
| LMKB-0.66/100 | 2000 | 5 | 0.5 | 10 | 1 | 127 | 51 | 136 | Ø60 102×31 |
| LMKB-0.66/100 | 2500 | 5 | 0.5 | 10 | 1 | 127 | 51 | 136 | Ø60 102×31 |
| LMKB-0.66/100 | 3000 | 5 | 0.5 | 10 | 1 | 127 | 51 | 136 | Ø60 102×31 |
Dimension & outline drawing of LMK8-0.66 — click image to zoom / view original.
This indoor low-voltage current transformer is built to the IEC 61869 and GB/T 20840 standard family, and that framework defines how its 0.66kV primary circuit is specified, tested and documented for metering and control duty. The unit uses dry epoxy resin insulation applied by vacuum casting or automatic pressure gelation, producing a solid, void-free body that encapsulates the winding and core.
Accuracy classes 0.2, 0.5 and 1.0 are available, with a rated burden of 2.5VA and a 5A or 1A secondary at 50/60Hz; the class chosen governs how tightly ratio and phase error are held across the load range. It sits in the low-voltage bury-plug segment, where the absence of a primary fuse keeps the wiring compact, so fuse-based protection must be provided elsewhere in the scheme. Compliance evidence is available [On Request]. Typical deployment is inside indoor switchgear, ring-main units and central cubicles.
Terminal naming follows the nameplate diagram, with the secondary earthed at one point; never open-circuit the secondary while energized. The indoor enclosure is not for outdoor exposure. Custom ratios and secondary winding configurations are available, with documentation packages and delivery terms quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.