LQJ8-10G Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 5VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy cast CT for 10kV systems; suitable for metering and protection in MV switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LQJ8-10G | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 5VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: Insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse.
Q: Can this CT be used for both metering and protection?
A: Yes, accuracy combination 0.2S/5P or 0.5S/5P supports dual purposes.
Q: What is the weight and ambient temperature range?
A: Net weight 21kg, operating ambient temperature -5°C to +40°C.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) 0.2 (S) | Accuracy class & rated output (VA) 0.5 (S) | Accuracy class & rated output (VA) 5P10 | Accuracy class & rated output (VA) 5P15 | Short-time thermal current I1n (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| 5-15 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 150 I1n | 1 | 375 I1n |
| 20 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 5 | 2 | 12.5 |
| 30-40 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 8 | 2 | 20 |
| 50-80 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 10 | 2 | 25 |
| 75 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 16 | 2 | 40 |
| 100-200 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 20 | 2 | 50 |
| 300-400 | 0.2(S)/5P 0.5(S)/5P | 10 | 10 | 15 | 10 | 25 | 4 | 63 |
| 500-600 | 0.2(S)/5P 0.5(S)/5P | 20 | 20 | 20 | 15 | 31.5 | 4 | 80 |
| 800 | 0.2(S)/5P 0.5(S)/5P | 20 | 20 | 25 | 15 | 31.5 | 4 | 80 |
Dimension & outline drawing of LQJ8-10G — click image to zoom / view original.
The LQJ8-10G is a 10 kV indoor single-phase epoxy resin cast current transformer, used to step primary current down to a 5 A secondary for metering and protection in medium-voltage switchgear. Its dry epoxy cast insulation and single-phase construction suit it to panel mounting inside metal-clad and ring-main units.
Accuracy classes 0.2S and 0.5S are available, with rated outputs of 10 VA in 0.2(S) and 10 VA in 0.5(S), rising to 20 VA at higher primary currents; 5P10 and 5P15 protection cores are offered at 15 VA and 10 VA respectively. Short-time thermal and dynamic ratings scale with the primary current, and the unit weighs 21 kg. Choose it where a single metering-plus-protection core set is sufficient; multi-winding or residual-voltage variants suit more complex schemes.
Compliance follows IEEE C57.13, with routine and type test documentation available [On Request]. Typical indoor deployment includes wind, photovoltaic and storage collector substations. Wire the secondary metering circuit to the marked terminals, earth the secondary at one point, and never open-circuit the secondary while energized. DC or non-standard frequencies are not applicable. OEM branding and customized documentation packages can be quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.