Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 200-600A, accuracy 0.2S/0.5S.
Indoor LV CT for 0.66kV systems, accuracy 0.2S/0.5S, primary 200-600A. Suitable for metering and protection in low-voltage distribution.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LMZ2D-SKX1 | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A | Ratio check at rated frequency |
| Accuracy Class | 0.2S/0.5S | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | 5VA | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window. Secondary terminals are 1S1 and 1S2 (protection winding if present: 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure burden does not exceed 5VA.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the accuracy class of this CT?
A: It has 0.2S for metering and 0.5S for protection.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only.
Q: What is the primary current range?
A: The primary rated current is 200-600A.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current (A) | Rated output (VA) 0.2 class | Rated output (VA) 0.5 class | Primary turns |
|---|---|---|---|---|
| LMZ1D-SKX1 | 75 | 5 | 5 | 1 |
| LMZ2D-SKX2 | 100-150 | 5 | 5 | 1 |
| LMZ3D-SKX1 | 200-600 | 5 | 5 | 1 |
| LMZ4D-SKX1 | 600-800 | 10 | 10 | 1 |
| LMZ4D-SKX1 | 800-1500 | 10 | 10 | 1 |
Dimension & outline drawing of LMZ2D-SKX1 — click image to zoom / view original.
The LMZ2D-SKX1 is an indoor, dry epoxy resin cast current transformer for 0.66 kV systems, converting primary currents of 200–600 A to a 5 A secondary for metering and protection. Its 0.2S/0.5S accuracy classes support revenue settlement, where small errors over time affect billing.
The epoxy cast body provides the dielectric insulation, with creepage, lightning impulse withstand and partial discharge figures stated on the nameplate or official datasheet [On Request]. Compared with oil-immersed or SF6 designs, the dry resin construction avoids liquid or gas handling, which suits indoor switchgear where maintenance access is limited. Rated burden is 5 VA at 50/60 Hz, and the accuracy classes are specified for the metering range.
This unit is intended for indoor installation only and must not be mounted in outdoor exposed locations. Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Secondary terminals follow the nameplate diagram; earth the secondary at one point and never open-circuit it while energized. Verify polarity and ratio before commissioning. Custom ratios, accuracy classes and secondary winding configurations are available, with datasheets, outline drawings and test reports supplied on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.