中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZ2D-SKX1
LMZ2D-SKX1 State Grid Standard 0.66kV Current Transformer
0.66kVLMZ2D-SKX1
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A (0.2S/0.5S)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZ2D-SKX1

LMZ2D-SKX1 State Grid Standard 0.66kV Current Transformer

Indoor epoxy cast LV current transformer, State Grid standard, primary rated current 200-600A, accuracy 0.2S/0.5S.

Key Engineering Advantages

  • 200-600A primary current
  • State Grid standard
  • 0.66kV
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZ2D-SKX1

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A
Metering & Protection Class:0.2S/0.5S
Rated Output Burden:5VA
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor LV CT for 0.66kV systems, accuracy 0.2S/0.5S, primary 200-600A. Suitable for metering and protection in low-voltage distribution.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLMZ2D-SKX1Factory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5ARatio check at rated frequency
Accuracy Class0.2S/0.5SAccuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden5VABurden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low-voltage switchgear and panels
  • Revenue metering with 0.2S accuracy
  • Protection applications with 0.5S accuracy
  • 50/60Hz systems

Not Recommended For

  • Outdoor or high-voltage applications
  • Primary currents above 600A
  • High burden requirements above 5VA
  • DC or high-frequency measurements

Topology & Wiring

Connect primary through the window. Secondary terminals are 1S1 and 1S2 (protection winding if present: 2S1-2S2). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure burden does not exceed 5VA.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the accuracy class of this CT?

A: It has 0.2S for metering and 0.5S for protection.

Q: Can it be used outdoors?

A: No, it is designed for indoor use only.

Q: What is the primary current range?

A: The primary rated current is 200-600A.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZ2D-SKX1
5 cols · 5 rows

LMZ1 (2,3,4)D Series Current Transformer

ModelRated primary current (A)Rated output (VA) 0.2 classRated output (VA) 0.5 classPrimary turns
LMZ1D-SKX175551
LMZ2D-SKX2100-150551
LMZ3D-SKX1200-600551
LMZ4D-SKX1600-80010101
LMZ4D-SKX1800-150010101
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZ2D-SKX1 — click image to zoom / view original.

Product Overview

About This Product

LMZ2D-SKX1

The LMZ2D-SKX1 is an indoor, dry epoxy resin cast current transformer for 0.66 kV systems, converting primary currents of 200–600 A to a 5 A secondary for metering and protection. Its 0.2S/0.5S accuracy classes support revenue settlement, where small errors over time affect billing.

The epoxy cast body provides the dielectric insulation, with creepage, lightning impulse withstand and partial discharge figures stated on the nameplate or official datasheet [On Request]. Compared with oil-immersed or SF6 designs, the dry resin construction avoids liquid or gas handling, which suits indoor switchgear where maintenance access is limited. Rated burden is 5 VA at 50/60 Hz, and the accuracy classes are specified for the metering range.

This unit is intended for indoor installation only and must not be mounted in outdoor exposed locations. Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Secondary terminals follow the nameplate diagram; earth the secondary at one point and never open-circuit it while energized. Verify polarity and ratio before commissioning. Custom ratios, accuracy classes and secondary winding configurations are available, with datasheets, outline drawings and test reports supplied on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs