LDJ8-10 Indoor Single-phase Epoxy Resin Casting Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor 10kV epoxy-cast current transformer for metering and protection in MV switchgear; rated 0.66kV primary, 5A/1A secondary, accuracy 0.2/0.5/1.0.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LDJ8-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary terminals P1/P2 in series with the line. Secondary terminals: 1S1/1S2 for metering winding, 2S1/2S2 for protection winding (if present). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / GB/T 20840 terminal markings.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The insulation level is 12/42/75kV, meaning 12kV highest voltage for equipment, 42kV power-frequency withstand, and 75kV lightning impulse withstand.
Q: Can this CT be used for both metering and protection?
A: Yes, it offers accuracy classes 0.2/0.5/1.0 and optional 0.2S0.5/10P15, suitable for both metering and protection applications.
Q: What is the ambient temperature range?
A: The operating ambient temperature is -5°C to +40°C.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1m (A) | Accuracy classCombined | Rated output (VA) COSφ=0.8 | Short-time thermal current Ith (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 30~400 | 0.2S/0.5/10P15 | 10(15)/20 | 100 I1n | 250 I1n | 33 |
| 30~400 | 0.2S/0.5/10P15 | 10/20/10 | 100 I1n | 250 I1n | 33 |
| 30~400 | 0.2S/0.5/10P20 | 10/20/7.5 | 100 I1n | 250 I1n | 33 |
| 500~800 | 0.2S/0.5/10P15 | 10(15)/20 | 31.5 | 80 | 33 |
| 500~800 | 0.2S/0.5/10P15 | 10/20/15 | 31.5 | 80 | 33 |
| 500~800 | 0.2S/0.5/10P20 | 10/20/10 | 31.5 | 80 | 33 |
| 1000~1500 | 0.2S/0.5/10P15 | 15/20/15 | 31.5 | 80 | 33 |
| 1000~1500 | 0.2S/0.5/10P15 | 15/20/10 | 31.5 | 80 | 33 |
| 1000~1500 | 0.2S/0.5/10P20 | 15/20/10 | 31.5 | 80 | 33 |
| 1000~1500 | 0.2S/0.5/10P15/10P15 | 10/10/7.5/7.5 | 31.5 | 80 | 33 |
Dimension & outline drawing of LDJ8-10 — click image to zoom / view original.
The LDJ8-10 is a 10kV indoor single-phase current transformer built on a dry epoxy resin casting, a construction that removes the liquid-insulation maintenance burden and lets the unit sit directly in medium-voltage switchgear. Its multi-grade winding design covers metering and protection duties in one frame, and the compact cast body helps free panel space in ring-main and central cubicles where depth is at a premium.
Secondary current is available as 5A or 1A, with accuracy classes 0.2/0.5/1.0 and rated outputs of 10(15)/20 VA at COSφ=0.8 for the 30~400 A primary range, where short-time thermal current is 100 I1n and dynamic stability 250 I1n; the 33 kg weight applies across the range. Standard stock ratings suit routine metering and protection, while non-standard ratios and class combinations are quoted to order.
Compliance follows IEC 61869 and GB/T 20840, with type-test and sample support available. The unit is for indoor service in switchgear and ring-main units; before energising, verify the secondary burden in VA against the rated output. Never open-circuit the secondary while the primary is energised, and earth the secondary at one point per the nameplate diagram.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.