Indoor epoxy resin casting double cable current transformer, compliant with GB/T20840.1, GB/T20840.2 and IEC61869-1, IEC61869-2 standards.
Indoor double cable CT for 0.72/3kV systems, epoxy cast, suitable for metering and protection in GIS.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2745 | Factory nameplate marking |
| Primary Voltage | 0.72/3kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50Hz or 60Hz | Per IEC 61869-1 |
| Environment | Ambient: -25°C to +40°C | Per datasheet limits |
Ideal For
Not Recommended For
connect secondary terminals 1S1/1S2 (protection winding 2S1-2S2 if present). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the rated voltage of this CT?
A: 0.72/3kV.
Q: What are the secondary ratings?
A: 5A or 1A.
Q: Is it suitable for outdoor use?
A: No, it is indoor only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Application | Current ratio | Measuring winding Accuracy class & rated burden (VA) 0.2 | Measuring winding Accuracy class & rated burden (VA) 0.2 | Measuring winding Accuracy class & rated burden (VA) 0.5 | Protection winding Accuracy class & rated burden (VA) 10P15 | Protection winding Accuracy class & rated burden (VA) 10P10 | Protection winding Accuracy class & rated burden (VA) 10P5 | Dual-winding Accuracy class & rated burden (VA) | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2 | 0.5 | 10P10 | 10P5 | |||||||||
| CGIS2745 | — | 100/1 | — | — | 2.5 | — | 1.5 | 2.5 | — | — | — | 1.5 |
| — | 150/1 | — | — | 2.5 | — | 1.5 | 3.75 | — | — | — | 2.5 | |
| — | 200/1 | — | — | 3.75 | 5 | 2.5 | 5 | 1.5 | 2.5 | — | 3.75 | |
| — | 300/1 | 2.5 | 5 | 7.5 | 1.5 | 3.75 | 7.5 | 2.5 | 5 | 2.5 | 5 | |
| — | 400/1 | 3.75 | 7.5 | 10 | 2.5 | 5 | 10 | 3.75 | 5 | 2.5 | 5 | |
| — | 500/1 | 5 | 10 | 12.5 | 2.5 | 7.5 | 15 | 5 | 7.5 | 3.75 | 7.5 | |
| — | 600/1 | 7.5 | 12.5 | 15 | 3.75 | 10 | 20 | 7.5 | 10 | 5 | 10 | |
| — | 100/5 | — | — | 2.5 | — | 1.5 | 2.5 | — | — | — | 1.5 | |
| — | 150/5 | — | — | 2.5 | — | 1.5 | 3.75 | — | — | — | 2.5 | |
| — | 200/5 | 2.5 | 5 | 5 | 2.5 | 5 | 5 | 1.5 | 2.5 | 1.5 | 3.75 | |
| — | 300/5 | 2.5 | 5 | 7.5 | 1.5 | 3.75 | 7.5 | 2.5 | 5 | 2.5 | 5 | |
| — | 400/5 | 3.75 | 7.5 | 10 | 2.5 | 5 | 10 | 3.75 | 5 | 2.5 | 5 | |
| — | 500/5 | 5 | 10 | 12.5 | 2.5 | 7.5 | 15 | 5 | 7.5 | 3.75 | 7.5 | |
| — | 600/5 | 7.5 | 12.5 | 45 | 3.75 | 10 | 20 | 7.5 | 10 | 5 | 10 | |
Dimension & outline drawing of CGIS2745 — click image to zoom / view original.
The CGIS2745 is an indoor double cable current transformer for 0.72/3kV systems, converting primary current to a 5A or 1A secondary for metering and protection in medium-voltage switchgear. Its dry epoxy resin casting provides the dielectric insulation, with a rectangular window sized to pass two cables through a single core assembly.
Electrical performance is defined by the approved parameter table: with a 100/1 ratio, the measuring winding delivers class 0.5 at 2.5VA, while the protection winding offers 10P10 at 1.5VA and 10P5 at 2.5VA. The protection core is intended to maintain accuracy under fault currents, helping avoid saturation that could delay tripping. As an indoor unit, it suits metal-clad and ring-main cubicles rather than outdoor exposure, and is built to the IEC 61869 series.
Before energising, perform insulation resistance, polarity and ratio checks. The secondary must never be open-circuited while primary current flows. The CGIS2745 is not intended for DC or non-standard frequencies. Ratio and accuracy-class customisation, documentation packages and lead times are available on request; [On Request] for weight and specific test certificates.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.