中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS2745
CGIS2745 Double Cable Current Transformer
0.72/3kVCGIS2745
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.72/3kV
Secondary Metering (1S1 - 1S2):5A or 1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS2745

CGIS2745 Double Cable Current Transformer

Indoor epoxy resin casting double cable current transformer, compliant with GB/T20840.1, GB/T20840.2 and IEC61869-1, IEC61869-2 standards.

Key Engineering Advantages

  • Indoor epoxy resin casting double cable current transformer
  • rectangular window
  • rated voltage 0.72/3kV
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS2745

Electrical Parameters

Primary Rated Voltage (Un):0.72/3kV
Secondary Winding Currents:5A or 1A
Rated Frequency:50Hz or 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Environmental Class:Ambient: -25°C to +40°C
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor double cable CT for 0.72/3kV systems, epoxy cast, suitable for metering and protection in GIS.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS2745Factory nameplate marking
Primary Voltage0.72/3kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz or 60HzPer IEC 61869-1
EnvironmentAmbient: -25°C to +40°CPer datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor GIS applications
  • Metering and protection in 0.72/3kV systems
  • Double cable configurations
  • Epoxy resin insulated environments

Not Recommended For

  • Outdoor installations
  • High voltage transmission systems
  • Oil or SF6 insulated applications
  • High altitude or severe pollution environments

Topology & Wiring

connect secondary terminals 1S1/1S2 (protection winding 2S1-2S2 if present). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the rated voltage of this CT?

A: 0.72/3kV.

Q: What are the secondary ratings?

A: 5A or 1A.

Q: Is it suitable for outdoor use?

A: No, it is indoor only.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS2745
13 cols · 14 rows

CGIS2745 Dual-Cable Current Transformer

ModelApplicationCurrent ratioMeasuring winding Accuracy class & rated burden (VA) 0.2Measuring winding Accuracy class & rated burden (VA) 0.2Measuring winding Accuracy class & rated burden (VA) 0.5Protection winding Accuracy class & rated burden (VA) 10P15Protection winding Accuracy class & rated burden (VA) 10P10Protection winding Accuracy class & rated burden (VA) 10P5Dual-winding Accuracy class & rated burden (VA)
0.20.510P1010P5
CGIS2745—100/1——2.5—1.52.5———1.5
—150/1——2.5—1.53.75———2.5
—200/1——3.7552.551.52.5—3.75
—300/12.557.51.53.757.52.552.55
—400/13.757.5102.55103.7552.55
—500/151012.52.57.51557.53.757.5
—600/17.512.5153.7510207.510510
—100/5——2.5—1.52.5———1.5
—150/5——2.5—1.53.75———2.5
—200/52.5552.5551.52.51.53.75
—300/52.557.51.53.757.52.552.55
—400/53.757.5102.55103.7552.55
—500/551012.52.57.51557.53.757.5
—600/57.512.5453.7510207.510510
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS2745 — click image to zoom / view original.

Product Overview

About This Product

CGIS2745

The CGIS2745 is an indoor double cable current transformer for 0.72/3kV systems, converting primary current to a 5A or 1A secondary for metering and protection in medium-voltage switchgear. Its dry epoxy resin casting provides the dielectric insulation, with a rectangular window sized to pass two cables through a single core assembly.

Electrical performance is defined by the approved parameter table: with a 100/1 ratio, the measuring winding delivers class 0.5 at 2.5VA, while the protection winding offers 10P10 at 1.5VA and 10P5 at 2.5VA. The protection core is intended to maintain accuracy under fault currents, helping avoid saturation that could delay tripping. As an indoor unit, it suits metal-clad and ring-main cubicles rather than outdoor exposure, and is built to the IEC 61869 series.

Before energising, perform insulation resistance, polarity and ratio checks. The secondary must never be open-circuited while primary current flows. The CGIS2745 is not intended for DC or non-standard frequencies. Ratio and accuracy-class customisation, documentation packages and lead times are available on request; [On Request] for weight and specific test certificates.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs