Indoor low voltage current transformer, 0.5kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 60044-1 and GB/T 1208 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
LMZJ1-0.5 is a low-voltage current transformer for indoor use, suitable for measurement and protection in LV distribution systems. It offers multiple accuracy classes and customizable ratios.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 60044-1 / GB/T 1208 |
| Model Code | LMZJ1-0.5 | Factory nameplate marking |
| Primary Voltage | 0.5kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 60044-1 / GB/T 1208 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For CT secondary wiring, ensure terminals 1S1 and 1S2 are used for the main secondary winding. If a protection winding is present, use 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary circuit at one point only. Follow IEC 61869-2 for terminal markings and safety requirements.
Compliant with: IEC 60044-1 / GB/T 1208
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the rated primary voltage of the LMZJ1-0.5?
A: The rated primary voltage is 0.5kV, suitable for low-voltage systems.
Q: What accuracy classes are available?
A: Accuracy classes 0.2, 0.5, and 1.0 are available for different measurement and protection needs.
Q: Can the current ratio be customized?
A: Yes, the current ratio can be customized to meet specific application requirements.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current (A) | Rated output (VA) 0.2 class | Rated output (VA) 0.5 class | Rated output (VA) 1 class | Primary Turns through core |
|---|---|---|---|---|---|
| LMZ1-0.5 | 5 | 2.5 | 5 | 5 | 30 |
| LMZ1-0.5 | 10 | 2.5 | 5 | 5 | 15 |
| LMZ1-0.5 | 15 | 2.5 | 5 | 5 | 10 |
| LMZ1-0.5 | 20 | 2.5 | 5 | 5 | 8 |
| LMZ1-0.5 | 30 | 2.5 | 5 | 5 | 5 |
| LMZ1-0.5 | 50 | 2.5 | 5 | 5 | 3 |
| LMZ1-0.5 | 75 | 2.5 | 5 | 5 | 2 |
| LMZ1-0.5 | 100 | 2.5 | 5 | 5 | 2 |
| LMZ1-0.5 | 100 | - | - | 5 | 1 |
| LMZ1-0.5 | 150-250 | - | - | 5 | 1 |
| LMZ1-0.5 | 300 | 5 | 5 | 7.5 | 1 |
| LMZ1-0.5 | 400 | 5 | 5 | 7.5 | 1 |
| LMZ(J)1-0.5 | 500-600 | 10 | 10 | 15 | 1 |
| LMZ(J)1-0.5 | 1000-1500 | 20 | 20 | 30 | 1 |
| LMZ(J)1-0.5 | 2000-3000 | 20 | 20 | 30 | 1 |
Dimension & outline drawing of LMZJ1-0.5 — click image to zoom / view original.
This is an indoor low-voltage current transformer for panel and switchgear installations, rated 0.5kV and used to step primary current down to a 5A or 1A secondary for metering and control. Its dry epoxy resin insulation and compact moulded body suit it to space-constrained LV compartments, with the primary conductor passed through the window in a single turn.
The secondary is available as 5A or 1A, with accuracy classes 0.2, 0.5 and 1.0 and rated outputs of 10VA to 30VA depending on the primary current selected. The epoxy resin body provides the dielectric strength required for 0.5kV indoor service, and the design follows IEC 60044-1 and GB/T 1208 at 50/60Hz. For trade-settlement metering, calibration certificates can be supplied [On Request].
Typical deployment covers LV distribution in metallurgical, mining, cement and chemical plants, where non-sinusoidal loads may call for derating. The secondary circuit must never be open-circuited while energized, and one point of the secondary should be earthed. Ratio and accuracy-class combinations can be customized, with documentation packages and delivery terms confirmed at enquiry.
Same product family, different ratings — compare before you specify.
0.66kV Outdoor Epoxy Cast Busbar-Type Current Transformer for Low Voltage Metering
Outdoor busbar-type current transformer, rated voltage 0.66kV. Designed for low voltage outdoor distribution systems. Rated frequency 50Hz or 60Hz. Ambient temperature range -25°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Outdoor design with weather-resistant construction. Busbar through-core installation, easy to mount on low voltage busbars. Used for current measurement and protection in LV systems.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.