中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLMZJ1-0.5
LMZJ1-0.5 Indoor Low Voltage Current Transformer 0.5kV
0.5kVLMZJ1-0.5
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.5kV
Secondary Metering (1S1 - 1S2):5A/1A (0.2/0.5/1.0)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LMZJ1-0.5

LMZJ1-0.5 Indoor Low Voltage Current Transformer 0.5kV

Indoor low voltage current transformer, 0.5kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 60044-1 and GB/T 1208 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.

Key Engineering Advantages

  • LV current transformer
  • 0.5kV
  • epoxy resin
  • multiple ratios
  • compact size
  • IEC 60044-1 standard
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LMZJ1-0.5

Electrical Parameters

Primary Rated Voltage (Un):0.5kV
Secondary Winding Currents:5A/1A
Metering & Protection Class:0.2/0.5/1.0
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 60044-1 / GB/T 1208
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LMZJ1-0.5 is a low-voltage current transformer for indoor use, suitable for measurement and protection in LV distribution systems. It offers multiple accuracy classes and customizable ratios.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 60044-1 / GB/T 1208
Model CodeLMZJ1-0.5Factory nameplate marking
Primary Voltage0.5kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class0.2/0.5/1.0Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 60044-1 / GB/T 1208Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor low-voltage switchgear and panel mounting
  • Current measurement and protection in LV distribution systems
  • Applications requiring accuracy classes 0.2, 0.5, or 1.0
  • Retrofitting existing LV panels with compact CTs
  • Custom current ratio requirements

Not Recommended For

  • Outdoor installations without additional protection
  • High-voltage systems above 1kV
  • Applications requiring revenue-grade metering with class 0.1 or better
  • Environments with high humidity or corrosive atmospheres without proper enclosure
  • Direct connection to high-voltage busbars

Topology & Wiring

For CT secondary wiring, ensure terminals 1S1 and 1S2 are used for the main secondary winding. If a protection winding is present, use 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary circuit at one point only. Follow IEC 61869-2 for terminal markings and safety requirements.

Standards & Compliance

Compliant with: IEC 60044-1 / GB/T 1208

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the rated primary voltage of the LMZJ1-0.5?

A: The rated primary voltage is 0.5kV, suitable for low-voltage systems.

Q: What accuracy classes are available?

A: Accuracy classes 0.2, 0.5, and 1.0 are available for different measurement and protection needs.

Q: Can the current ratio be customized?

A: Yes, the current ratio can be customized to meet specific application requirements.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LMZJ1-0.5
6 cols · 15 rows

LMZ (J)1-0.5 Series Current Transformer — Technical Data

ModelRated primary current (A)Rated output (VA) 0.2 classRated output (VA) 0.5 classRated output (VA) 1 classPrimary Turns through core
LMZ1-0.552.55530
LMZ1-0.5102.55515
LMZ1-0.5152.55510
LMZ1-0.5202.5558
LMZ1-0.5302.5555
LMZ1-0.5502.5553
LMZ1-0.5752.5552
LMZ1-0.51002.5552
LMZ1-0.5100--51
LMZ1-0.5150-250--51
LMZ1-0.5300557.51
LMZ1-0.5400557.51
LMZ(J)1-0.5500-6001010151
LMZ(J)1-0.51000-15002020301
LMZ(J)1-0.52000-30002020301
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LMZJ1-0.5 — click image to zoom / view original.

Product Overview

About This Product

LMZJ1-0.5

This is an indoor low-voltage current transformer for panel and switchgear installations, rated 0.5kV and used to step primary current down to a 5A or 1A secondary for metering and control. Its dry epoxy resin insulation and compact moulded body suit it to space-constrained LV compartments, with the primary conductor passed through the window in a single turn.

The secondary is available as 5A or 1A, with accuracy classes 0.2, 0.5 and 1.0 and rated outputs of 10VA to 30VA depending on the primary current selected. The epoxy resin body provides the dielectric strength required for 0.5kV indoor service, and the design follows IEC 60044-1 and GB/T 1208 at 50/60Hz. For trade-settlement metering, calibration certificates can be supplied [On Request].

Typical deployment covers LV distribution in metallurgical, mining, cement and chemical plants, where non-sinusoidal loads may call for derating. The secondary circuit must never be open-circuited while energized, and one point of the secondary should be earthed. Ratio and accuracy-class combinations can be customized, with documentation packages and delivery terms confirmed at enquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LMZJ1-0.66W 0.66kV Outdoor Epoxy Cast Busbar-Type Current Transformer for Low Voltage Metering
0.66kV
Current Transformer50/60Hz

LMZJ1-0.66W

0.66kV Outdoor Epoxy Cast Busbar-Type Current Transformer for Low Voltage Metering

Outdoor busbar-type current transformer, rated voltage 0.66kV. Designed for low voltage outdoor distribution systems. Rated frequency 50Hz or 60Hz. Ambient temperature range -25°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Outdoor design with weather-resistant construction. Busbar through-core installation, easy to mount on low voltage busbars. Used for current measurement and protection in LV systems.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1765

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs