Outdoor busbar-type current transformer, rated voltage 0.66kV. Designed for low voltage outdoor distribution systems. Rated frequency 50Hz or 60Hz. Ambient temperature range -25°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Outdoor design with weather-resistant construction. Busbar through-core installation, easy to mount on low voltage busbars. Used for current measurement and protection in LV systems.
Outdoor busbar-type CT for 0.66kV LV systems; suitable for metering and protection in outdoor distribution.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LMZJ1-0.66W | Factory nameplate marking |
| Primary Voltage | 0.66kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Outdoor busbar-type through-core; Ambient: -25°C ~ +40°C | Per datasheet limits |
Ideal For
Not Recommended For
connect secondary terminals 1S1 and 1S2 for metering; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the rated voltage of this CT?
A: 0.66kV.
Q: Is it suitable for outdoor installation?
A: Yes, it is designed for outdoor use with weather-resistant construction.
Q: What standards does it comply with?
A: IEC 61869 and GB/T 20840.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated primary current (A) | Rated output (VA) | ||
|---|---|---|---|---|
| 0.2 | 0.5 | 1 | ||
| LMZ1-0.66W | 5-200 | — | 5 | 10 |
| LMZ1-0.66W | 300-400 | 2.5 | 5 | 10 |
| LMZJ1-0.66W | 500-1200 | 5 | 10 | 10 |
Dimension & outline drawing of LMZJ1-0.66W — click image to zoom / view original.
When low-voltage outdoor distribution boards need accurate metering without the bulk of a wound-primary transformer, this busbar-type current transformer addresses the problem by passing the primary conductor straight through its core. The LMZJ1-0.66W is rated for 0.66kV systems at 50/60Hz and is intended for current measurement in low-voltage outdoor metering circuits.
Its dry epoxy resin body encapsulates the winding, and each unit is checked at the factory for ratio and polarity before dispatch; routine-test documentation is available [On Request]. The approved parameter table lists a primary current range of 500-1200A with rated outputs of 5VA at class 0.2, 10VA at class 0.5 and 10VA at class 1. Secondary current is 1A or 5A [On Request]. Because it carries no primary fuses, the protection scheme relies on upstream devices, so it suits metering duty rather than fault interruption.
Compliance with IEC 61869 and GB/T 20840 supports calibration certificates for trade-settlement metering where required. Typical deployment includes outdoor distribution and renewable-energy collection points. Never open-circuit the secondary while energized. Sample and type-test support are available on request.
Same product family, different ratings — compare before you specify.
Indoor Low Voltage Current Transformer 0.5kV
Indoor low voltage current transformer, 0.5kV rated, epoxy resin casting type, for current measurement and protection in low voltage distribution systems. Complies with IEC 60044-1 and GB/T 1208 standards. Wide range of current ratios available, multiple accuracy classes 0.2, 0.5, 1.0. Compact size, easy installation, suitable for switchgear and panel mounting. Customizable ratios and specifications.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1765 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.