LZZB1-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
LZZB1-10 is a 10kV indoor epoxy cast current transformer for metering and protection, suitable for medium voltage switchgear panels.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LZZB1-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5/1.0 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of LZZB1-10?
A: The insulation level is 12/42/75kV, meaning 12kV highest voltage for equipment, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q: What are the available accuracy classes?
A: Accuracy classes include 0.2S/0.2S, 0.2S/0.5S, and 0.2S/5P10, with rated output 15VA per class.
Q: Can it be used for outdoor applications?
A: No, it is designed for indoor use only, as it is epoxy cast and not weatherproof.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) | Short-time thermal current (kA/S) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 20 | 0.2/5(0.2/5) 0.2/5(0.5/5) 0.5/5(0.5/5) 0.5/5(10P/10) | 15 | 100 | 250 | — |
| 300 | — | 15 | 24 | 60 | — |
| 400 | — | 15 | 32 | 80 | 15 |
| 500 | — | 15 | 40 | 100 | — |
| 600-800 | — | 15 | 48 | 120 | — |
Dimension & outline drawing of LZZB1-10 — click image to zoom / view original.
The LZZB1-10 is an indoor single-phase epoxy cast current transformer for 10kV systems, designed to step primary current down to 5A or 1A for metering and protection. It follows IEC 61869 and GB/T 20840, placing it within a recognised framework for routine and type testing.
Its dry epoxy resin body encapsulates the windings, and factory checks include routine tests, ratio and polarity verification, with partial discharge screening available [On Request]. Accuracy classes 0.2, 0.5 and 1.0 are offered with a 15VA rated burden, and the secondary is available as 5A or 1A to suit different relay and meter inputs. Within the range, the choice between accuracy classes and secondary currents depends on the burden and metering or protection requirements; this unit combines both functions. A full document package including datasheet, outline drawing and test reports can be supplied.
Typical deployment is in indoor distribution boards for heavy industry such as metallurgy, mining, cement and chemical plants. Earth the secondary at one point and bond it equipotentially; never open-circuit the secondary while energised. Custom ratios and accuracy classes are available, and export packing with after-sales support is offered; weight is 15kg.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.