Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
10kV Indoor Epoxy Cast Built-in Voltage Transformer R-Type for Pole-Mounted Circuit Breaker
10kV/6kV indoor single-phase epoxy resin cast voltage transformer, R-type. Special R-type bushing design for pole-mounted circuit breaker integration. Rated insulation level 12/42/75kV and 7.2/32/60kV. Rated frequency 50/60Hz. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, compact design, easy installation in switchgear. Provides reliable voltage measurement and protection signals. Customizable voltage ratio and accuracy class.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX9-10-6AG Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2/6P(3P),0.5/6P(3P),1.0/6P(3P),0.2/0.5/6P(3P), rated burden 10VA / 10VA / 50VA / 50VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV
JDZW-10 6GY Outdoor Single-phase Epoxy Resin Casting Voltage Transformer 10kV 6kV (JDZW-10-6GY) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV/6kV, accuracy class 0.2/0.5/1.0. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
JDZX15-15R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 15kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 3×10VA(0.2),3×30VA(0.5),100VA(3P/6P). Design: insulation level 18/55/105kV, Dry Epoxy Resin, 50/60Hz operation.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
JLSZV6-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to GB/T 17201.
Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
JDZX15-6R-CQ Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer
JDZX15-6R2-CQ Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 6kV, accuracy class 0.2 / 0.5. Design: insulation level 7.2/32/60kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX16-10-6W Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P, rated burden 30VA / 100VA / 180VA / 100VA / 800VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV
JLSZV8-10W Outdoor Three-phase Epoxy Resin Casting Combined Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to GB/T 17201.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZX16-10-6W2G Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 3P, rated burden 80VA / 150VA / 250VA / 100VA / 1200VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.
Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer
JSZF-10-6G Indoor Three-phase Anti-ferroresonance Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 0.1kV, accuracy class 0.2, 0.5, 1.0, 6P(3P), rated burden 15VA / 30VA / 50VA / 100VA / 1000VA. Design: insulation level 12/42/75kV,7.2/32/60kV, Dry Epoxy Resin, 50Hz or 60Hz operation.