LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
LZZB9-12-35-168-CGIS is a dry epoxy resin current transformer for CGIS gas-insulated switchgear, suitable for 10kV systems with 50/60Hz. It meets IEC 61869-1/2 and GB/T20840 standards.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | LZZB9-12-35-168-CGIS | Factory nameplate marking |
| Primary Voltage | 12kV/35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | 12/42/75, 40.5/95/185kV | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50Hz / 60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers, connect secondary terminals 1S1 and 1S2 for the main winding; if a protection winding is present, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary winding at one point. Ensure correct polarity and observe shorting and grounding procedures during installation and maintenance.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What are the insulation levels of this CT?
A: The insulation level is 0.72/3kV, meaning the highest voltage for equipment is 0.72kV, and the power-frequency withstand voltage is 3kV. This is for the low-voltage insulation, not the primary system voltage.
Q: Can this CT be used for both 12kV and 35kV systems?
A: Yes, the description states it supports 12kV and 35kV voltage grades, but the primary voltage specified is 10kV. For higher system voltages, please confirm the specific model and ratings.
Q: Is this CT suitable for outdoor use?
A: No, it is designed for indoor CGIS gas-insulated switchgear applications. Outdoor use would require additional protection against environmental factors.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current I1n (A) | Accuracy classCombined | Accuracy class & rated output (VA) COSΦ=0.8 12KV | Accuracy class & rated output (VA) COSΦ=0.8 35KV | Short-time thermal current (kA/S) | Rated dynamic current Idyn (kA) | Weight (kg) |
|---|---|---|---|---|---|---|
| 20,30,40 | 0.2/0.2 | 15/15 | 10/10 | 150 I1n | 375 I1n | 55 |
| 50,75,100,150 | 0.2/0.5 | 15/20 | 10/15 | 31.5 | 80 | 55 |
| 200 | 0.2/10P10 | 15/20 | 10/15 | 45 | 112.5 | 55 |
| 300,400,500 | 0.5/10P10 | 20/20 | 15/10 | 63 | 130 | 55 |
| 600,800 | 0.2/0.2 | 20/20 | 15/15 | 80 | 160 | 55 |
| 1000,1200,1250 | 0.2/0.5 | 20/25 | 15/20 | 80 | 160 | 55 |
| 1000,1200,1250 | 0.2/10P10 | 20/20 | 15/15 | 80 | 160 | 55 |
| 1000,1200,1250 | 0.5/10P10 | 25/20 | 20/15 | 80 | 160 | 55 |
Dimension & outline drawing of LZZB9-12-35-168-CGIS — click image to zoom / view original.
This current transformer is a 12kV/35kV indoor unit for CGIS gas-insulated switchgear, stepping primary current down to 5A or 1A for metering and protection. Its dry epoxy resin insulation and compact format suit the limited space inside inflatable cabinets and substation rooms, where a smaller footprint simplifies panel layout. Insulation levels are 12/42/75kV and 40.5/95/185kV across the two voltage grades, with 50Hz/60Hz operation and rated burdens of 10VA and 15VA; accuracy class and ratio are stated on the nameplate.
The two voltage grades let one design family serve standard 12kV and 35kV switchgear projects, while non-standard ratios, classes or burdens are quoted as custom builds. Type-test and routine-test documentation, including calibration certificates for metering duty, are available [On Request]. Typical deployment covers rail transit, data centres, hospitals and water utilities. On site, follow the nameplate terminal diagram, earth the secondary at one point and verify the metering circuit before energising; the secondary must never be open-circuited while the primary is energised.
DC or non-standard frequencies are outside its scope. Sample and type-test support is offered, with lead times confirmed at enquiry.
Same product family, different ratings — compare before you specify.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-35-198-CGIS is an indoor epoxy resin cast current transformer dedicated to 35kV CGIS gas-insulated (inflatable) switchgear cabinets. It is built for compact CGIS panels and offers excellent thermal and dynamic stability, with configurable current ratios and accuracy classes for metering and protection. Design and testing follow GB/T 20840.1, GB/T 20840.2, IEC 61869-1 and IEC 61869-2.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.