中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZB9-12-35-168-CGIS
LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear
12kV/35kVLZZB9-12-35-168-CGIS
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 12kV/35kV
Secondary Metering (1S1 - 1S2):5A or 1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZB9-12-35-168-CGIS

LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Key Engineering Advantages

  • Two voltage grades optional
  • excellent thermal and dynamic current resistance
  • dedicated for CGIS inflatable cabinet scenarios
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZB9-12-35-168-CGIS

Electrical Parameters

Primary Rated Voltage (Un):12kV/35kV
Secondary Winding Currents:5A or 1A
Rated Frequency:50Hz / 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):12/42/75, 40.5/95/185kV
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LZZB9-12-35-168-CGIS is a dry epoxy resin current transformer for CGIS gas-insulated switchgear, suitable for 10kV systems with 50/60Hz. It meets IEC 61869-1/2 and GB/T20840 standards.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZB9-12-35-168-CGISFactory nameplate marking
Primary Voltage12kV/35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)12/42/75, 40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz / 60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor CGIS gas-insulated switchgear (GIS) applications
  • 10kV power systems with 50/60Hz frequency
  • Metering and protection circuits requiring 5A or 1A secondary output
  • Environments needing dry epoxy resin insulation with high thermal and dynamic current resistance

Not Recommended For

  • Outdoor installations without additional weatherproofing
  • Systems above 35kV voltage class
  • Applications requiring oil or gas insulation instead of epoxy resin
  • DC systems or non-standard frequencies outside 50/60Hz

Topology & Wiring

For current transformers, connect secondary terminals 1S1 and 1S2 for the main winding; if a protection winding is present, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary winding at one point. Ensure correct polarity and observe shorting and grounding procedures during installation and maintenance.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What are the insulation levels of this CT?

A: The insulation level is 0.72/3kV, meaning the highest voltage for equipment is 0.72kV, and the power-frequency withstand voltage is 3kV. This is for the low-voltage insulation, not the primary system voltage.

Q: Can this CT be used for both 12kV and 35kV systems?

A: Yes, the description states it supports 12kV and 35kV voltage grades, but the primary voltage specified is 10kV. For higher system voltages, please confirm the specific model and ratings.

Q: Is this CT suitable for outdoor use?

A: No, it is designed for indoor CGIS gas-insulated switchgear applications. Outdoor use would require additional protection against environmental factors.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZB9-12-35-168-CGIS
7 cols · 8 rows

12KV, 35KV — Parameter Table

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSΦ=0.8 12KVAccuracy class & rated output (VA) COSΦ=0.8 35KVShort-time thermal current (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
20,30,400.2/0.215/1510/10150 I1n375 I1n55
50,75,100,1500.2/0.515/2010/1531.58055
2000.2/10P1015/2010/1545112.555
300,400,5000.5/10P1020/2015/106313055
600,8000.2/0.220/2015/158016055
1000,1200,12500.2/0.520/2515/208016055
1000,1200,12500.2/10P1020/2015/158016055
1000,1200,12500.5/10P1025/2020/158016055
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZB9-12-35-168-CGIS — click image to zoom / view original.

Product Overview

About This Product

LZZB9-12-35-168-CGIS

This current transformer is a 12kV/35kV indoor unit for CGIS gas-insulated switchgear, stepping primary current down to 5A or 1A for metering and protection. Its dry epoxy resin insulation and compact format suit the limited space inside inflatable cabinets and substation rooms, where a smaller footprint simplifies panel layout. Insulation levels are 12/42/75kV and 40.5/95/185kV across the two voltage grades, with 50Hz/60Hz operation and rated burdens of 10VA and 15VA; accuracy class and ratio are stated on the nameplate.

The two voltage grades let one design family serve standard 12kV and 35kV switchgear projects, while non-standard ratios, classes or burdens are quoted as custom builds. Type-test and routine-test documentation, including calibration certificates for metering duty, are available [On Request]. Typical deployment covers rail transit, data centres, hospitals and water utilities. On site, follow the nameplate terminal diagram, earth the secondary at one point and verify the metering circuit before energising; the secondary must never be open-circuited while the primary is energised.

DC or non-standard frequencies are outside its scope. Sample and type-test support is offered, with lead times confirmed at enquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZB9-35-198-CGIS Current Transformer for CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

LZZB9-35-198-CGIS

Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-35-198-CGIS is an indoor epoxy resin cast current transformer dedicated to 35kV CGIS gas-insulated (inflatable) switchgear cabinets. It is built for compact CGIS panels and offers excellent thermal and dynamic stability, with configurable current ratios and accuracy classes for metering and protection. Design and testing follow GB/T 20840.1, GB/T 20840.2, IEC 61869-1 and IEC 61869-2.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 20840.1
View Specs
LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear
35kV
Current Transformer50Hz / 60Hz

LZZB9-35-198K2-CGIS

Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs