中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLZZB9-35-198K2-CGIS
LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear
35kVLZZB9-35-198K2-CGIS
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2):5A or 1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LZZB9-35-198K2-CGIS

LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Key Engineering Advantages

  • Adopt K2 structural design
  • two dimension options for 50-1250A and 1500-2500A
  • suitable for 35kV CGIS gas-insulated switchgear
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LZZB9-35-198K2-CGIS

Electrical Parameters

Primary Rated Voltage (Un):35kV
Secondary Winding Currents:5A or 1A
Rated Frequency:50Hz / 60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Insulation Level (BIL):40.5/95/185kV
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LZZB9-35-198K2-CGIS is a dry epoxy resin current transformer for 35kV CGIS gas-insulated switchgear, with primary voltage 10kV and secondary 5A or 1A. It is suitable for metering and protection in indoor gas-insulated switchgear applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeLZZB9-35-198K2-CGISFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)40.5/95/185kVPower-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50Hz / 60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 35kV CGIS gas-insulated switchgear
  • Indoor ring main units and substations
  • Current measurement and protection in medium voltage networks
  • Applications requiring dry-type insulation with epoxy resin

Not Recommended For

  • Outdoor installations without additional protection
  • High voltage systems above 35kV
  • Oil-immersed or SF6 gas insulated transformers (non-CGIS)
  • Direct connection to overhead lines without proper enclosure

Topology & Wiring

For current transformers, connect secondary terminals 1S1 and 1S2 for the main winding; if a protection winding is present, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary winding at one point. Ensure proper shorting before disconnecting the secondary circuit. Follow IEC 61869-2 and GB/T20840.2 for installation and testing.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating of this CT?

A: The primary voltage is 10kV, but it is designed for use in 35kV CGIS switchgear.

Q: What are the secondary output options?

A: The secondary output can be 5A or 1A, depending on the required ratio.

Q: Is this CT suitable for outdoor use?

A: No, it is designed for indoor CGIS gas-insulated switchgear applications.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LZZB9-35-198K2-CGIS
10 cols · 9 rows

LZZB9-35/198K2/CGIS Current Transformer for Gas-Insulated Switchgear — Technical Data

Rated primary current I1n (A)Accuracy classCombinedAccuracy class & rated output (VA) COSφ=0.8Accuracy class & rated output (VA) COSφ=0.8Accuracy class & rated output (VA) COSφ=0.8Accuracy class & rated output (VA) COSφ=0.8Accuracy class & rated output (VA) COSφ=0.8Short-time thermal current Ith (kA/S)Rated dynamic current Idyn (kA)Weight (kg)
20-500.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P1520252015150/1n375/1n62
75-1500.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P1520252015150/1n375/1n62
2000.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P152025201531.58062
3000.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P152025201545112.562
4000.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P152025201545112.562
5000.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P152025201545112.562
600-8000.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P20203025206313062
1000-12500.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P20203025208016062
1500-25000.2(5)/0.5(5) 0.2(5)/5P 0.5(5)/5P 0.5(5)/5P/5P202030252010015062
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LZZB9-35-198K2-CGIS — click image to zoom / view original.

Product Overview

About This Product

LZZB9-35-198K2-CGIS

The LZZB9-35-198K2-CGIS is a 35kV current transformer built for CGIS gas-insulated switchgear, converting primary current to a 5A or 1A secondary for metering and protection. Its dry epoxy resin insulation reaches 40.5/95/185kV, and the K2 structural design is offered in two dimension options covering 50-1250A and 1500-2500A primary ratings.

Metering and protection cores are combined in one housing: accuracy classes 0.2(S), 0.5(S), 5P10 and 5P15 are available with rated outputs of 15VA, 20VA or 25VA, matched to the connected secondary burden at 50Hz or 60Hz. Short-time thermal current and rated dynamic current follow the primary rating, with the unit weighing 62kg.

Intended for indoor installation inside 35kV CGIS switchgear, this unit suits substation, rail and industrial power distribution where a compact resin-cast CT is required. Secondary circuits must never be open-circuited while energized, and the secondary should be earthed at one point per the nameplate terminal diagram. Verify secondary burden against the rated VA before energization. Compliance evidence to IEEE C57.13 and other standards is available [On Request], as are ratio and accuracy-class customization, document packages and delivery terms.

Other Models in This Series

Same product family, different ratings — compare before you specify.

LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear
12kV/35kV
Current Transformer50Hz / 60Hz

LZZB9-12-35-168-CGIS

Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LZZB9-35-198-CGIS Current Transformer for CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

LZZB9-35-198-CGIS

Current Transformer for CGIS Gas Insulated Switchgear

LZZB9-35-198-CGIS is an indoor epoxy resin cast current transformer dedicated to 35kV CGIS gas-insulated (inflatable) switchgear cabinets. It is built for compact CGIS panels and offers excellent thermal and dynamic stability, with configurable current ratios and accuracy classes for metering and protection. Design and testing follow GB/T 20840.1, GB/T 20840.2, IEC 61869-1 and IEC 61869-2.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceGB/T 20840.1
View Specs
CGIS2070 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2070-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs