LZZB9-35-198-CGIS is an indoor epoxy resin cast current transformer dedicated to 35kV CGIS gas-insulated (inflatable) switchgear cabinets. It is built for compact CGIS panels and offers excellent thermal and dynamic stability, with configurable current ratios and accuracy classes for metering and protection. Design and testing follow GB/T 20840.1, GB/T 20840.2, IEC 61869-1 and IEC 61869-2.
LZZB9-35-198-CGIS is a 10kV epoxy resin cast current transformer for CGIS gas insulated switchgear, ideal for metering and protection in compact indoor RMU applications.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | GB/T 20840.1, GB/T 20840.2, IEC 61869-1, IEC 61869-2 |
| Model Code | LZZB9-35-198-CGIS | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | GB/T 20840.1, GB/T 20840.2, IEC 61869-1, IEC 61869-2 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing; secondary terminals are 1S1/1S2 for metering, and if present, 2S1-2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: GB/T 20840.1, GB/T 20840.2, IEC 61869-1, IEC 61869-2
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: The primary voltage is 10kV.
Q: Is this CT suitable for outdoor use?
A: No, it is designed for indoor CGIS gas insulated switchgear applications.
Q: What standards does it comply with?
A: It complies with GB/T20840.1, GB/T20840.2, IEC61869-1, and IEC61869-2.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) | Short-time thermal current (kA) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|
| 20,30,40,50 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 150 1m | 375 1m | — |
| 75,100,150 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 150 1m | 375 1m | — |
| 200 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 31.5 | 80 | — |
| 300 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 45 | 112.5 | 54 |
| 400 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 45 | 112.5 | 54 |
| 500 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 63 | 160 | — |
| 600-800 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 63 | 160 | — |
| 1000-1250 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 15 20 15 10 | 80 | 160 | — |
| 1500-2000 | 0.2/0.2 0.2/0.5 0.5/0.5 0.5/10P 0.5/10P10 0.5/10P15 | 20 20 25 20 | 100 | 150 | — |
Dimension & outline drawing of LZZB9-35-198-CGIS — click image to zoom / view original.
The LZZB9-35-198-CGIS is a 35 kV dry epoxy resin current transformer built for metering and protection in 35 kV CGIS gas-insulated switchgear, where its 198 mm width and 54 kg mass suit compact inflatable cabinets and help address the space and saturation concerns of dense switchgear layouts.
Its dry epoxy resin insulation is rated 40.5/95/185 kV, and the unit is intended for indoor service within the cabinet enclosure. Accuracy combinations include 0.2/0.2, 0.2/0.5, 0.2/10P10, 0.5/10P10, 0.2/10P15 and 0.5/10P15, with rated outputs of 15–20 VA by class and ratio. Short-time thermal current reaches 31.5 kA at 200 A primary and 45 kA at 300–400 A, with corresponding dynamic stability, supporting thermal and dynamic withstand in compact substations.
Compliance follows GB/T 20840.1 and GB/T 20840.2, with IEC 61869-1 and IEC 61869-2 also cited; type test documentation is available [On Request]. The secondary must never be open-circuited while energized, and the secondary circuit is earthed at one point with equipotential bonding before commissioning checks. DC or non-standard frequencies are not applicable. Ratio and class variants, sample support and documentation packages are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-35-198K2-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV, secondary voltage 5A or 1A. Design: insulation level 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Current Transformer for CGIS Gas Insulated Switchgear
LZZB9-12-35-168-CGIS Current Transformer for CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV/35kV, secondary voltage 5A or 1A. Design: insulation level 12/42/75, 40.5/95/185kV, Dry Epoxy Resin, 50Hz / 60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2070 I is an indoor epoxy resin casting current transformer designed for CGIS gas-insulated switchgear at 35kV. It is available with accuracy classes 0.2FS10, 0.5SFS10, 5P10, 10P10, 5P20 and 10P20. The epoxy casting has an outer diameter of Ø205mm and a through (inner) diameter of Ø70mm for busbar installation, and is rated for 50/60Hz operation. Metering classes (0.2FS10, 0.5SFS10) and protection classes (5P10, 10P10, 5P20, 10P20) cover both measurement and relay protection inside CGIS panels.