KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • AI Is Hungry for Power: How Many Instrument Transformers Does an AI Data Center Need?
  • From 110 kV to the GPU: CTs and PTs Across an AI Data Center Power Chain
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
High Voltage Equipment Directory

Voltage & Current Transformers

Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.

Category3
Voltage
Showing 382 Potential Transformer models
JSZY18-10FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-10FR

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZY18-10FR Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZXM15-6-CQ Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXM15-6-CQ

Indoor Single-phase Metal Armoured Epoxy Resin Casting Voltage Transformer

Indoor single-phase metal armoured epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz, weight 28kg, aluminum hull sealed structure.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ18-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
6 kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ18-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/0.1kV, rated frequency 50/60Hz; accuracy class rated output:30VA(0.2),60VA(0.5),100VA(1.0); limiting thermal output of secondary winding 600VA; product weight:31kg; ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZX15-10R2-CQ Indoor Single-phase Metal ArmouReddish  Brown Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX15-10R2-CQ

Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer

JDZX15-10R2-CQ Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZU18-6R Indoor Single-phase Epoxy Resin Casting Voltage Transformer
6 kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZU18-6R

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/0.1/0.22kV, rated frequency 50/60Hz; accuracy class rated output:20VA(0.2),40VA(0.5),60VA(1.0); maximum power output 500VA; product weight:31kg; ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JSZY18-10FR-2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZY18-10FR-2

Indoor Three-phase Epoxy Resin Casting Voltage Transformer

JSZY18-10FR-2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZXF15-20R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Insulation-separated Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZXF15-20R-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Insulation-separated Voltage Transformer

JDZXF15-20R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Insulation-separated Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2/3P(6P)、0.5/3P(6P), rated burden 3×10VA(0.2),3×30VA(0.5),100VA(3P/6P). Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2/3P(6P)、0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden3×10VA(0.2),3×30VA(0.5),100VA(3P/6P)
View Specs
JDZX15-20R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer
20kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX15-20R-CQ

Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer

JDZX15-20R-CQ Indoor Single-phase Fuse-built-in Metal Armoured Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2/0.5/3P(6P), rated burden 3×10VA(0.2),3×15VA(0.5),100VA(3P/6P). Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2/0.5/3P(6P)
Insulation TypeDry Epoxy Resin
Rated Burden3×10VA(0.2),3×15VA(0.5),100VA(3P/6P)
View Specs
JDZX15-10R(CQ) Indoor Single-phase Metal ArmouReddish  Brown Epoxy Resin Casting Voltage Transformer
10kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZX15-10R-CQ

Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer

JDZX15-10R(CQ) Indoor Single-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer (JDZX15-10R-CQ) is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, accuracy class 0.2 / 0.5. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.

Accuracy Class0.2 / 0.5
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
JDZ18-6BR Indoor Single-phase Epoxy Resin Casting Voltage Transformer
6 kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JDZ18-6BR

Indoor Single-phase Epoxy Resin Casting Voltage Transformer

Indoor single-phase epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated voltage ratio 6/0.1/0.22kV, rated frequency 50/60Hz; accuracy class rated output:40VA(0.2),100VA(0.5),150VA(1.0); maximum power output 1000VA; product weight:43kg; ambient operating temperature -5℃~+40℃.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
LKZB-Φ100 to Φ250 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker
6kV-35kV
Current Transformer50/60Hz

LKZB-100-250

LKZB-Φ100 to Φ250 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker

Split-core zero sequence current transformer specially designed for 6kV-35kV indoor cable head outlets. Can be installed without power interruption - split into two halves and bolted together. Rated frequency 50Hz or 60Hz. Inner diameter range Φ100 to Φ250, suitable for various cable sizes. Compliant with IEC 61869 and GB/T 20840 standards. Hot-line installation capability saves downtime and maintenance cost. Epoxy resin cast construction, reliable performance.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
ComplianceIEC 61869
View Specs
JSZV15-6R Indoor Three-phase Metal ArmouReddish  Brown Epoxy Resin Casting Voltage Transformer
6kV
Voltage Transformer (VT) / Potential Transformer (PT)50/60Hz

JSZV15-6R

Indoor Three-phase Metal ArmouReddish Brown Epoxy Resin Casting Voltage Transformer

Indoor three-phase metal armouReddish Brown epoxy resin casting voltage transformer complying with GB/T20840.1/3 and IEC61869-1/3 standards; rated insulation level 7.2/32/60kV, rated frequency 50/60Hz; product weight:55kg; ambient operating temperature -5℃~+40℃, multiple optional accuracy grades and winding schemes available.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
← Prev1…2627282930…32Next →