Filter through our complete catalog of IEC 61869-3 & IEEE C57.13 compliant instrument transformers (0.5kV to 35kV): Cast Epoxy Resin Dry-Type Voltage Transformers (VT/PT), Current Transformers (CT) and Combined CT+VT units.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV29-10R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Resin Casting Voltage Transformer
JDZ18-20R Indoor Single-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2 / 0.5. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV2-20R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2 / 0.5. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Outdoor Three-phase Silicone Rubber Voltage Transformer 6kV with Fuse
Outdoor three-phase silicone rubber composite insulation voltage transformer, 6kV rated, with primary fuse, for voltage measurement and protection in three-phase power distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Silicone rubber construction, excellent weather resistance, anti-UV, anti-pollution, suitable for harsh outdoor environments. Accuracy classes: 0.2, 0.5, 3P. Customizable ratios and specifications.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV18-20R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 20kV, accuracy class 0.2 / 0.5. Design: insulation level 24/65/125kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV18-10DR2 Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Three-phase Epoxy Resin Casting Voltage Transformer
JSZV19-10R Indoor Three-phase Epoxy Resin Casting Voltage Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV. Design: insulation level 12/42/75kV, Dry Epoxy Resin, 50/60Hz operation.
Indoor Low Voltage Current Transformer 0.66kV Busbar Type
Indoor low voltage current transformer, 0.66kV rated, type III, busbar fixed installation, for current measurement and metering in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Large capacity, high accuracy, suitable for three-phase vertical busbar arrangement. Easy installation, wide range of current ratios available. Customizable ratios and specifications.
Indoor Single-phase Epoxy Resin Casting Low Voltage Transformer 0.66kV
Indoor single-phase epoxy resin casting low voltage transformer, 0.66kV rated, for voltage measurement and protection in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Epoxy resin construction, compact size, light weight, suitable for indoor installation. Accuracy classes: 0.5, 1.0, 3.0. Customizable ratios and specifications.
10kV Indoor Epoxy Cast Single-Phase Current Transformer for Switchgear Metering & Protection
Low voltage indoor epoxy resin cast current transformer, rated 0.72/3kV. Suitable for low voltage distribution systems. Rated frequency 50/60Hz, secondary current 5A or 1A. Ambient temperature range -40°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, reliable performance, easy installation. Customizable current ratio and accuracy class.
Indoor Single-phase Epoxy Resin Casting Current Transformer
LA-10Q Indoor Single-phase Epoxy Resin Casting Current Transformer is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A, accuracy class 0.2S/0.5S, rated burden 5VA. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor Single-phase Epoxy Cast Current Transformer 10kV
LZZB2-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.