KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTALH-0.66III
ALH-0.66III Indoor Low Voltage Current Transformer 0.66kV Busbar Type
0.66kVALH-0.66III
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.66kV
Secondary Metering (1S1 - 1S2):5A/1A (0.2/0.5)
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:ALH-0.66III

ALH-0.66III Indoor Low Voltage Current Transformer 0.66kV Busbar Type

Indoor low voltage current transformer, 0.66kV rated, type III, busbar fixed installation, for current measurement and metering in low voltage distribution systems. Complies with IEC 61869 and GB/T 20840 standards. Large capacity, high accuracy, suitable for three-phase vertical busbar arrangement. Easy installation, wide range of current ratios available. Customizable ratios and specifications.

Key Engineering Advantages

  • LV current transformer type III
  • 0.66kV
  • busbar type
  • large capacity high accuracy
  • easy install
  • customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: ALH-0.66III

Electrical Parameters

Primary Rated Voltage (Un):0.66kV
Secondary Winding Currents:5A/1A
Metering & Protection Class:0.2/0.5
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Standards Conformance:IEC 61869 / GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

ALH-0.66III is a 0.66kV indoor busbar-type current transformer for accurate metering and measurement in LV distribution. It suits panelboards and switchgear with vertical busbars.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869 / GB/T 20840
Model CodeALH-0.66IIIFactory nameplate marking
Primary Voltage0.66kVRated voltage test (IEC 61869-1/3)
Secondary Current5A/1ARatio check at rated frequency
Accuracy Class0.2/0.5Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869 / GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor LV switchgear and panelboards
  • Busbar mounting in three-phase vertical arrangement
  • Current measurement and energy metering
  • 0.66kV systems with 50/60Hz
  • Accuracy classes 0.2/0.5 applications

Not Recommended For

  • Outdoor installations
  • High voltage systems above 1kV
  • Cable or through-type mounting
  • Protection applications requiring class 5P/10P
  • DC systems

Topology & Wiring

Connect primary busbar through the window. Secondary terminals: 1S1 and 1S2 for metering (if dual ratio, 2S1-2S2 for protection). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point. Follow IEC 61869 / GB/T 20840 for wiring and safety.

Standards & Compliance

Compliant with: IEC 61869 / GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the rated primary voltage?

A: 0.66kV.

Q: What are the available secondary currents?

A: 5A or 1A.

Q: What accuracy classes are available?

A: 0.2 and 0.5.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

ALH-0.66III
8 cols · 42 rows

ALH-0.66III Series Current Transformer — Technical Data

ModelCurrent ratioAccuracy classRated burden (VA)Overall dimensionsWindow dimensions (mm) A×E
WDH
ALH-0.66III30100-150/50.52.573508812×32
ALH-0.66III30200-250/50.5573508812×32
ALH-0.66III30300/50.5573508812×32
ALH-0.66III30400-600/50.5/0.22.573508812×32
ALH-0.66III30150/10.52.573508812×32
ALH-0.66III30200-300/10.5573508812×32
ALH-0.66III30400-600/10.5573508812×32
ALH-0.66III50400-600/50.5/0.210755612016×52
ALH-0.66III501000/50.5/0.215755612016×52
ALH-0.66III50150/10.52.5755612016×52
ALH-0.66III50200-400/10.55755612016×52
ALH-0.66III50500-1000/10.510755612016×52
ALH-0.66III80400-750/50.5/0.21099.556139.533×62
ALH-0.66III80800/50.5/0.21099.556139.533×62
ALH-0.66III801000/50.5/0.21599.556139.533×62
ALH-0.66III801200-1500/50.5/0.21599.556139.533×62
ALH-0.66III802000/50.5/0.22599.556139.533×62
ALH-0.66III80250-600/10.5599.556139.533×62
ALH-0.66III80800-1000/10.51099.556139.533×62
ALH-0.66III801200-2000/10.5/0.21599.556139.533×62
ALH-0.66III100750-800/50.5/0.2109956163.533×83
ALH-0.66III1001000/50.5/0.2159956163.533×83
ALH-0.66III1001200-1500/50.5/0.2159956163.533×83
ALH-0.66III1002000/50.5/0.2209956163.533×83
ALH-0.66III100400-1000/10.5109956163.533×83
ALH-0.66III1001200-2000/10.5159956163.533×83
ALH-0.66III120800/50.5/0.2101045618933×103
ALH-0.66III1201000/50.5/0.2151045618933×103
ALH-0.66III1201200-1500/50.5/0.2151045618933×103
ALH-0.66III1202000-5000/50.5/0.2201045618933×103
ALH-0.66III120500-1000/10.5101045618933×103
ALH-0.66III1201200-2000/10.5151045618933×103
ALH-0.66III1202500-5000/10.5201045618933×103
ALH-0.66III200600/50.5/0.210124.55621453×123
ALH-0.66III2001000/50.5/0.215124.55621453×123
ALH-0.66III2001200-1500/50.5/0.215124.55621453×123
ALH-0.66III2002000-5000/50.5/0.220124.55621453×123
ALH-0.66III200600-1000/10.510124.55621453×123
ALH-0.66III2001200-5000/10.515124.55621453×123
ALH-0.66III3001200-1500/50.5/0.215129.554.521957×132
ALH-0.66III3002000-5000/50.5/0.220129.554.521957×132
ALH-0.66III3001200-5000/10.515129.554.521957×132
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of ALH-0.66III — click image to zoom / view original.

Product Overview

About This Product

ALH-0.66III

The ALH-0.66III is an indoor, busbar-type low-voltage current transformer rated 0.66 kV, intended to step primary current down to 5 A or 1 A for metering and revenue settlement, where accuracy class 0.2 or 0.5 directly affects billing integrity. Its dry epoxy resin insulation and busbar window construction suit panel builders and metering specialists working in low-voltage switchgear.

Accuracy classes 0.2/0.5 are available, with rated burdens spanning 2.5 VA to 15 VA depending on the current ratio selected, for example 400-600/5 at 10 VA or 1000/5 at 15 VA in the ALH-0.66III50 frame. The unit is built to IEC 61869 and GB/T 20840 at 50/60 Hz, and calibration certificates for trade-settlement metering can be supplied [On Request]. Typical indoor deployment includes rail transit substations, data centres, hospitals and water-treatment plants.

Secondary circuits must be earthed at one point and never open-circuited while the primary is energised; verify terminal polarity and ratio before energising. The transformer is not suitable for DC or non-standard frequencies. Standard ratios are stocked, while custom ratios, accuracy classes and sample or type-test documentation are available on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs