KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTLRZ-10
LRZ-10 10kV Indoor Epoxy Cast Single-Phase Current Transformer for Switchgear Metering & Protection
0.72/3kVLRZ-10
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 0.72/3kV
Secondary Metering (1S1 - 1S2):5A or 1A ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:LRZ-10

LRZ-10 10kV Indoor Epoxy Cast Single-Phase Current Transformer for Switchgear Metering & Protection

Low voltage indoor epoxy resin cast current transformer, rated 0.72/3kV. Suitable for low voltage distribution systems. Rated frequency 50/60Hz, secondary current 5A or 1A. Ambient temperature range -40°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, reliable performance, easy installation. Customizable current ratio and accuracy class.

Key Engineering Advantages

  • 0.72/3kV low voltage current transformer
  • epoxy cast
  • wide temperature range
  • IEC compliant
  • easy installation
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: LRZ-10

Electrical Parameters

Primary Rated Voltage (Un):0.72/3kV
Secondary Winding Currents:5A or 1A
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Environmental Class:Indoor epoxy resin cast; Ambient: -40°C ~ +40°C
Standards Conformance:IEC 61869, GB/T 20840
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

Low voltage distribution system
GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

LRZ-10 is a low-voltage indoor current transformer for metering and protection in LV distribution systems, with secondary ratings of 5A or 1A.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent TransformerIEC 61869, GB/T 20840
Model CodeLRZ-10Factory nameplate marking
Primary Voltage0.72/3kVRated voltage test (IEC 61869-1/3)
Secondary Current5A or 1ARatio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
StandardsIEC 61869, GB/T 20840Certified to listed standards
Frequency50/60HzPer IEC 61869-1
EnvironmentIndoor epoxy resin cast; Ambient: -40°C ~ +40°CPer datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Low voltage (0.72/3kV) indoor switchgear and distribution panels
  • Metering and protection applications in LV networks
  • Environments with ambient temperatures from -40°C to +40°C
  • Systems requiring IEC 61869 and GB/T 20840 compliance

Not Recommended For

  • High voltage (above 3kV) systems
  • Outdoor installations without additional protection
  • Gas-insulated switchgear (GIS) applications
  • DC systems or non-sinusoidal waveforms

Topology & Wiring

For current transformers: Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure correct polarity for metering and protection.

Standards & Compliance

Compliant with: IEC 61869, GB/T 20840

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating of LRZ-10?

A: The primary voltage rating is 0.72/3kV, suitable for low voltage systems.

Q: What secondary currents are available?

A: Secondary current options are 5A or 1A.

Q: Is LRZ-10 suitable for outdoor use?

A: No, it is designed for indoor use with epoxy resin cast insulation.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

LRZ-10
2 cols · 5 rows

LRZ-10 Series Current Transformer — Technical Data

ParameterValue
Product performance complies with standardsGB/T20840.1, 2 and IEC61869-1, 2 standards
Rated voltage0.72/3kV
Rated frequency50Hz or 60Hz
Rated secondary current5A or 1A
Ambient temperature-40℃~+40℃
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of LRZ-10 — click image to zoom / view original.

Product Overview

About This Product

LRZ-10

The LRZ-10 is a 0.72/3kV indoor epoxy-cast single-phase current transformer for metering and protection in low-voltage distribution systems. Its dry epoxy resin cast insulation forms the primary dielectric, and the design follows GB/T 20840.1 and 20840.2 as well as IEC 61869-1 and 61869-2. Rated frequency is 50Hz or 60Hz, and the secondary is 5A or 1A.

Accuracy class, rated output in VA and short-time thermal ratings are stated on the nameplate and the official datasheet [On Request]. The unit is intended for indoor switchgear and ring-main units, where the epoxy body suits the ambient range of -40℃ to +40℃. It is not for outdoor open-air installation, and the secondary must never be open-circuited while the primary is energized.

Secondary terminals follow the nameplate marking; earth the secondary at one point and check the metering circuit polarity before energization. Ratio and secondary-output variants are available on request, with test reports and drawings supplied with the quotation.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs