Low voltage indoor epoxy resin cast current transformer, rated 0.72/3kV. Suitable for low voltage distribution systems. Rated frequency 50/60Hz, secondary current 5A or 1A. Ambient temperature range -40°C to +40°C. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, reliable performance, easy installation. Customizable current ratio and accuracy class.
LRZ-10 is a low-voltage indoor current transformer for metering and protection in LV distribution systems, with secondary ratings of 5A or 1A.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869, GB/T 20840 |
| Model Code | LRZ-10 | Factory nameplate marking |
| Primary Voltage | 0.72/3kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869, GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Indoor epoxy resin cast; Ambient: -40°C ~ +40°C | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers: Connect primary winding in series with the line. Secondary terminals are 1S1 and 1S2 for the main winding; if a protection winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Ensure correct polarity for metering and protection.
Compliant with: IEC 61869, GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating of LRZ-10?
A: The primary voltage rating is 0.72/3kV, suitable for low voltage systems.
Q: What secondary currents are available?
A: Secondary current options are 5A or 1A.
Q: Is LRZ-10 suitable for outdoor use?
A: No, it is designed for indoor use with epoxy resin cast insulation.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Parameter | Value |
|---|---|
| Product performance complies with standards | GB/T20840.1, 2 and IEC61869-1, 2 standards |
| Rated voltage | 0.72/3kV |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Ambient temperature | -40℃~+40℃ |
Dimension & outline drawing of LRZ-10 — click image to zoom / view original.
The LRZ-10 is a 0.72/3kV indoor epoxy-cast single-phase current transformer for metering and protection in low-voltage distribution systems. Its dry epoxy resin cast insulation forms the primary dielectric, and the design follows GB/T 20840.1 and 20840.2 as well as IEC 61869-1 and 61869-2. Rated frequency is 50Hz or 60Hz, and the secondary is 5A or 1A.
Accuracy class, rated output in VA and short-time thermal ratings are stated on the nameplate and the official datasheet [On Request]. The unit is intended for indoor switchgear and ring-main units, where the epoxy body suits the ambient range of -40℃ to +40℃. It is not for outdoor open-air installation, and the secondary must never be open-circuited while the primary is energized.
Secondary terminals follow the nameplate marking; earth the secondary at one point and check the metering circuit polarity before energization. Ratio and secondary-output variants are available on request, with test reports and drawings supplied with the quotation.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.