LZZB2-10 Indoor Single-phase Epoxy Cast Current Transformer 10kV is designed for metering and protection in power systems. Key ratings: primary voltage 10kV, secondary voltage 5A/1A, accuracy class 0.2/0.5. Design: Dry Epoxy Resin, 50/60Hz operation. Conforms to IEC 61869 / GB/T 20840.
Indoor 10kV epoxy cast current transformer for medium voltage switchgear, suitable for metering and protection up to 630A.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869 / GB/T 20840 |
| Model Code | LZZB2-10 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A/1A | Ratio check at rated frequency |
| Accuracy Class | 0.2/0.5 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869 / GB/T 20840 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary in series with the line. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection (if present). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / IEEE C57.13 conventions.
Compliant with: IEC 61869 / GB/T 20840
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the rated insulation level?
A: Rated insulation level is 12/42/75kV, meaning 12kV system voltage, 42kV power-frequency withstand, 75kV lightning impulse withstand.
Q: What accuracy classes are available?
A: Accuracy classes include 0.2S/0.2S, 0.2S/0.5S, and 0.5S/5P10, with rated outputs as specified.
Q: Can it be used outdoors?
A: No, it is designed for indoor use only.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Rated primary current (A) | Accuracy classCombined | Accuracy class & rated output (VA) 0.2 (5) | Accuracy class & rated output (VA) 0.5 (5) | Accuracy class & rated output (VA) 5P10/5P15 | Short-time thermal current (kA/S) | Rated dynamic current (kA) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 20-100 | 0.2(5)/0.2(5) 0.2(5)/0.5(5) 0.2(5)/5P10 0.5(5)/5P10 | 15 | 15 | 15 | 100 1m | 250 1m | — |
| 200 | 0.2(5)/0.2(5) 0.2(5)/0.5(5) 0.2(5)/5P10 0.5(5)/5P10 | 15 | 15 | 15 | 20 | 40 | — |
| 300 | 0.2(5)/0.2(5) 0.2(5)/0.5(5) 0.2(5)/5P10 0.5(5)/5P10 | 15 | 15 | 15 | 24 | 60 | — |
| 400 | 0.2(5)/0.2(5) 0.2(5)/0.5(5) 0.2(5)/5P10 0.5(5)/5P10 | 15 | 15 | 15 | 30 | 75 | — |
| 500 | 0.2(5)/0.2(5) 0.2(5)/0.5(5) 0.2(5)/5P10 0.5(5)/5P10 | 15 | 15 | 15 | 40 | 100 | — |
| 600-800 | 0.2(5)/0.2(5) 0.2(5)/0.5(5) 0.2(5)/5P10 0.5(5)/5P10 | 15 | 15 | 15 | 48 | 120 | — |
Dimension & outline drawing of LZZB2-10 — click image to zoom / view original.
The LZZB2-10 is a 10kV indoor single-phase epoxy cast current transformer, built to IEC 61869 and GB/T 20840, that steps primary current down to a 5A or 1A secondary for metering and protection in medium-voltage switchgear. Its dry epoxy resin body insulates the primary and secondary windings, with dielectric design margins and creepage details documented in the official datasheet and on the nameplate.
The unit delivers accuracy classes 0.2 and 0.5 with a rated burden of 15VA, and short-time thermal and dynamic ratings that scale with primary current, from 100kA/1s and 250kA dynamic at 20-100A to 48kA/1s and 120kA dynamic at 600-800A. Standard stocked ratios suit routine metering and protection, while non-standard ratios and class combinations are available for project-specific needs, supported by type-test evidence and calibration certificates for trade-settlement metering.
It is intended for indoor medium-voltage switchgear, ring main units and center-mounted cubicles. Before energizing, verify the secondary burden does not exceed 15VA, earth the secondary at one point, and never open-circuit the secondary while the primary is live. Harmonic or non-sinusoidal loads require derating review. Samples and type-test support are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.