KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS1021S
CGIS1021S Current Transformer for Inflatable Switchgear
35kVCGIS1021S
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS1021S

CGIS1021S Current Transformer for Inflatable Switchgear

CGIS1021S Current Transformer for Inflatable Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • Three-phase integrated structure
  • independent dimension design
  • customizable outgoing wire parameters
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS1021S

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Suitable for 35kV CGIS inflatable switchgear applications requiring three-phase integrated current measurement with customizable secondary leads.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS1021SFactory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 35kV ring main unit (RMU) applications
  • Indoor gas-insulated switchgear (GIS) panels
  • Three-phase integrated current measurement
  • Custom secondary lead configurations
  • 50/60Hz power systems

Not Recommended For

  • Outdoor substation installations
  • Voltage measurement applications
  • High-accuracy metering beyond specified grades
  • Non-epoxy insulation environments
  • Systems above 35kV

Topology & Wiring

Connect secondary terminals 1S1/1S2 for main protection winding, and 2S1-2S2 for additional winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Ensure proper shorting before disconnecting load.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: The primary voltage is 35kV.

Q: What insulation type is used?

A: Dry epoxy resin insulation.

Q: Can the secondary leads be customized?

A: Yes, secondary lead specifications are customizable.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS1021S
9 cols · 30 rows

CGIS7515S, 9817S, 1021S Current Transformer for Gas-Insulated Switchgear — Technical Data

Accuracy classCombinedRated primary current (A)200300400500600700800
0.2/5P102.5304050607080—
560708090100110—
108590100110120130—
15105110120130140150—
20120130140150160170—
25135150160170180190—
0.5/5P102.5304050607080—
560708090100110—
108590100110120130—
15105110120130140150—
20120130140150160170—
25135150160170180190—
5P10/5P102.5304050607080—
560708090100110—
108590100110120130—
15105110120130140150—
20120130140150160170—
25135150160170180190—
5P15/5P152.5405060708090—
58090100110120130—
10110120130140150160—
15135150160170180190—
20160170180190200210—
25180190200210220230—
5P20/5P202.55060708090100—
5100110120130140150—
10140150160170180190—
15170180190200210220—
20200210220230240250—
25220230240250260270—
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS1021S — click image to zoom / view original.

Product Overview

About This Product

CGIS1021S

The CGIS1021S is a 35kV current transformer built for inflatable switchgear, where it measures primary current and supplies scaled secondary signals to protection and metering devices. Its dry epoxy resin insulation removes the liquid-handling and leakage concerns of oil-filled designs, and the three-phase integrated structure packs all three phases into one compact, independently dimensioned body.

Accuracy classes cover 0.2FS10, 0.5FS10, 5P10, 10P10, 5P15 and 10P15 at 50/60Hz, so metering and protection duties can be specified from one family. Where project-specific ratings are required, rated outputs in VA, rated primary currents and short-time thermal ratings should be taken from the nameplate or the official datasheet [On Request]. Compliance follows the GB/T 20840 series, with routine ratio, polarity and insulation tests offered as documentary evidence.

Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Earth the secondary at one point and short it before opening the circuit; never open-circuit an energized secondary. The unit is not intended for DC or non-standard frequencies. Custom ratios, accuracy classes and secondary winding configurations are available, with the document package and delivery terms confirmed at inquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs