CGIS1021S Current Transformer for Inflatable Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Suitable for 35kV CGIS inflatable switchgear applications requiring three-phase integrated current measurement with customizable secondary leads.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS1021S | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect secondary terminals 1S1/1S2 for main protection winding, and 2S1-2S2 for additional winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Ensure proper shorting before disconnecting load.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: The primary voltage is 35kV.
Q: What insulation type is used?
A: Dry epoxy resin insulation.
Q: Can the secondary leads be customized?
A: Yes, secondary lead specifications are customizable.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy classCombined | Rated primary current (A) | 200 | 300 | 400 | 500 | 600 | 700 | 800 |
|---|---|---|---|---|---|---|---|---|
| 0.2/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 10 | 85 | 90 | 100 | 110 | 120 | 130 | — | |
| 15 | 105 | 110 | 120 | 130 | 140 | 150 | — | |
| 20 | 120 | 130 | 140 | 150 | 160 | 170 | — | |
| 25 | 135 | 150 | 160 | 170 | 180 | 190 | — | |
| 0.5/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 10 | 85 | 90 | 100 | 110 | 120 | 130 | — | |
| 15 | 105 | 110 | 120 | 130 | 140 | 150 | — | |
| 20 | 120 | 130 | 140 | 150 | 160 | 170 | — | |
| 25 | 135 | 150 | 160 | 170 | 180 | 190 | — | |
| 5P10/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | — |
| 5 | 60 | 70 | 80 | 90 | 100 | 110 | — | |
| 10 | 85 | 90 | 100 | 110 | 120 | 130 | — | |
| 15 | 105 | 110 | 120 | 130 | 140 | 150 | — | |
| 20 | 120 | 130 | 140 | 150 | 160 | 170 | — | |
| 25 | 135 | 150 | 160 | 170 | 180 | 190 | — | |
| 5P15/5P15 | 2.5 | 40 | 50 | 60 | 70 | 80 | 90 | — |
| 5 | 80 | 90 | 100 | 110 | 120 | 130 | — | |
| 10 | 110 | 120 | 130 | 140 | 150 | 160 | — | |
| 15 | 135 | 150 | 160 | 170 | 180 | 190 | — | |
| 20 | 160 | 170 | 180 | 190 | 200 | 210 | — | |
| 25 | 180 | 190 | 200 | 210 | 220 | 230 | — | |
| 5P20/5P20 | 2.5 | 50 | 60 | 70 | 80 | 90 | 100 | — |
| 5 | 100 | 110 | 120 | 130 | 140 | 150 | — | |
| 10 | 140 | 150 | 160 | 170 | 180 | 190 | — | |
| 15 | 170 | 180 | 190 | 200 | 210 | 220 | — | |
| 20 | 200 | 210 | 220 | 230 | 240 | 250 | — | |
| 25 | 220 | 230 | 240 | 250 | 260 | 270 | — |
Dimension & outline drawing of CGIS1021S — click image to zoom / view original.
The CGIS1021S is a 35kV current transformer built for inflatable switchgear, where it measures primary current and supplies scaled secondary signals to protection and metering devices. Its dry epoxy resin insulation removes the liquid-handling and leakage concerns of oil-filled designs, and the three-phase integrated structure packs all three phases into one compact, independently dimensioned body.
Accuracy classes cover 0.2FS10, 0.5FS10, 5P10, 10P10, 5P15 and 10P15 at 50/60Hz, so metering and protection duties can be specified from one family. Where project-specific ratings are required, rated outputs in VA, rated primary currents and short-time thermal ratings should be taken from the nameplate or the official datasheet [On Request]. Compliance follows the GB/T 20840 series, with routine ratio, polarity and insulation tests offered as documentary evidence.
Typical deployment is heavy-industry distribution in metallurgy, mining, cement and chemical plants. Earth the secondary at one point and short it before opening the circuit; never open-circuit an energized secondary. The unit is not intended for DC or non-standard frequencies. Custom ratios, accuracy classes and secondary winding configurations are available, with the document package and delivery terms confirmed at inquiry.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.