中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS1455
CGIS1455 Current Transformer for Inflatable Switchgear
35kVCGIS1455
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS1455

CGIS1455 Current Transformer for Inflatable Switchgear

Special current transformer for CGIS inflatable cabinets, multiple accuracy grades and primary current specifications available, customizable lead length and stackable product height.

Key Engineering Advantages

  • Multi-precision inflatable-cabinet dedicated CT
  • height stackable by coil quantity
  • secondary outgoing length customizable
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS1455

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

CGIS1455 is a dry-type current transformer for 35kV inflatable switchgear, ideal for metering and protection in RMU applications.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS1455Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • Indoor RMU / inflatable switchgear (CGIS) applications
  • 35kV primary systems with 50/60Hz
  • Metering and protection with multiple accuracy classes
  • Custom secondary lead lengths and stackable height configurations

Not Recommended For

  • Outdoor substation installations (not weatherproof)
  • Gas-insulated switchgear (GIS) with SF6 insulation (dry type only)
  • High-voltage transmission lines above 35kV
  • Applications requiring oil or gas insulation

Topology & Wiring

Connect secondary terminals 1S1/1S2 for main metering/protection winding; if dual ratio, use 2S1-2S2 for additional winding. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only to avoid circulating currents.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: The primary voltage is 35kV.

Q: Can the secondary lead length be customized?

A: Yes, the secondary outgoing length is customizable.

Q: Is this CT suitable for outdoor use?

A: No, it is designed for indoor inflatable switchgear (CGIS) applications.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS1455
15 cols · 42 rows

CGIS1455 Current Transformer for Gas-Insulated Switchgear — Technical Data

Accuracy classRated output (VA)Rated primary current (A)
40506075100125150200250300400500600
0.2FS10/0.5FS102.5—————8580503530303030
0.2FS10/0.5FS105—————13090705040353030
0.2FS10/0.5FS1010——————1501157555453530
0.2FS10/0.5FS1015———————16010070554540
0.2FS10/0.5FS1020———————1258555453535
0.2FS10/0.5FS1025————————10570554540
0.2FS10/0.5FS1030————————12085705550
0.5FS102.5——115805040353030252525—
0.5FS105———1207560453530302525—
0.5FS1010————12090705040353030—
0.5FS1015—————120906555453530—
0.5FS1020——————115805550403535
0.5FS1025———————1409075655545
0.5FS1030———————16010585706550
5P10/10P102.51351008575554540353030303030
5P10/10P105235170135120857055504540403535
5P10/10P1010———235210145110958080605045
5P10/10P1015—————20515513011090808560
5P10/10P1020—————2652001651401151009580
5P10/10P1025——————24520017014012011580
5P10/10P1030———————235200185140130110
5P15/10P152.517013511595756050404040353535
5P15/10P155220185145115907570605555454545
5P15/10P1510————27020016013011595857060
5P15/10P1515—————2201801501351151109080
5P15/10P1520——————230205170145135110100
5P15/10P1525———————255205175160130115
5P15/10P1530————————240205190155130
5P20/10P202.5220175145125907585605050504540
5P20/10P205——23520014511590757065555045
5P20/10P2010————2552001651501251101058575
5P20/10P2015———————235215175150140115
5P20/10P2020————————225195175145125
5P20/10P2025—————————235215175150
5P20/10P2030——————————250205175
5P30/10P302.5——250205175130105908575706555
5P30/10P305———265210165145135115110958075
5P30/10P3010——————255235195170155125115
5P30/10P3015————————265245215170155
5P30/10P3020—————————275215195—
5P30/10P3025——————————270235—
5P30/10P3030———————————275—
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS1455 — click image to zoom / view original.

Product Overview

About This Product

CGIS1455

This current transformer is built for inflatable switchgear at 35 kV, measuring primary current for protection and metering in compact ring-main and medium-voltage cubicles. Its dry epoxy resin insulation and stackable coil construction let the height grow with the number of cores, so the unit occupies minimal panel space in dense switchrooms.

Accuracy classes 0.2FS10/0.5FS10 and 0.5FS10 are available with rated outputs from 2.5 VA to 30 VA; for example, 0.2FS10/0.5FS10 at 5 VA is rated 130 A at 125 A primary and 30 A at 600 A primary. Within the family, choose the 0.2FS10/0.5FS10 rows where dual-class metering and protection are needed, and 0.5FS10 rows for metering alone. Compliance follows IEC 61869; test certificates and routine reports are available [On Request].

Typical deployment is in medium-voltage switchgear, ring-main units and centre-mounted cubicles. Earth the secondary at one point and bond it to the cubicle earth; never open-circuit the secondary while energized. DC or non-standard frequencies are not applicable. Ratios, secondary lead length and documentation packages are customized; quote and lead time follow inquiry.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs