CGIS1590 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for CGIS, 35kV system, dry insulation, suitable for metering and protection in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS1590 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
connect primary through the inner diameter; secondary terminals are 1S1/1S2 for main winding, and 2S1/2S2 for protection winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: The primary voltage is 35kV.
Q: What are the dimensions?
A: Outer diameter is Φ149mm, inner diameter is Φ90mm.
Q: What is the insulation type?
A: Dry epoxy resin insulation.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | (50) h | (50) h | (60) h | (75) h | (100) h | (125) h | (150) h | (200) h | (250) h | (300) h | (400) h | (500) h | (600) h | (750) h | (1000) h | (1200) h |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2FS10 / 0.5FS10 | 2.5 | — | — | — | 120 | 80 | 55 | 40 | 35 | 35 | 30 | 30 | 30 | 35 | 30 | 30 | — |
| 0.2FS10 / 0.5FS10 | 5 | — | — | — | 120 | 85 | 60 | 50 | 45 | 35 | 35 | 45 | 30 | 30 | — | — | — |
| 0.2FS10 / 0.5FS10 | 10 | — | — | — | — | — | 95 | 75 | 65 | 50 | 45 | 50 | 65 | 35 | 30 | — | — |
| 0.2FS10 / 0.5FS10 | 15 | — | — | — | — | — | — | 105 | 80 | 70 | 60 | 65 | 85 | 40 | 35 | — | — |
| 0.2FS10 / 0.5FS10 | 20 | — | — | — | — | — | — | — | — | 70 | 75 | 95 | 40 | 35 | — | — | — |
| 0.2FS10 / 0.5FS10 | 25 | — | — | — | — | — | — | — | — | — | — | — | 45 | 40 | — | — | — |
| 0.2FS10 / 0.5FS10 | 30 | — | — | — | — | — | — | — | — | — | — | — | — | 45 | 40 | — | — |
| 0.5 | 2.5 | — | — | 80 | 65 | 60 | 45 | 40 | 35 | 35 | 30 | 30 | 30 | 30 | 30 | 25 | — |
| 0.5 | 5 | — | — | 120 | 100 | 80 | 70 | 60 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 25 | — |
| 0.5 | 10 | — | — | — | 130 | 115 | 90 | 70 | 65 | 50 | 35 | 30 | 30 | 30 | 30 | 25 | — |
| 0.5 | 15 | — | — | — | — | — | — | 100 | 80 | 65 | 40 | 35 | 35 | 30 | 30 | 25 | — |
| 0.5 | 20 | — | — | — | — | — | — | — | — | — | 45 | 35 | 35 | 30 | 25 | — | — |
| 0.5 | 25 | — | — | — | — | — | — | — | — | — | — | 45 | 40 | 40 | 35 | 30 | — |
| 0.5 | 30 | — | — | — | — | — | — | — | — | — | — | — | 45 | 40 | 40 | 35 | 30 |
| 5P10 / 10P10 | 2.5 | 150 | 140 | 120 | 90 | 75 | 65 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 40 | — |
| 5P10 / 10P10 | 5 | — | — | — | 140 | 115 | 100 | 80 | 65 | 55 | 50 | 40 | 40 | 35 | 45 | 45 | — |
| 5P10 / 10P10 | 10 | — | — | — | — | — | 130 | 105 | 90 | 75 | 60 | 60 | 50 | 50 | 65 | 60 | — |
| 5P10 / 10P10 | 15 | — | — | — | — | — | — | — | 125 | 100 | 85 | 80 | 65 | 80 | 75 | — | — |
| 5P10 / 10P10 | 20 | — | — | — | — | — | — | — | — | 125 | 100 | 85 | 80 | 85 | 90 | — | — |
| 5P10 / 10P10 | 25 | — | — | — | — | — | — | — | — | — | 125 | 115 | 95 | 115 | 110 | — | — |
| 5P10 / 10P10 | 30 | — | — | — | — | — | — | — | — | — | — | 110 | 135 | 125 | — | — | — |
| 5P20 / 10P20 | 2.5 | — | — | 145 | 135 | 110 | 90 | 80 | 65 | 55 | 55 | 55 | 90 | 85 | — | — | — |
| 5P20 / 10P20 | 5 | — | — | — | — | 140 | 120 | 95 | 80 | 80 | 75 | 115 | 110 | — | — | — | — |
| 5P20 / 10P20 | 10 | — | — | — | — | — | — | 145 | 125 | 125 | 115 | — | — | — | — | — | — |
| 5P30 / 10P30 | 2.5 | — | — | — | — | 145 | 130 | 110 | 100 | 100 | 100 | 100 | — | — | — | — | — |
| 5P30 / 10P30 | 5 | — | — | — | — | — | — | 145 | 145 | 145 | 145 | — | — | — | — | — | — |
Dimension & outline drawing of CGIS1590 — click image to zoom / view original.
The CGIS1590 is an indoor dry epoxy resin cast current transformer for 35 kV CGIS gas insulated switchgear, stepping primary current down to a metering or protection secondary. Its annular cast body measures Φ149 mm outer and Φ90 mm inner, and the epoxy insulation is applied to the winding assembly for indoor service at 50/60 Hz.
Accuracy classes cover 0.2FS10, 0.5FS10, 0.5, 5P10, 10P10 and 5P20, with rated outputs from 2.5 VA to 30 VA; for example, the 0.5 class at 10 VA holds its accuracy to a rated continuous thermal current of 130 times rated current, and the 0.2FS10/0.5FS10 rows extend to 120 times at 2.5 VA. Insulation level, short-time thermal current and weight are stated on the nameplate and in the official datasheet [On Request].
This unit is intended for metering and protection inside CGIS switchgear, not for outdoor or open-air installation. Earth the secondary at one point and never open-circuit it while the primary is energized. Custom ratios and accuracy classes, calibration certificates and test reports are available on request, with lead time confirmed at quotation.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.