KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS1590
CGIS1590 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kVCGIS1590
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS1590

CGIS1590 Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1590 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • Indoor epoxy resin casting current transformer for CGIS
  • outer diameter Φ149mm
  • inner diameter Φ90mm
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS1590

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy resin CT for CGIS, 35kV system, dry insulation, suitable for metering and protection in gas-insulated switchgear.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS1590Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 35kV gas-insulated switchgear (CGIS) applications
  • Indoor installations with dry epoxy resin insulation
  • Current measurement for metering and protection
  • 50/60Hz power systems

Not Recommended For

  • Outdoor installations without additional protection
  • Voltage transformation (not a PT)
  • Systems above 35kV
  • Oil or SF6 insulated CT applications

Topology & Wiring

connect primary through the inner diameter; secondary terminals are 1S1/1S2 for main winding, and 2S1/2S2 for protection winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only. Follow IEC 61869-2 terminal markings.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: The primary voltage is 35kV.

Q: What are the dimensions?

A: Outer diameter is Φ149mm, inner diameter is Φ90mm.

Q: What is the insulation type?

A: Dry epoxy resin insulation.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS1590
18 cols · 26 rows

CGIS1590 Current Transformer for Gas-Insulated Switchgear — Technical Data

Accuracy classRated output (VA)(50) h(50) h(60) h(75) h(100) h(125) h(150) h(200) h(250) h(300) h(400) h(500) h(600) h(750) h(1000) h(1200) h
0.2FS10 / 0.5FS102.5———1208055403535303030353030—
0.2FS10 / 0.5FS105———120856050453535453030———
0.2FS10 / 0.5FS1010—————957565504550653530——
0.2FS10 / 0.5FS1015——————10580706065854035——
0.2FS10 / 0.5FS1020————————7075954035———
0.2FS10 / 0.5FS1025———————————4540———
0.2FS10 / 0.5FS1030————————————4540——
0.52.5——80656045403535303030303025—
0.55——1201008070604540353030303025—
0.510———13011590706550353030303025—
0.515——————1008065403535303025—
0.520—————————4535353025——
0.525——————————4540403530—
0.530———————————4540403530
5P10 / 10P102.5150140120907565554540353030303040—
5P10 / 10P105———140115100806555504040354545—
5P10 / 10P1010—————1301059075606050506560—
5P10 / 10P1015———————1251008580658075——
5P10 / 10P1020————————12510085808590——
5P10 / 10P1025—————————12511595115110——
5P10 / 10P1030——————————110135125———
5P20 / 10P202.5——1451351109080655555559085———
5P20 / 10P205————14012095808075115110————
5P20 / 10P2010——————145125125115——————
5P30 / 10P302.5————145130110100100100100—————
5P30 / 10P305——————145145145145——————
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS1590 — click image to zoom / view original.

Product Overview

About This Product

CGIS1590

The CGIS1590 is an indoor dry epoxy resin cast current transformer for 35 kV CGIS gas insulated switchgear, stepping primary current down to a metering or protection secondary. Its annular cast body measures Φ149 mm outer and Φ90 mm inner, and the epoxy insulation is applied to the winding assembly for indoor service at 50/60 Hz.

Accuracy classes cover 0.2FS10, 0.5FS10, 0.5, 5P10, 10P10 and 5P20, with rated outputs from 2.5 VA to 30 VA; for example, the 0.5 class at 10 VA holds its accuracy to a rated continuous thermal current of 130 times rated current, and the 0.2FS10/0.5FS10 rows extend to 120 times at 2.5 VA. Insulation level, short-time thermal current and weight are stated on the nameplate and in the official datasheet [On Request].

This unit is intended for metering and protection inside CGIS switchgear, not for outdoor or open-air installation. Earth the secondary at one point and never open-circuit it while the primary is energized. Custom ratios and accuracy classes, calibration certificates and test reports are available on request, with lead time confirmed at quotation.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS2010

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-II

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs