CGIS1760 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
CGIS1760 is a 35kV indoor epoxy resin current transformer for CGIS gas insulated switchgear, offering multiple accuracy and burden options.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS1760 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the window. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation type?
A: Dry epoxy resin.
Q: What is the primary voltage rating?
A: 35kV.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor CGIS applications.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2S FS10 / 0.2 FS10 / 0.5 FS10 | 2.5 | — | — | — | — | 85 | 60 | 50 | 35 | 30 | 30 | 30 | 30 | 30 | 35 | 35 | 35 |
| 5 | — | — | — | — | 130 | 90 | 70 | 50 | 40 | 35 | 30 | 30 | 30 | 35 | 35 | 35 | |
| 10 | — | — | — | — | — | 150 | 115 | 75 | 55 | 45 | 35 | 30 | 35 | 35 | 35 | 35 | |
| 15 | — | — | — | — | — | — | 160 | 100 | 70 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | |
| 0.5FS10 | 2.5 | — | — | 115 | 80 | 50 | 40 | 35 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | — |
| 5 | — | — | 120 | 75 | 60 | 45 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | — | |
| 10 | — | — | — | 120 | 90 | 70 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | — | |
| 15 | — | — | — | — | 120 | 90 | 65 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | — | |
| 5P10 / 10P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 25 | 25 | 25 |
| 5 | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 40 | 35 | 35 | 30 | 30 | 30 | — | |
| 10 | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 60 | 50 | 45 | 45 | 35 | 35 | 35 | — | |
| 15 | — | — | — | 155 | 130 | 110 | 90 | 80 | 80 | 65 | 60 | 50 | 45 | 45 | 45 | — | |
| 5P20 / 10P20 | 2.5 | — | 145 | 125 | 90 | 75 | 65 | 60 | 50 | 50 | 50 | 40 | 40 | 35 | 35 | 35 | 35 |
| 5 | — | — | 145 | 115 | 95 | 90 | 75 | 70 | 65 | 55 | 50 | 50 | 45 | 45 | 45 | — | |
| 10 | — | — | — | — | 150 | 125 | 110 | 105 | 85 | 75 | 70 | 60 | 60 | 60 | 60 | 60 | |
| 15 | — | — | — | — | — | — | 150 | 140 | 115 | 100 | 90 | 75 | 75 | 75 | 75 | 75 |
Dimension & outline drawing of CGIS1760 — click image to zoom / view original.
The CGIS1760 is an indoor epoxy resin casting current transformer for 35kV gas insulated switchgear, addressing the engineering pain of CT saturation and light-load metering error in compact cubicles through its 0.2S FS10 and 0.5 FS10 accuracy classes. Its square housing with a 102.5mm inner window is built around dry epoxy resin casting, with routine factory checks covering ratio and polarity verification, power-frequency withstand and partial-discharge screening on each unit.
Rated output extends to 85 VA at 0.2S FS10 and 130 VA at 5 VA class, with 5P10 and 10P10 protection cores available for short-time thermal and dynamic stability duties; exact short-time ratings are stated on the nameplate. Within the CGIS family, the 0.2S class suits revenue metering where light-load accuracy matters, while 5P10 or 10P10 cores are selected for protection circuits. Type-test and routine-test reports are available [On Request].
Typical deployment is inside medium-voltage switchgear and ring-main units, not outdoor open-air installation. Earth the secondary at one point and never open-circuit it while energized; verify ratio and polarity before commissioning. OEM and private-label variants, customized ratios and accuracy classes, and document packages are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS2010 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 II Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-II) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.