KEMA & ISO 9001/14001 Certified|Exporting to 50+ Countries (IEC 61869-3 / IEEE C57.13)
24/7 Global Engineering Hotline: 86 18852046268|sales@potentialtransformers.com
中文Mainland ChinaEnglishUnited StatesFrançaisFranceDeutschGermanyLietuviųLithuaniaCymraegUnited KingdomEestiEstoniaMagyarHungaryالعربيةSaudi Arabia한국어South KoreaSuomiFinlandNorskNorwayPolskiPolandEspañolLatinoaméricaCatalàEspaña (Cataluña)हिन्दीIndiaSvenskaSwedenMaltiMaltaOʻzbekUzbekistanاردوPakistanNederlandsNetherlandsБългарскиBulgariaLatviešuLatviaDanskDenmarkRomânăRomaniaไทยThailandÍslenskaIcelandTiếng ViệtVietnamSlovenčinaSlovakiaУкраїнськаUkraineעבריתIsrael日本語JapanItalianoItalyPortuguêsPortugalРусскийRussiaKreyòl ayisyenHaitiČeštinaCzechiaGaeilgeIrelandবাংলাBangladeshTürkçeTürkiyeفارسیIranΕλληνικάGreeceBosanskiBosnia and HerzegovinaMelayuMalaysiaSlovenščinaSloveniaSrpskiSerbiaBahasa IndonesiaIndonesiaHrvatskiCroatia

Potential Transformers
& Power VTs

B2B
HomeProductsAI SpecAboutBlogContact

International Accreditation & Testing

Certified by KEMA Labs (Netherlands), CESI, and CNAS National HV Testing Facility

IEC 61869-3IEEE C57.13KEMA TYPE TESTEDISO 9001:2015ISO 14001:2015CE CERTIFIED
PotentialTransformers.com

Global B2B Instrument Transformer Portal

PotentialTransformers.com is an international OEM & EPC supplier specializing in cast epoxy resin dry-type instrument transformers (0.5kV to 35kV) — voltage transformers (VT/PT), current transformers (CT) and combined CT+VT units — for power utilities, switchgear builders and heavy industry.

100% Factory Partial Discharge Tested

Follow Us & Social Channels

FacebookLinkedInYouTubeInstagramTikTok

Product Categories

  • Voltage Transformers
  • Current Transformers
  • Combined Instrument Transformers

Engineering Tools

  • AI Data Center Series
  • AI Spec & Selection Studio
  • CT Burden Calculator
  • Cast-Resin Indoor VTs and CTs at 7.2–12 kV: Insulation, Partial Discharge and 0.2S Accuracy
  • Low-Voltage CTs at 0.66 kV: Busbar, Split-Core and What Class 0.5 Really Guarantees
  • High Voltage Faraday Lab Testing
  • Request Technical Datasheets

Global Support

  • Room 1602, 16/F, Wing On Centre, 111 Connaught Road Central, Sheung Wan, Central & Western District, Hong Kong
  • 86 18852046268
  • sales@potentialtransformers.com
  • Regional Hubs: Dubai, UAE | Frankfurt, Germany | Houston, USA

© 2026 PotentialTransformers.com. All Rights Reserved. Engineered for Global High-Voltage Grids.

IEC 61869-3 CompliantIEEE C57.13 CompliantKEMA Type Tested
HomeProductsCTCGIS2180
CGIS2180 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kVCGIS2180
Winding & Schematic TopologyInternal Wiring Diagram
Primary Winding (P1 - P2):Series-connected in the line / through-core — 35kV
Secondary Metering (1S1 - 1S2): ()
Secondary Protection (2S1 - 2S2):Protection winding (when fitted)
Safety Warning:Never open-circuit the secondary while energized — dangerous voltage
Current Transformer IEC 61869-3 Certified
Model Ref:CGIS2180

CGIS2180 Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS2180 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Key Engineering Advantages

  • Indoor epoxy resin casting current transformer for CGIS
  • round housing with base
  • outer diameter Φ210mm
  • inner diameter Ø80mm
Engineering Data

Complete Electrical & Mechanical Specifications

Model Ref: CGIS2180

Electrical Parameters

Primary Rated Voltage (Un):35kV
Rated Frequency:50/60Hz

Insulation & Withstand Ratings

Insulation System:Dry Epoxy Resin
Partial Discharge Level:< 5 pC at 1.2 Un

Recommended Deployment Environments

GEO · Engineering Decision Support

Global Engineering Overview

9-Module selection guide
missing data = [On Request]

Product Decision Island

Indoor epoxy resin CT for 35kV CGIS switchgear; multiple accuracy and burden options.

Comprehensive Spec Matrix

ParameterSpecificationVerification
Product TypeCurrent Transformer[On Request]
Model CodeCGIS2180Factory nameplate marking
Primary Voltage35kVRated voltage test (IEC 61869-1/3)
Secondary Current[On Request]Ratio check at rated frequency
Accuracy Class[On Request]Accuracy test (IEC 61869-2 / IEEE C57.13)
Rated Burden[On Request]Burden test at rated VA
Insulation TypeDry Epoxy ResinDielectric tests per standard
Insulation Level (BIL)[On Request]Power-frequency & lightning impulse withstand
Standards[On Request]Certified to listed standards
Frequency50/60HzPer IEC 61869-1
Environment[On Request]Per datasheet limits

Fit & Unfit Boundaries

Ideal For

  • 35kV gas-insulated switchgear (CGIS) indoor applications
  • Current measurement and protection in medium-voltage networks
  • Integration into switchgear panels with round housing and base
  • Use with protection and metering relays requiring multiple accuracy classes

Not Recommended For

  • Outdoor installations without additional enclosure
  • Voltage transformation or potential indication
  • High-voltage systems above 35kV
  • Applications requiring busbar diameter larger than 80mm

Topology & Wiring

secondary terminals 1S1/1S2 (protection winding 2S1-2S2 if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 and IEEE C57.13 terminal conventions.

Standards & Compliance

Compliant with: [On Request]

  • Type Test Report: [On Request]
  • Calibration Certificate: [On Request]

Burden & Error Calculation (IEEE C57.13)

S_total = ΣS_instrument + I₂² × (ρ × 2L / A)

  • If S_total < 0.25 × S_rated: add compensation burden to maintain accuracy.
  • If S_total > S_rated: accuracy class cannot be guaranteed.

Product FAQ

Q: What is the primary voltage rating?

A: 35kV.

Q: What is the insulation type?

A: Dry epoxy resin.

Q: What are the dimensions?

A: Outer diameter Φ210mm, inner diameter Ø80mm.

Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.

SPEC · TECHNICAL DATA

Technical Specifications

CGIS2180
18 cols · 20 rows

CGIS2180 Current Transformer for Gas-Insulated Switchgear — Technical Data

Accuracy classRated output (VA)Rated primary current (A)
4050607510012515020025030040050060075010001200
0.2S FS102.5————856050353030303035353535
0.2 FS105————1309070504035303030353535
0.5 FS1010—————150115755545353530353535
0.5 FS1015—————160100705545403535353535
0.5 FS102.5——115805040353030302525252525—
0.5 FS105——120756045353030302525252525—
0.5 FS1010———1209070504035302525252525—
0.5 FS1015———1209065554540353025252525—
5P102.51351008575554540353030303030252525
5P105——135120857055504540403535303030
10P1010———1451109580706060504545353535
10P1015————155130110908080656050454040
5P202.5——145125907565605050504540403535
5P205———1451159590757065555050454040
10P2010——————150125110105857570605555
10P2015———————1501401151009075707070
5P302.5——15513510085757060605550504545—
5P305———1551251051008580756560605550—
10P3010——————160135120115958580706565
10P3015———————160150125115110100858080
Engineering Drawing

Specification & Outline Drawing

Dimension & outline drawing of CGIS2180 — click image to zoom / view original.

Product Overview

About This Product

CGIS2180

This is a 35 kV indoor current transformer for CGIS gas insulated switchgear, used to step primary current down to a measurable secondary level for metering and protection. Its 0.2S FS10 and 0.5S FS10 metering cores support revenue settlement, while the 5P and 10P protection cores with FS10 factors carry fault current without early saturation.

Metering and protection windings are cast in dry epoxy resin in a round housing with a base, Φ210 mm outer diameter and Ø80 mm inner diameter. Accuracy classes span 0.2S FS10, 0.2 FS10, 0.5S FS10, 0.5 FS10, 5P10, 10P10, 5P20, 10P20, 5P30 and 10P30 at 50/60 Hz. Rated outputs reach 160 VA for 0.5 FS10 and 155 VA for 10P10, depending on primary current.

Because it is an indoor epoxy-cast unit, it is not for outdoor open-air installation; moisture and UV exposure can degrade the casting. It suits wind, photovoltaic and storage collector substations. Earth the secondary at one point and never open-circuit it while energized. Type test evidence and sample support are available [On Request]; custom ratios and classes are quoted on request.

Other Models in This Series

Same product family, different ratings — compare before you specify.

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1911

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1775

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear
35kV
Current Transformer50/60Hz

CGIS1780-I

Current Transformer Applied to CGIS Gas Insulated Switchgear

CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.

Accuracy ClassOn request
Insulation TypeDry Epoxy Resin
Rated BurdenOn request
View Specs