CGIS2313 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin cast CT for CGIS, 35kV system, 50/60Hz. Suitable for protection and metering in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2313 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through window (Ø130mm). Secondary terminals: 1S1/1S2 for main winding, 2S1-2S2 for protection winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 terminal markings.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: The primary voltage is 35kV.
Q: What is the insulation type?
A: Dry epoxy resin casting.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor CGIS applications.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2S FS10 | 2.5 | — | — | — | 85 | 60 | 50 | 35 | 30 | 30 | 30 | 30 | 30 | 35 | 35 | 35 | — |
| 0.2 FS10 | 5 | — | — | — | 130 | 90 | 70 | 50 | 40 | 35 | 30 | 30 | 30 | 35 | 35 | 35 | — |
| 0.5S FS10 | 10 | — | — | — | — | 150 | 115 | 75 | 55 | 45 | 35 | 35 | 30 | 35 | 35 | 35 | — |
| 0.5S FS10 | 15 | — | — | — | — | — | 160 | 100 | 70 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | — |
| 0.5 FS10 | 2.5 | — | — | 115 | 80 | 50 | 40 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | 25 | — |
| 0.5 FS10 | 5 | — | — | — | 120 | 75 | 60 | 45 | 35 | 30 | 30 | 30 | 25 | 25 | 25 | 25 | — |
| 0.5 FS10 | 10 | — | — | — | — | 120 | 90 | 70 | 50 | 40 | 35 | 35 | 30 | 25 | 25 | 25 | — |
| 0.5 FS10 | 15 | — | — | — | — | — | 120 | 90 | 65 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 |
| 5P10 / 10P10 | 2.5 | 135 | 100 | 85 | 75 | 55 | 45 | 40 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 25 | 25 |
| 5P10 / 10P10 | 5 | — | — | — | 135 | 120 | 85 | 70 | 55 | 50 | 45 | 40 | 35 | 35 | 35 | 30 | 30 |
| 5P10 / 10P10 | 10 | — | — | — | — | 145 | 110 | 95 | 80 | 70 | 60 | 60 | 50 | 45 | 45 | 35 | 35 |
| 5P10 / 10P10 | 15 | — | — | — | — | — | 155 | 130 | 110 | 90 | 80 | 80 | 65 | 60 | 50 | 45 | 40 |
| 5P20 / 10P20 | 2.5 | 145 | 110 | 95 | 85 | 65 | 55 | 50 | 45 | 40 | 40 | 40 | 40 | 40 | 40 | 35 | 35 |
| 5P20 / 10P20 | 5 | — | — | — | 145 | 130 | 95 | 80 | 65 | 60 | 55 | 50 | 50 | 45 | 45 | 40 | 40 |
| 5P20 / 10P20 | 10 | — | — | — | — | 155 | 120 | 105 | 90 | 80 | 70 | 70 | 60 | 55 | 55 | 45 | 45 |
| 5P20 / 10P20 | 15 | — | — | — | — | — | 165 | 140 | 120 | 100 | 90 | 90 | 75 | 70 | 60 | 55 | 50 |
Dimension & outline drawing of CGIS2313 — click image to zoom / view original.
This is a 35 kV indoor current transformer built on a dry epoxy resin insulation system, designed for installation in CGIS gas insulated switchgear to measure primary current and supply protective relays and metering instruments. The chamfered square housing with its Ø130 mm inner window keeps the cast body compact, so it occupies little space in the switchgear compartment and simplifies arrangement inside the switchgear room.
Accuracy classes cover 0.2S FS10, 0.2 FS10, 0.5S FS10, 0.5 FS10, 5P10, 10P10, 5P30 and 10P30 at 50/60 Hz, with rated outputs in VA matched to each class as listed in the parameter table. The secondary circuit must never be open-circuited while the primary is energized. As an indoor unit it suits wind, photovoltaic and storage collector substations, where the secondary wiring is checked by insulation resistance, polarity and ratio verification before energization.
It is not intended for DC or non-standard frequencies. [On Request] covers customized ratios, accuracy classes, type test reports and delivery schedules.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.