CGIS2513 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Epoxy resin CT for 35kV CGIS, suitable for indoor GIS metering and protection.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2513 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the bushing. Secondary terminals: 1S1/1S2 for main winding, 2S1/2S2 for protection winding if present. Never open-circuit the secondary of a CT while energized – hazardous voltage. Ground the secondary circuit at one point per IEC 61869-2.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The primary voltage is 35kV; insulation level details are [On Request].
Q: Can this CT be used outdoors?
A: No, it is designed for indoor CGIS applications.
Q: What are the available accuracy classes?
A: Accuracy classes are [On Request] as per specification.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | Rated primary current (A) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 100 | 150 | 200 | 250 | 300 | 400 | 600 | 800 | 1000 | |||||||||||
| h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | ||
| 0.2S/5P10 | 2.5 | — | — | 40 | — | 30 | — | 30 | — | 30 | — | 25 | — | 25 | — | 25 | — | 25 | — |
| 0.2S/5P10 | 5 | — | — | 55 | — | 40 | — | 35 | — | 35 | — | 30 | — | 25 | — | 25 | — | 25 | — |
| 0.2S/5P10 | 7.5 | — | — | 70 | — | 50 | — | 40 | — | 35 | — | 35 | — | 30 | — | 25 | — | 25 | — |
| 0.2S/5P10 | 10 | — | — | 85 | — | 60 | — | 50 | — | 40 | — | 35 | — | 35 | — | 25 | — | 25 | — |
| 0.2S/5P10 | 15 | — | — | 115 | — | 80 | — | 65 | — | 50 | — | 45 | — | 40 | — | 30 | — | 30 | — |
| 0.2S/5P10 | 20 | — | — | 145 | — | 95 | — | 80 | — | 60 | — | 50 | — | 45 | — | 35 | — | 30 | — |
| 0.2S/5P10 | 25 | — | — | 165 | — | 115 | — | 95 | — | 70 | — | 55 | — | 50 | — | 35 | — | 35 | — |
| 0.2S/5P10 | 30 | — | — | 185 | — | 135 | — | 105 | — | 80 | — | 65 | — | 55 | — | 40 | — | 40 | — |
| 0.5/5P10 | 2.5 | 71 | — | 40 | — | 30 | — | 25 | — | 25 | — | 20 | — | 20 | — | 20 | — | 20 | — |
| 0.5/5P10 | 5 | 105 | — | 55 | — | 40 | — | 35 | — | 30 | — | 25 | — | 20 | — | 20 | — | 20 | — |
| 0.5/5P10 | 7.5 | 135 | — | 70 | — | 50 | — | 40 | — | 35 | — | 30 | — | 20 | — | 20 | — | 20 | — |
| 0.5/5P10 | 10 | 180 | — | 85 | — | 65 | — | 50 | — | 40 | — | 30 | — | 25 | — | 20 | — | 20 | — |
| 0.5/5P10 | 15 | — | — | 115 | — | 85 | — | 60 | — | 50 | — | 35 | — | 30 | — | 25 | — | 20 | — |
| 0.5/5P10 | 20 | — | — | 145 | — | 115 | — | 75 | — | 55 | — | 45 | — | 35 | — | 25 | — | 25 | — |
| 0.5/5P10 | 25 | — | — | 165 | — | 135 | — | 85 | — | 65 | — | 55 | — | 40 | — | 30 | — | 25 | — |
| 0.5/5P10 | 30 | — | — | 185 | — | 155 | — | 95 | — | 75 | — | 60 | — | 45 | — | 30 | — | 25 | — |
| 5P10 / 10P10 | 2.5 | 40 | — | 30 | — | 25 | — | 25 | — | 20 | — | 20 | — | 20 | — | 20 | — | 20 | — |
| 5P10 / 10P10 | 5 | 60 | — | 45 | — | 35 | — | 35 | — | 30 | — | 25 | — | 25 | — | 20 | — | 20 | — |
| 5P10 / 10P10 | 7.5 | 80 | — | 60 | — | 50 | — | 40 | — | 35 | — | 30 | — | 25 | — | 25 | — | 20 | — |
| 5P10 / 10P10 | 10 | 100 | — | 70 | — | 60 | — | 50 | — | 45 | — | 35 | — | 30 | — | 30 | — | 25 | — |
| 5P10 / 10P10 | 15 | 140 | — | 100 | — | 80 | — | 70 | — | 55 | — | 45 | — | 40 | — | 35 | — | 30 | — |
| 5P10 / 10P10 | 20 | 180 | — | 130 | — | 100 | — | 80 | — | 70 | — | 60 | — | 50 | — | 45 | — | 35 | — |
| 5P10 / 10P10 | 25 | — | — | 155 | — | 120 | — | 100 | — | 80 | — | 70 | — | 60 | — | 50 | — | 45 | — |
| 5P10 / 10P10 | 30 | — | — | 180 | — | 140 | — | 115 | — | 100 | — | 80 | — | 70 | — | 60 | — | 50 | — |
| 5P20 / 10P20 | 2.5 | 70 | — | 50 | — | 40 | — | 35 | — | 30 | — | 30 | — | 30 | — | 25 | — | 25 | — |
| 5P20 / 10P20 | 5 | 110 | — | 80 | — | 65 | — | 55 | — | 50 | — | 40 | — | 35 | — | 35 | — | 30 | — |
| 5P20 / 10P20 | 7.5 | 150 | — | 105 | — | 80 | — | 70 | — | 60 | — | 50 | — | 40 | — | 40 | — | 35 | — |
| 5P20 / 10P20 | 10 | — | — | 135 | — | 100 | — | 90 | — | 75 | — | 65 | — | 60 | — | 50 | — | 45 | — |
| 5P20 / 10P20 | 15 | — | — | 185 | — | 145 | — | 120 | — | 100 | — | 85 | — | 75 | — | 65 | — | 55 | — |
| 5P20 / 10P20 | 20 | — | — | 185 | — | 185 | — | 130 | — | 110 | — | 90 | — | 80 | — | 70 | — | 60 | — |
| 5P20 / 10P20 | 25 | — | — | — | — | 185 | — | 160 | — | 130 | — | 110 | — | 90 | — | 80 | — | 70 | — |
| 5P20 / 10P20 | 30 | — | — | — | — | — | — | 185 | — | 150 | — | 130 | — | 110 | — | 90 | — | 75 | — |
Dimension & outline drawing of CGIS2513 — click image to zoom / view original.
This is a 35 kV indoor current transformer designed to be installed inside CGIS gas insulated switchgear cubicles, where it measures primary current and provides isolated signals to metering and protection relays. Its round housing with base fits the switchgear compartment envelope, and the outer diameter is Ø130 mm.
The insulation is dry epoxy resin casting, which gives the unit its dielectric strength without oil or gas. Accuracy classes 0.2FS10, 0.5FS10, 5P10 and 10P10 are available at 50/60 Hz. Rated output depends on the primary current and class; for example, the 0.2S/5P10 rows list 2.5 VA up to 30 VA, with 30 VA available at 150 A and 200 A. Insulation level, creepage and weight are [On Request].
Typical deployment is indoor switchgear in wind, photovoltaic and storage collector stations. Before energizing, verify insulation resistance, polarity and ratio during handover tests, and earth the secondary at one point. The secondary must never be open-circuited while energized. This unit is limited to 35 kV indoor service; higher voltages require a different model. Custom ratios and classes, export packing and documentation are available on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.