CGIS2517 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for 35kV CGIS switchgear; ring type with Ø250/Ø168mm.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2517 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
secondary terminals 1S1/1S2 (protection winding 2S1-2S2 if applicable). Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point per IEC 61869-2. Ensure proper shorting before disconnecting burden.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating?
A: 35kV.
Q: What is the insulation type?
A: Dry epoxy resin.
Q: Is it suitable for outdoor use?
A: No, it is designed for indoor CGIS applications.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | (100) | (150) | (200) | (250) | (300) | (400) | (500) | (600) | (800) | (1000) | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | h | l | ||
| 0.2FS5/10 0.2FS10/ 0.5FS10 | 2.5 | — | — | 165 | — | 85 | — | 55 | — | 40 | — | 35 | — | 35 | — | 30 | — | 25 | — | — | — |
| 5 | — | — | 205 | — | 115 | — | 85 | — | 55 | — | 40 | — | 40 | — | 35 | — | 35 | — | — | — | |
| 7.5 | — | — | — | — | 145 | — | 105 | — | 65 | — | 55 | — | 50 | — | 35 | — | 35 | — | — | — | |
| 10 | — | — | — | — | 135 | — | 75 | — | 60 | — | 55 | — | 40 | — | 35 | — | 35 | — | — | — | |
| 15 | — | — | — | — | 205 | — | 185 | — | 105 | — | 80 | — | 70 | — | 50 | — | 40 | — | — | — | |
| 20 | — | — | — | — | — | — | 205 | — | 135 | — | 100 | — | 85 | — | 60 | — | 45 | — | — | — | |
| 25 | — | — | — | — | — | — | — | — | 155 | — | 120 | — | 100 | — | 70 | — | 50 | — | — | — | |
| 30 | — | — | — | — | — | — | — | — | 175 | — | 145 | — | 115 | — | 80 | — | 65 | — | — | — | |
| 0.5FS10 | 2.5 | 145 | — | 65 | — | 55 | — | 45 | — | 45 | — | 35 | — | 20 | — | 20 | — | 20 | — | — | — |
| 5 | — | — | 105 | — | 85 | — | 65 | — | 55 | — | 45 | — | 25 | — | 20 | — | 20 | — | — | — | |
| 7.5 | — | — | 135 | — | 105 | — | 85 | — | 75 | — | 55 | — | 35 | — | 30 | — | 25 | — | — | — | |
| 10 | — | — | — | — | 115 | — | 105 | — | 105 | — | 65 | — | 40 | — | 35 | — | 30 | — | — | — | |
| 15 | — | — | — | — | — | — | 135 | — | 115 | — | 95 | — | 50 | — | 40 | — | 35 | — | — | — | |
| 20 | — | — | — | — | — | — | — | — | 145 | — | 125 | — | 70 | — | 50 | — | 40 | — | — | — | |
| 25 | — | — | — | — | — | — | — | — | — | — | 145 | — | 90 | — | 60 | — | 45 | — | — | — | |
| 30 | — | — | — | — | — | — | — | — | — | — | 165 | — | 100 | — | 70 | — | 50 | — | — | — | |
| 5P10/10P10 | 2.5 | 80 | — | 55 | — | 45 | — | 40 | — | 35 | — | 35 | — | 30 | — | 30 | — | 25 | — | — | — |
| 5 | — | — | 125 | — | 85 | — | 70 | — | 60 | — | 50 | — | 40 | — | 35 | — | 35 | — | — | — | |
| 7.5 | — | — | 170 | — | 120 | — | 90 | — | 80 | — | 65 | — | 50 | — | 45 | — | 40 | — | — | — | |
| 10 | — | — | — | — | 150 | — | 120 | — | 100 | — | 80 | — | 70 | — | 55 | — | 45 | — | — | — | |
| 15 | — | — | — | — | — | — | 170 | — | 140 | — | 110 | — | 95 | — | 80 | — | 70 | — | 55 | — | |
| 20 | — | — | — | — | — | — | — | — | 180 | — | 140 | — | 120 | — | 100 | — | 85 | — | 70 | — | |
| 25 | — | — | — | — | — | — | — | — | — | — | 170 | — | 150 | — | 120 | — | 105 | — | 80 | — | |
| 30 | — | — | — | — | — | — | — | — | — | — | — | — | 170 | — | 140 | — | 120 | — | 95 | — | |
| 5P20/10P20 | 2.5 | 160 | — | 110 | — | 90 | — | 75 | — | 65 | — | 65 | — | 60 | — | 55 | — | 45 | — | — | — |
| 5 | — | — | 180 | — | 140 | — | 115 | — | 95 | — | 100 | — | 70 | — | 60 | — | 55 | — | — | — | |
| 7.5 | — | — | — | — | 190 | — | 155 | — | 130 | — | 130 | — | 105 | — | 90 | — | 75 | — | — | — | |
| 10 | — | — | — | — | — | — | 190 | — | 165 | — | 155 | — | 130 | — | 110 | — | 90 | — | — | — | |
| 15 | — | — | — | — | — | — | — | — | — | — | — | — | 180 | — | 150 | — | 120 | — | 100 | — | |
| 20 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 190 | — | 155 | — | 130 | — | |
| 25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 190 | — | 155 | — | |
| 30 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 180 | — | |
Dimension & outline drawing of CGIS2517 — click image to zoom / view original.
The CGIS2517 is an indoor, 35 kV dry epoxy resin cast current transformer for CGIS gas insulated switchgear, intended for revenue metering and protection. Its accuracy classes include 0.2SFS10, 0.2FS10, 0.5SFS10, 0.5FS10, 5P10 and 10P10, with metering and protection windings configured to serve both functions. The large diameter thin wall ring design has an outer diameter of Ø250mm and an inner diameter of Ø168mm, and the epoxy casting provides the primary insulation. Rated output windows span from 2.5 VA up to 30 VA across the listed accuracy classes, allowing the secondary burden to be matched to the connected meter or relay. Compliance follows the IEC 61869 series; test certificates and routine test reports are available [On Request].
Typical deployment is in indoor infrastructure such as rail transit, data centres, hospitals and water facilities. Primary connections follow the H1/H2 or P1/P2 markings, with the secondary earthed at one point and never open circuited while energised. The unit is not suitable for DC or non-standard frequencies, and the secondary must not be open circuited under load. Ratio and accuracy class customisation, documentation packages and lead times are confirmed at inquiry.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.