CGIS2819 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for CGIS, 35kV, 50/60Hz, ring type Ø275/Ø190mm. Suitable for protection and metering in gas-insulated switchgear.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS2819 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through the ring; secondary terminals are 1S1/1S2 for metering, and 2S1/2S2 for protection if applicable. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869 / IEEE C57.13 terminal conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation type of this CT?
A: Dry epoxy resin casting.
Q: What is the primary voltage rating?
A: 35kV.
Q: What are the dimensions of the ring?
A: Outer diameter Ø275mm, inner diameter Ø190mm.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | Rated primary current (A) - | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 100 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 800 | 1000 | ||
| 0.2FS5/1.0FS5/1.0 | 2.5 | 90 | 55 | 45 | 35 | 30 | h | 25 | 25 | 25 | 25 |
| 0.2FS5/1.0FS5/1.0 | 5 | 140 | 85 | 65 | 50 | 35 | 30 | 25 | 25 | 25 | 25 |
| 0.2FS5/1.0FS5/1.0 | 7.5 | 185 | 110 | 85 | 60 | 45 | 35 | 30 | 25 | 25 | 25 |
| 0.2FS5/1.0FS5/1.0 | 10 | 235 | 135 | 105 | 75 | 60 | 45 | 35 | 30 | 25 | 25 |
| 0.2FS5/1.0FS5/1.0 | 15 | — | 195 | 145 | 95 | 65 | 50 | 40 | 30 | 30 | 30 |
| 0.2FS5/1.0FS5/1.0 | 20 | — | — | 185 | 120 | 80 | 60 | 45 | 35 | 30 | 30 |
| 0.2FS5/1.0FS5/1.0 | 25 | — | — | 215 | 145 | 95 | 70 | 55 | 40 | 35 | 35 |
| 0.2FS5/1.0FS5/1.0 | 30 | — | — | — | 170 | 110 | 80 | 65 | 45 | 40 | 40 |
| 0.5FS10 | 2.5 | 90 | 55 | 40 | 35 | 25 | 25 | 20 | 20 | 20 | 20 |
| 0.5FS10 | 5 | 140 | 85 | 55 | 40 | 35 | 30 | 25 | 20 | 20 | 20 |
| 0.5FS10 | 7.5 | 190 | 115 | 70 | 55 | 40 | 30 | 20 | 20 | 20 | 20 |
| 0.5FS10 | 10 | 235 | 145 | 85 | 65 | 45 | 40 | 35 | 25 | 20 | 20 |
| 0.5FS10 | 15 | — | 210 | 115 | 85 | 55 | 45 | 40 | 30 | 25 | 20 |
| 0.5FS10 | 20 | — | — | 145 | 105 | 70 | 50 | 45 | 35 | 25 | 20 |
| 0.5FS10 | 25 | — | — | 175 | 125 | 80 | 60 | 50 | 40 | 30 | 20 |
| 0.5FS10 | 30 | — | — | 205 | 145 | 95 | 70 | 55 | 50 | 30 | 25 |
| 5P10/10P10 | 2.5 | 45 | 35 | 30 | 25 | 25 | 20 | 20 | 20 | 20 | 20 |
| 5P10/10P10 | 5 | 70 | 50 | 40 | 35 | 30 | 30 | 25 | 25 | 20 | 20 |
| 5P10/10P10 | 7.5 | 95 | 65 | 55 | 45 | 40 | 35 | 30 | 30 | 25 | 25 |
| 5P10/10P10 | 10 | 120 | 80 | 65 | 55 | 50 | 40 | 35 | 30 | 30 | 25 |
| 5P10/10P10 | 15 | 170 | 110 | 90 | 75 | 65 | 50 | 45 | 40 | 35 | 30 |
| 5P10/10P10 | 20 | 220 | 145 | 110 | 90 | 80 | 65 | 55 | 50 | 40 | 35 |
| 5P10/10P10 | 25 | — | 175 | 135 | 110 | 95 | 75 | 65 | 55 | 45 | 40 |
| 5P10/10P10 | 30 | — | 205 | 160 | 130 | 110 | 85 | 70 | 65 | 50 | 45 |
| 5P20/10P20 | 2.5 | 80 | 60 | 50 | 45 | 40 | 30 | 30 | 30 | 25 | 30 |
| 5P20/10P20 | 5 | 130 | 90 | 70 | 60 | 50 | 45 | 40 | 35 | 30 | 35 |
| 5P20/10P20 | 7.5 | 180 | 120 | 95 | 80 | 70 | 55 | 50 | 45 | 40 | 40 |
| 5P20/10P20 | 10 | 230 | 155 | 120 | 100 | 85 | 70 | 65 | 55 | 45 | 45 |
| 5P20/10P20 | 15 | — | 220 | 170 | 135 | 115 | 90 | 75 | 70 | 55 | 55 |
| 5P20/10P20 | 20 | — | — | 220 | 175 | 150 | 115 | 95 | 90 | 70 | 65 |
Dimension & outline drawing of CGIS2819 — click image to zoom / view original.
The CGIS2819 is an indoor epoxy resin cast current transformer for 35kV CGIS gas insulated switchgear, providing metering and protection signals at 50/60Hz. Its accuracy classes, 0.2FS5, 1.0FS5 and 1.0, with rated outputs from 2.5VA to 30VA, support billing-grade measurement and protection duties; the metering and protection windings are configured to serve both functions from one unit.
The extra-large thin-wall ring design, Ø275mm outer and Ø190mm inner diameter, suits cable or busbar passage through the core. The dry epoxy resin casting insulates the windings and gives a compact, maintenance-free indoor unit. For trade-settlement metering, calibration and routine test certificates can be supplied [On Request].
Deployment is indoor: wind and photovoltaic collector stations and storage step-up substations using CGIS switchgear. Mounting space, safety clearances and fixing must follow the switchgear layout; earth the secondary at one point and never open-circuit it while energized. This unit is not for outdoor open-air installation. Ratio and accuracy-class customization, documentation packages and delivery terms are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.