CGIS3411 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A or 1A, accuracy class 0.2FS10/0.5SFS10,0.5,5(10)P10,5(10)P20,5(10)P30. Design: Dry Epoxy Resin, 50/60Hz operation.
Indoor epoxy resin CT for CGIS switchgear, 12kV system, multiple accuracy classes including protection classes.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS3411 | Factory nameplate marking |
| Primary Voltage | 12kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | 0.2FS10/0.5SFS10,0.5,5(10)P10,5(10)P20,5(10)P30 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect primary through bushing. Secondary terminals: 1S1/1S2 for metering, 2S1/2S2 for protection. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. Follow IEC 61869-2 and IEEE C57.13 conventions.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation type?
A: Dry epoxy resin.
Q: What are the available accuracy classes?
A: 0.2FS10/0.5SFS10, 0.5, 5(10)P10, 5(10)P20, 5(10)P30.
Q: What is the primary voltage rating?
A: 12kV.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | Rated primary current (A) | ||||||
|---|---|---|---|---|---|---|---|---|
| 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | ||
| 0.2FS10 | 2.5 | 30 | 30 | 30 | 25 | 25 | 25 | 25 |
| 0.2FS10 | 5 | 35 | 35 | 30 | 30 | 30 | 25 | 25 |
| 0.2FS10 | 7.5 | 45 | 40 | 35 | 35 | 35 | 30 | 25 |
| 0.2FS10 | 10 | 50 | 45 | 40 | 40 | 35 | 30 | 20 |
| 0.2FS10 | 15 | 65 | 55 | 50 | 45 | 40 | 35 | 20 |
| 0.2FS10 | 20 | 80 | 70 | 60 | 55 | 50 | 45 | 30 |
| 0.2FS10 | 25 | 95 | 80 | 70 | 65 | 55 | 50 | 35 |
| 0.2FS10 | 30 | 110 | 95 | 80 | 70 | 60 | 55 | 40 |
| 0.5FS10 | 2.5 | 30 | 30 | 30 | 25 | 25 | 25 | 25 |
| 0.5FS10 | 5 | 35 | 35 | 30 | 20 | 20 | 20 | 20 |
| 0.5FS10 | 7.5 | 45 | 40 | 35 | 25 | 20 | 20 | 20 |
| 0.5FS10 | 10 | 50 | 45 | 40 | 25 | 25 | 20 | 20 |
| 0.5FS10 | 15 | 65 | 55 | 50 | 30 | 30 | 25 | 25 |
| 0.5FS10 | 20 | 80 | 70 | 60 | 35 | 30 | 25 | 25 |
| 0.5FS10 | 25 | 95 | 80 | 70 | 40 | 35 | 30 | 25 |
| 0.5FS10 | 30 | 110 | 95 | 80 | 45 | 40 | 30 | 25 |
| 5P10/10P10 | 2.5 | 30 | 25 | 25 | 30 | 25 | 25 | 30 |
| 5P10/10P10 | 5 | 40 | 35 | 30 | 35 | 35 | 35 | 35 |
| 5P10/10P10 | 7.5 | 50 | 45 | 40 | 45 | 40 | 40 | 40 |
| 5P10/10P10 | 10 | 80 | 55 | 55 | 55 | 45 | 45 | 45 |
| 5P10/10P10 | 15 | 85 | 70 | 60 | 70 | 60 | 60 | 65 |
| 5P10/10P10 | 20 | 105 | 90 | 75 | 85 | 75 | 70 | 65 |
| 5P10/10P10 | 25 | 130 | 105 | 90 | 105 | 90 | 80 | 75 |
| 5P10/10P10 | 30 | 125 | 105 | 125 | 100 | 95 | 85 | 85 |
| 5P20/10P20 | 2.5 | 50 | 45 | 40 | 35 | 30 | 35 | 35 |
| 5P20/10P20 | 5 | 75 | 65 | 55 | 45 | 40 | 45 | 45 |
| 5P20/10P20 | 7.5 | 95 | 80 | 70 | 60 | 50 | 55 | 50 |
| 5P20/10P20 | 10 | 120 | 100 | 85 | 70 | 60 | 65 | 60 |
| 5P20/10P20 | 15 | 140 | 120 | 95 | 80 | 85 | 75 | 75 |
| 5P20/10P20 | 20 | — | — | — | 120 | 100 | 110 | 90 |
| 5P20/10P20 | 25 | — | — | — | 140 | 120 | 120 | 105 |
| 5P20/10P20 | 30 | — | — | — | 140 | 140 | 125 | 125 |
Dimension & outline drawing of CGIS3411 — click image to zoom / view original.
This is an indoor dry epoxy resin cast current transformer for 12 kV gas insulated switchgear, converting primary current to a 5 A or 1 A secondary for metering and protection. The solid cast insulation removes the oil or gas dielectric from the current path, so the unit is a sealed, maintenance-free component inside the CGIS enclosure.
The epoxy body is a large rectangular housing 340 mm wide, sized to carry high primary currents. Accuracy classes cover 0.2FS10/0.5SFS10 metering and 0.5, 5(10)P10, 5(10)P20 and 5(10)P30 protection, at 50/60 Hz. From the parameter table, 0.2FS10 at 5 VA holds 35 VA at 400 A and 500 A, 30 VA at 600 A and 800 A, and 25 VA at 1200 A and 1500 A; higher burdens are listed per row. Standard ratios are stocked; non-standard ratios and classes are built to order.
Datasheets, outline drawings and type test reports are available [On Request]. The secondary must never be open-circuited while energized; earth it at one point and verify secondary burden before energizing. Indoor service only.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.