CGIS3608 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 12kV, secondary voltage 5A or 1A, accuracy class 0.2FS10/0.5SFS10,0.5,5(10)P10,5(10)P20,5(10)P30. Design: Dry Epoxy Resin, 50/60Hz operation.
CGIS3608 is a dry epoxy resin current transformer for 12kV gas-insulated switchgear, offering multiple accuracy classes and a wide current range. Suitable for indoor CGIS applications requiring high precision and protection.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS3608 | Factory nameplate marking |
| Primary Voltage | 12kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | 5A or 1A | Ratio check at rated frequency |
| Accuracy Class | 0.2FS10/0.5SFS10,0.5,5(10)P10,5(10)P20,5(10)P30 | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers, ensure secondary terminals are connected as 1S1 and 1S2 for the main winding; if a second protection winding is present, use 2S1 and 2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary winding at one point to ensure safety. Follow IEC 61869-2 terminal markings and verify polarity for correct operation.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating of the CGIS3608?
A: The primary voltage rating is 12kV.
Q: What accuracy classes are available?
A: Accuracy classes include 0.2FS10, 0.5SFS10, 0.5, and protection classes 5P10, 5P20, 5P30.
Q: Can this CT be used outdoors?
A: No, it is designed for indoor use in CGIS gas-insulated switchgear.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | 75 | 100 | 125 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 750 | 1000 | 1200 | 1500 | 2000 | 2500 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.2FS10 / 0.5FS10 | 2.5 | — | — | — | — | 80 | 55 | 40 | 30 | 30 | 30 | 30 | 30 | 35 | 35 | 35 | 35 |
| 5 | — | — | — | — | 115 | 75 | 55 | 40 | 30 | 30 | 30 | 35 | 35 | 35 | 35 | 35 | |
| 10 | — | — | — | — | 115 | 85 | 50 | 40 | 35 | 30 | 30 | 35 | 35 | 35 | 35 | 35 | |
| 15 | — | — | — | — | 115 | 105 | 65 | 50 | 40 | 35 | 30 | 35 | 35 | 35 | 35 | 35 | |
| 20 | — | — | — | — | 140 | 80 | 60 | 45 | 40 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | |
| 25 | — | — | — | — | 165 | 95 | 70 | 55 | 45 | 40 | 35 | 35 | 35 | 35 | 35 | 35 | |
| 30 | — | — | — | — | — | — | 110 | 80 | 60 | 50 | 40 | 40 | 40 | 40 | 35 | 35 | |
| 0.5FS10 | 2.5 | — | 105 | 75 | 60 | 40 | 35 | 30 | 30 | 30 | 20 | 25 | 25 | 25 | 25 | 25 | 25 |
| 5 | — | 165 | 115 | 90 | 55 | 45 | 35 | 30 | 30 | 20 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 10 | — | — | 155 | 85 | 60 | 50 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 15 | — | — | 115 | 80 | 60 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 20 | — | — | 145 | 100 | 75 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 25 | — | — | — | 120 | 90 | 65 | 55 | 45 | 35 | 30 | 25 | 25 | 25 | 25 | 25 | 25 | |
| 30 | — | — | — | — | 140 | 100 | 70 | 60 | 55 | 40 | 35 | 30 | 25 | 25 | 25 | 25 | |
| 10P10 | 2.5 | 110 | 70 | 60 | 50 | 40 | 35 | 30 | 25 | 25 | 20 | 20 | 20 | 20 | 20 | 25 | 25 |
| 5 | 185 | 110 | 100 | 80 | 55 | 45 | 40 | 35 | 30 | 25 | 25 | 25 | 20 | 20 | 25 | 25 | |
| 10 | — | — | 180 | 140 | 90 | 70 | 80 | 55 | 45 | 40 | 35 | 30 | 25 | 30 | 25 | 30 | |
| 15 | — | — | — | 125 | 100 | 85 | 70 | 60 | 50 | 45 | 40 | 35 | 30 | 35 | 35 | 35 | |
| 20 | — | — | — | 180 | 125 | 105 | 90 | 75 | 60 | 55 | 45 | 40 | 35 | 40 | 35 | 40 | |
| 25 | — | — | — | — | 150 | 125 | 105 | 90 | 75 | 60 | 55 | 45 | 40 | 45 | 40 | 40 | |
| 30 | — | — | — | — | 175 | 145 | 125 | 105 | 85 | 70 | 60 | 55 | 45 | 50 | 45 | 50 | |
| 10P20 | 2.5 | 150 | 115 | 95 | 80 | 60 | 50 | 45 | 35 | 35 | 30 | 30 | 30 | 30 | 35 | 35 | 35 |
| 5 | — | 180 | 150 | 125 | 95 | 75 | 65 | 60 | 50 | 45 | 40 | 40 | 35 | 35 | 40 | 40 | |
| 10 | — | — | — | 160 | 125 | 105 | 85 | 80 | 70 | 60 | 50 | 45 | 40 | 45 | 45 | 45 | |
| 15 | — | — | — | 210 | 175 | 145 | 135 | 110 | 90 | 80 | 70 | 60 | 55 | 60 | 50 | 50 | |
| 20 | — | — | — | — | 185 | 170 | 135 | 115 | 95 | 85 | 75 | 65 | 65 | 65 | 60 | 60 | |
| 25 | — | — | — | — | — | 165 | 140 | 115 | 100 | 85 | 75 | 75 | 65 | 75 | 65 | 65 | |
| 30 | — | — | — | — | — | — | 160 | 135 | 115 | 100 | 85 | 85 | 75 | 85 | 75 | 75 | |
| 10P30 | 2.5 | — | 180 | 135 | 115 | 85 | 70 | 60 | 50 | 45 | 40 | 40 | 40 | 50 | 50 | 45 | 45 |
| 5 | — | — | 185 | 135 | 110 | 95 | 85 | 75 | 65 | 55 | 55 | 50 | 50 | 60 | 55 | 55 | |
| 10 | — | — | — | 180 | 155 | 145 | 120 | 100 | 85 | 80 | 75 | 65 | 65 | 70 | 65 | 65 | |
| 15 | — | — | — | — | — | 170 | 135 | 115 | 105 | 95 | 90 | 80 | 80 | 90 | 80 | 80 | |
| 20 | — | — | — | — | — | — | 175 | 145 | 130 | 120 | 100 | 105 | 90 | 105 | 90 | 90 | |
| 25 | — | — | — | — | — | — | — | 175 | 155 | 140 | 115 | 125 | 105 | 125 | 105 | 105 | |
| 30 | — | — | — | — | — | — | — | — | 180 | 160 | 140 | 140 | 120 | 120 | 120 | 120 |
Dimension & outline drawing of CGIS3608 — click image to zoom / view original.
The CGIS3608 is a 12 kV indoor current transformer built for CGIS gas-insulated switchgear, where it supplies measurement and protection circuits without consuming extra cubicle space. Its extra-large rectangular housing, 360 mm wide, addresses the common problem of fitting a high-ratio CT into a compact switchgear compartment.
The unit uses dry epoxy resin casting for solid insulation, with accuracy classes covering 0.2FS10/0.5SFS10, 0.5 and 5(10)P10 through 5(10)P20 and 5(10)P30. For metering, the 0.2FS10/0.5FS10 row shows 80 VA at 200 A and 30 VA from 400 A to 1000 A; protection cores are available with 5(10)P10, 5(10)P20 and 5(10)P30 classes. Secondary output is 5 A or 1 A at 50/60 Hz.
This CT is intended for indoor installation only. It is not a substitute for a higher-voltage unit, and the secondary must never be open-circuited while energized. Before commissioning, verify insulation resistance, polarity and ratio. [On Request] covers test reports, export packing and after-sales support; ratio and class customization are quoted on request.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.