Specialized current transformer for CGIS inflatable switchgear with multiple accuracy classes and abundant primary current specifications; secondary lead length and stacked product height support customized production.
CGIS5008 is a dry epoxy resin current transformer for 35kV inflatable switchgear, offering multiple accuracy classes and customizable secondary leads. It is suitable for indoor RMU applications where space is constrained.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS5008 | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
Connect secondary terminals 1S1 and 1S2 for the main metering/protection winding; if a second winding exists, use 2S1-2S2. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary circuit at one point only, preferably at the switchgear earth bar. Ensure shorting and grounding facilities are provided before disconnecting the CT from the load.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation type of CGIS5008?
A: It uses dry epoxy resin insulation, suitable for indoor applications.
Q: Can the secondary lead length be customized?
A: Yes, secondary lead parameters are customizable as per requirements.
Q: What is the rated frequency range?
A: It operates at 50/60Hz.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy class | Rated output (VA) | Rated primary current (A) | |||||
|---|---|---|---|---|---|---|---|
| 750 | 1000 | 1200 | 1500 | 2000 | 2500 | ||
| 0.2FS10 | 5 | 30 | 30 | 30 | 30 | 30 | 35 |
| 0.2FS10 | 10 | 30 | 30 | 30 | 30 | 30 | 35 |
| 0.2FS10 | 15 | 30 | 30 | 30 | 30 | 30 | 35 |
| 0.2FS10 | 20 | 35 | 30 | 30 | 30 | 30 | 35 |
| 0.2FS10 | 25 | 40 | 30 | 30 | 30 | 30 | 35 |
| 0.2FS10 | 30 | 40 | 35 | 30 | 30 | 30 | 35 |
| 0.5FS10 | 5 | 30 | 30 | 25 | 25 | 25 | 30 |
| 0.5FS10 | 10 | 30 | 30 | 25 | 25 | 25 | 30 |
| 0.5FS10 | 15 | 30 | 30 | 25 | 25 | 25 | 30 |
| 0.5FS10 | 20 | 30 | 30 | 25 | 25 | 25 | 30 |
| 0.5FS10 | 25 | 30 | 30 | 25 | 25 | 25 | 30 |
| 0.5FS10 | 30 | 35 | 30 | 35 | 25 | 25 | 30 |
| 5P10 | 5 | 30 | 25 | 25 | 25 | 25 | 25 |
| 5P10 | 10 | 30 | 30 | 30 | 30 | 30 | 30 |
| 5P10 | 15 | 40 | 35 | 35 | 30 | 30 | 30 |
| 5P10 | 20 | 50 | 40 | 40 | 35 | 30 | 30 |
| 10P10 | 5 | 25 | 25 | 25 | 25 | 25 | 25 |
| 10P10 | 10 | 40 | 35 | 35 | 35 | 35 | 35 |
| 10P10 | 15 | 55 | 45 | 40 | 35 | 35 | 35 |
| 10P10 | 20 | 80 | 50 | 45 | 40 | 35 | 35 |
| 5P15 | 5 | 25 | 25 | 25 | 25 | 25 | 25 |
| 5P15 | 10 | 45 | 40 | 35 | 35 | 30 | 30 |
| 5P15 | 15 | 55 | 45 | 40 | 35 | 35 | 35 |
| 5P15 | 20 | 65 | 55 | 50 | 45 | 40 | 35 |
| 5P15 | 25 | 75 | 60 | 55 | 45 | 40 | 35 |
| 5P15 | 30 | 85 | 70 | 60 | 55 | 45 | 40 |
| 5P20 | 5 | 40 | 35 | 35 | 30 | 30 | 30 |
| 5P20 | 10 | 55 | 50 | 45 | 35 | 35 | 35 |
| 5P20 | 15 | 65 | 60 | 50 | 40 | 40 | 40 |
| 5P20 | 20 | 80 | 65 | 60 | 45 | 45 | 40 |
| 5P20 | 25 | 95 | 75 | 70 | 50 | 45 | 45 |
| 5P20 | 30 | 105 | 85 | 75 | 65 | 55 | 50 |
| 5P30 | 5 | 50 | 45 | 45 | 40 | 40 | 40 |
| 5P30 | 10 | 75 | 65 | 60 | 55 | 45 | 45 |
| 5P30 | 15 | 95 | 80 | 70 | 65 | 55 | 50 |
| 5P30 | 20 | 115 | 95 | 85 | 75 | 60 | 60 |
| 5P30 | 25 | 140 | 115 | 100 | 85 | 70 | 65 |
| 5P30 | 30 | 180 | 130 | 115 | 95 | 75 | 70 |
Dimension & outline drawing of CGIS5008 — click image to zoom / view original.
The CGIS5008 is a 35 kV dry epoxy resin current transformer for inflatable switchgear, designed to IEC 61869, GB/T 20840 and IEEE C57.13 to step primary current down for metering and protection. Its cast-resin body and stacked-core construction suit the sealed gas compartment, with stacked height adjustable to the number of cores and secondary lead parameters customizable at order.
Accuracy options span 0.2FS10, 0.5SFS10, 0.5FS10 and 5P10 through 10P30, with rated outputs from 5 VA to 30 VA across 750 A to 2500 A primary ratings; for example, 0.2FS10 at 30 VA holds 30 VA from 750 A to 2000 A and 35 VA at 2500 A. This places it between indoor-only and outdoor units: it is intended for the enclosed, controlled environment of inflatable switchgear rather than exposed pole-top service.
Secondary terminals follow the nameplate diagram, with the secondary earthed at one point and never open-circuited while energized; verify ratios and polarity before commissioning. Non-sinusoidal loads need derating per [On Request]. OEM branding and document packages are available, with delivery and pricing confirmed at inquiry.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.