CGIS7515S Current Transformer for Inflatable Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Suitable for 35kV CGIS inflatable switchgear applications requiring three-phase integrated current measurement with customizable secondary leads.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | [On Request] |
| Model Code | CGIS7515S | Factory nameplate marking |
| Primary Voltage | 35kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | [On Request] | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | [On Request] | Per datasheet limits |
Ideal For
Not Recommended For
For current transformers, adhere to IEC 61869-2 terminal markings: primary terminals P1/P2, secondary terminals 1S1/1S2 for the main winding, and 2S1/2S2 for protection winding if present. Never open-circuit the secondary of a CT while energized - hazardous voltage may occur. Ground the secondary circuit at one point only. Ensure secondary terminals are shorted before removing the CT from service.
Compliant with: [On Request]
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the primary voltage rating of this CT?
A: The primary voltage rating is 35kV.
Q: Can this CT be used for outdoor applications?
A: No, it is designed for indoor CGIS inflatable switchgear.
Q: Is the secondary lead length customizable?
A: Yes, secondary lead specifications support customized production.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Accuracy classCombined | Rated primary current (A) | 200 | 300 | 400 | 500 | 600 | 700 | 800 |
|---|---|---|---|---|---|---|---|---|
| 0.2/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 0.2/5P10 | 5 | 60 | 80 | 100 | 120 | 140 | 160 | 180 |
| 0.2/5P10 | 10 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.2/5P10 | 15 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.2/5P10 | 20 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.2/5P10 | 25 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.5/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 0.5/5P10 | 5 | 60 | 80 | 100 | 120 | 140 | 160 | 180 |
| 0.5/5P10 | 10 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.5/5P10 | 15 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.5/5P10 | 20 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 0.5/5P10 | 25 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P10 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 5P10/5P10 | 5 | 60 | 80 | 100 | 120 | 140 | 160 | 180 |
| 5P10/5P10 | 10 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P10 | 15 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P10 | 20 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P10 | 25 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P15 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 5P10/5P15 | 5 | 60 | 80 | 100 | 120 | 140 | 160 | 180 |
| 5P10/5P15 | 10 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P15 | 15 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P15 | 20 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P10/5P15 | 25 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P20/5P20 | 2.5 | 30 | 40 | 50 | 60 | 70 | 80 | 90 |
| 5P20/5P20 | 5 | 60 | 80 | 100 | 120 | 140 | 160 | 180 |
| 5P20/5P20 | 10 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P20/5P20 | 15 | 85 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P20/5P20 | 20 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
| 5P20/5P20 | 25 | 105 | 70 | 85 | 100 | 115 | 130 | 150 |
Dimension & outline drawing of CGIS7515S — click image to zoom / view original.
The CGIS7515S is a 35 kV current transformer for inflatable switchgear, designed to step primary current down to metering and protection levels in accordance with IEC 61869, GB/T 20840 and IEEE C57.13. Its dry epoxy resin insulation and three-phase integrated structure house separate metering and protection windings, so accuracy-class circuits and relay circuits remain independent within one compact unit.
Accuracy-class combinations include 0.2FS10, 0.5FS10, 5P10, 10P10, 5P15 and 10P15 at 50/60 Hz. In the 0.2/5P10 and 0.5/5P10 rows, rated output ranges from 30 VA to 180 VA depending on the rated primary current selected from 200 A to 800 A. Insulation level and weight are stated on the nameplate and the official datasheet [On Request]. The unit suits indoor switchgear panels where a three-phase integrated CT with independent dimension design is required.
Never open-circuit the secondary while the primary is energized. Before commissioning, verify insulation resistance, polarity and ratio. Custom outgoing-wire parameters and secondary burden or winding configurations are available; consult the factory for documentation and delivery.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.