Square epoxy cast zero sequence current transformer for 10kV systems. Available in Φ80 to Φ200 inner diameter specifications. Product performance complies with GB/T 20840.1, 2 and IEC 61869-1, 2. Primary main insulation guaranteed by cable, secondary winding tested. Secondary winding withstands 3kV power frequency voltage to ground for 1 minute. Square epoxy resin cast construction, compact design, easy installation. Used for ground fault protection in medium voltage systems.
Zero sequence CT for 10kV systems, ideal for earth fault protection in MV networks. Suitable for cable diameters Φ80-Φ200.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 61869-1,2, GB/T 20840.1,2 |
| Model Code | CSJK-80-200 | Factory nameplate marking |
| Primary Voltage | 10kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 61869-1,2, GB/T 20840.1,2 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Square epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
For zero sequence CT, connect the primary cable through the window. The secondary terminals are S1 and S2. Ensure the secondary is connected to a protective relay or burden. Never open-circuit the secondary of a CT while energized - hazardous voltage. Ground the secondary winding at one point. For earth fault protection, the CT is typically connected in residual connection with other phase CTs or used as a core-balance CT. Refer to IEC 61869-2 for terminal markings and safety.
Compliant with: IEC 61869-1,2, GB/T 20840.1,2
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this CT?
A: The primary voltage is 10kV, and the secondary winding withstands 3kV power frequency voltage to ground for 1 minute. The primary insulation is guaranteed by the cable.
Q: Can this CT be used for metering?
A: No, it is designed for earth fault protection, not for metering or revenue purposes.
Q: What is the inner diameter range?
A: The inner diameter ranges from Φ80 to Φ200, accommodating various cable sizes.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated current ratio (A) | Accuracy class | Rated output (VA) | Rated current ratio (A) | Accuracy class | Rated output (VA) |
|---|---|---|---|---|---|---|
| CSJK-Φ80 CSJK-Φ100 | 50-60/1 | 10P5 | 2.5 | — | — | — |
| 75/1 | 10P5 | 3.75 | 75/5 | 10P5 | 2.5 | |
| 100/1 | 10P10(10P5) | 2.5(5) | 100/5 | 10P10(10P5) | 1.5(3.75) | |
| 150/1 | 10P10(10P5) | 3.75(7.5) | 150/5 | 10P10(10P5) | 2.5(7.5) | |
| 200-300/1 | 10P10(10P5) | 5(10) | 250-300/5 | 10P10(10P5) | 5(10) | |
| 400-600/1 | 10P10(10P5) | 5(10) | 400-600/5 | 10P10(10P5) | 5(10) | |
| CSJK-Φ120 CSJK-Φ160 CSJK-Φ200 | 50-60/1 | 10P5 | 3.75 | — | — | — |
| 75/1 | 10P10(10P5) | 3.75(7.5) | 75/5 | 10P5 | 2.5 | |
| 100/1 | 10P10(10P5) | 7.5(15) | 100/5 | 10P10(10P5) | 3.75(7.5) | |
| 150/1 | 10P10(10P5) | 10(20) | 150/5 | 10P10(10P5) | 5(10) | |
| 200-300/1 | 10P10(10P5) | 10(20) | 250-300/5 | 10P10(10P5) | 7.5(15) | |
| 400-600/1 | 10P10(10P5) | 10(20) | 400-600/5 | 10P10(10P5) | 7.5(15) |
Dimension & outline drawing of CSJK-80-200 — click image to zoom / view original.
The CSJK-Φ80 to Φ200 is a 10kV zero sequence current transformer for earth fault protection, built and tested to IEC 61869-1,2 and GB/T 20840.1,2. Its square dry epoxy resin cast body keeps the footprint compact, so it fits neatly into switchgear cubicles and distribution rooms where panel space is tight and oil-filled or SF6 alternatives would need extra clearance and maintenance.
Accuracy classes are 10P5 and 10P10(10P5), with rated outputs of 2.5VA, 3.75VA, 5VA, 7.5VA and 10VA depending on the ratio selected. The dry epoxy insulation removes the oil-handling and gas-monitoring routines that oil-immersed and SF6 designs demand, which suits projects prioritising low maintenance. Type and routine test reports are available [On Request] to support compliance verification.
Typical deployment covers earth fault protection in wind, photovoltaic and storage collector substations. Secondary terminals must be wired per the nameplate diagram and earthed at one point; the secondary must never be open-circuited while energised. Do not over-specify a higher accuracy class than the protection scheme needs, as this adds cost without benefit. Ratio and class options, documentation packages and lead times are confirmed at quotation.
Same product family, different ratings — compare before you specify.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1911 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1775 Current Transformer Applied to CGIS Gas Insulated Switchgear is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.
Current Transformer Applied to CGIS Gas Insulated Switchgear
CGIS1780 I Current Transformer Applied to CGIS Gas Insulated Switchgear (CGIS1780-I) is designed for metering and protection in power systems. Key ratings: primary voltage 35kV. Design: Dry Epoxy Resin, 50/60Hz operation.