Outdoor pole-mounted single-phase power transformer for 20kV/15kV systems. 1000/2000/3000VA capacity options. Epoxy resin cast, weather-resistant design. Compliant with IEC 60076 standards. Provides control power for switchgear. Customizable voltage ratio.
Suitable for outdoor pole-mounted switchgear control power in 20kV/15kV systems, with customizable ratio and epoxy resin insulation.
| Parameter | Specification | Verification |
|---|---|---|
| Product Type | Current Transformer | IEC 60076, GB 1094 |
| Model Code | DC1-2-3-20-15 | Factory nameplate marking |
| Primary Voltage | 20kV/15kV | Rated voltage test (IEC 61869-1/3) |
| Secondary Current | [On Request] | Ratio check at rated frequency |
| Accuracy Class | [On Request] | Accuracy test (IEC 61869-2 / IEEE C57.13) |
| Rated Burden | [On Request] | Burden test at rated VA |
| Insulation Type | Dry Epoxy Resin | Dielectric tests per standard |
| Insulation Level (BIL) | [On Request] | Power-frequency & lightning impulse withstand |
| Standards | IEC 60076, GB 1094 | Certified to listed standards |
| Frequency | 50/60Hz | Per IEC 61869-1 |
| Environment | Outdoor pole-mounted single-phase epoxy resin cast | Per datasheet limits |
Ideal For
Not Recommended For
For power transformers, ground the secondary winding at one point. Follow IEC 60076 terminal markings: primary terminals H1/H2, secondary terminals X1/X2. Ensure proper fusing on primary and secondary sides. Never operate with secondary open-circuited if designed for parallel operation; consult manual.
Compliant with: IEC 60076, GB 1094
S_total = ΣS_instrument + I₂² × (ρ × 2L / A)
Q: What is the insulation level of this transformer?
A: The insulation level is not specified in the provided data; please refer to the datasheet or contact us for details.
Q: Can this transformer be used for indoor applications?
A: It is designed for outdoor pole-mounted use; indoor use may require additional enclosure and ventilation.
Q: What are the available capacity options?
A: The description mentions 1000/2000/3000VA options, but these are not listed in the provided specifications; please confirm availability.
Missing fields are marked [On Request] — never fabricated. M2/M5/M6 verification rows follow IEC 61869 / IEEE C57.13 conventions.
| Model | Rated voltage ratio (kV) | Accuracy classCombined | 220V winding rated output (VA) | 100V winding rated output (VA) | Weight (kg) |
|---|---|---|---|---|---|
| DC-1, 2/20 DC-1, 2/15 | 20/0.22 15/0.22 | — | 1000, 2000 | — | 93 |
| DC-1, 2/20 DC-1, 2/15 | 20/0.1/0.22 15/0.1/0.22 | 0.2, 0.5 | 1000, 2000 | 30, 60 | 93 |
| DC-3/20 DC-3/15 | 20/0.22 15/0.22 | — | 3000 | — | 93 |
| DC-3/20 DC-3/15 | 20/0.1/0.22 15/0.1/0.22 | 0.2, 0.5 | 3000 | 30, 60 | 93 |

Dimension & outline drawing of DC1-2-3-20-15 — click image to zoom / view original.
Same product family, different ratings — compare before you specify.
LXK Φ80 to Φ240 Zero Sequence Current Transformer for Earth Fault Protection
Indoor zero sequence current transformer for 35kV and below systems. Used for three-phase cable ground protection in small grounding current systems. Can also be used with relay protection devices. Rated frequency 50Hz or 60Hz. Available in Φ80 to Φ240 inner diameter sizes. Split design with clamp fastening, can be installed without power interruption. Compliant with IEC 61869 and GB/T 20840 standards. Epoxy resin cast construction, suitable for indoor installation.
35kV Indoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV A indoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.
LJZ-Φ75/110/125 10kV Outdoor Three-Phase Integrated Current Transformer with Zero-Sequence for Pole-Mounted Circuit Breaker
Zero sequence current transformer for 35kV and below voltage systems. Used for cable ground protection in small grounding current systems. Rated frequency 50Hz or 60Hz. Available in Φ75, Φ110, Φ125 inner diameter sizes. Primary insulation guaranteed by cable, secondary winding insulation tested. Compliant with IEC 61869 and GB/T 20840 standards. Matching relay model DL-11/0.2, epoxy resin cast construction.
Current Transformer for Inflatable Switchgear
Special current transformer designed for CGIS inflatable switchgear with multiple accuracy grades and abundant primary current specifications; secondary lead length and stacked product height support customized production.
35kV Outdoor Epoxy Cast Post-Type Current Transformer with Protection Winding
35kV W1 outdoor pillar type epoxy resin cast current transformer. Rated insulation level 40.5/95/185kV, 50/60Hz, secondary current 5A or 1A. Multiple accuracy class combinations: 0.2S/0.5S/10P10/10P25. Compliant with IEC 61869 and GB/T 20840 standards. Vacuum epoxy casting, high mechanical strength, excellent insulation performance. Rated primary current 50-1600A, short-time thermal current up to 50kA/4s. Suitable for 35kV power systems, customizable ratio and accuracy.
Current Transformer Applied to CGIS Gas Insulated Switchgear
Indoor epoxy resin casting current transformer designed for CGIS gas insulated switchgear, with multiple accuracy class, rated burden and primary current options.